CoChat

Effect of a Novel Quaternary Ammonium Methacrylate Polymer (QAMP) on Adhesion and Antibacterial Properties of Dental Adhesives

Open access
Pupo, Yasmine, Farago, Paulo, Nadal, Jessica, Simão, Luzia, Esmerino, Luís, Gomes, Osnara, Gomes, João · 2014 · International Journal of Molecular Sciences

The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.

Abstract

This study investigated the resin-dentin bond strength (μTBS), degree of conversion (DC), and antibacterial potential of an innovative adhesive system containing a quaternary ammonium methacrylate polymer (QAMP) using in situ and in vitro assays. Forty-two human third molars were flattened until the dentin was exposed and were randomly distributed into three groups of self-etching adhesive systems: Clearfil™ SE Bond containing 5% QAMP (experimental group), Clearfil™ Protect Bond (positive control) and Clearfil™ SE Bond (negative control). After light curing, three 1 mm-increments of composite resin were bonded to each dentin surface. A total of thirty of these bonded teeth (10 teeth per group) was sectioned to obtain stick-shaped specimens and tested under tensile stress immediately, and after 6 and 12 months of storage in distilled water. Twelve bonded teeth (4 teeth per group) were longitudinally sectioned in a mesio-to-distal direction to obtain resin-bonded dentin slabs. In situ DC was evaluated by micro-Raman spectroscopy. In vitro DC of thin films of each adhesive system was measured using Fourier transform infrared spectroscopy. In vitro susceptibility tests of these three adhesive systems were performed by the minimum inhibitory/minimum bactericidal concentration (MIC/MBC) assays against Streptococcus mutans, Lactobacillus casei, and Actinomyces naeslundii. No statistically significant difference in μTBS was observed between Clearfil™ SE Bond containing 5% QAMP and Clearfil™ SE Bond (p>0.05) immediately, and after 6 and 12 months of water storage. However Clearfil™ Protect Bond showed a significant reduction of μTBS after 12 months of storage (p=0.039). In addition, QAMP provided no significant change in DC after incorporating into Clearfil™ SE Bond (p>0.05). Clearfil™ SE Bond containing 5% QAMP demonstrated MIC/MBC values similar to the positive control against L. casei and A. naeslundii and higher than the negative control for all evaluated bacterial strains. The use of QAMP in an adhesive system demonstrated effective bond strength, a suitable degree of conversion, and adequate antibacterial effects against oral bacteria, and may be useful as a new approach to provide long-lasting results for dental adhesives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijms15058998

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Chemical structure of the quaternary ammonium methacrylate polymer (QAMP) [Brazil patent application number 10 2012 0266 4] [28].
Figure 1. Chemical structure of the quaternary ammonium methacrylate polymer (QAMP) [Brazil patent application number 10 2012 0266 4] [28].CC BY · PubMed Central
Figure 2. Raman spectra of QAMP and raw materials (Eudragit™ E100 and n-octyl bromide). (a1) Raman band at 3030 cm−1 as a broadening of C–H alkyl stretching bands; (a2) A novel band attributed to the symmetric stretching vibration of octyl dimethyl ammonium substituent was verified at 726 cm−1; (b) The C–Br stretching vibration presented in n-octyl bromide between 560 and 650 cm−1 disappeared in QAMP; and (c) Raman bands associated with dimethylamino groups of Eudragit™ E100, previously observed at 2772 and 2821 cm−1 also disappeared.
Figure 2. Raman spectra of QAMP and raw materials (Eudragit™ E100 and n-octyl bromide). (a1) Raman band at 3030 cm−1 as a broadening of C–H alkyl stretching bands; (a2) A novel band attributed to the symmetric stretching vibration of octyl dimethyl ammonium substituent was verified at 726 cm−1; (b) The C–Br stretching vibration presented in n-octyl bromide between 560 and 650 cm−1 disappeared in QAMP; and (c) Raman bands associated with dimethylamino groups of Eudragit™ E100, previously observed at 2772 and 2821 cm−1 also disappeared.CC BY · PubMed Central
Figure 3. Micro-Raman spectras of uncured and cured adhesive systems Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, Clearfil™ SE Bond. The reference band is shown at 1609 cm−1 and the reactive band related to C=C group is indicated at 1639 cm−1 (arrows). This band decreases during polymerization and was used for calculating the degree of conversion.
Figure 3. Micro-Raman spectras of uncured and cured adhesive systems Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, Clearfil™ SE Bond. The reference band is shown at 1609 cm−1 and the reactive band related to C=C group is indicated at 1639 cm−1 (arrows). This band decreases during polymerization and was used for calculating the degree of conversion.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Imazato S. Kawakami M. Torii M. Tsuchitani Y. Antibacterial activity of composites containing chemically bound non-releasing antibacterial component J. Dent. Res 1992 72 721

Cited by

See all 38

Metadata

Authors
Pupo, Y., Farago, P., Nadal, J., Simão, L., Esmerino, L., Gomes, O., & Gomes, J.
Affiliations
  • Universidade Estadual de Ponta Grossa (BR)
  • Laboratory of Pharmaceutical Products, Postgraduate Program in Pharmaceutical Sciences, Department of Pharmaceutical Sciences, State University of Ponta Grossa, Paraná 84030-900, Brazil
  • Postgraduate Program in Dentistry, Department of Dentistry, State University of Ponta Grossa, Paraná 84030-900, Brazil
Corresponding author
Farago, Paulo
Venue
International Journal of Molecular Sciences
Publisher
MDPI AG
Published
2014-05-20
Volume
15
Issue
5
Pages
8998-9015
ISSN
1422-0067 (ISSN-L)
OpenAlex
W2041741714
Cited by
36
References
47
Citations by year
2026: 1 · 2025: 5 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 4 · 2018: 3 · 2017: 6 · 2016: 1 · 2015: 3
FWCI
4.86
Type
journal article
Language
en
Open access
Locations
  • International Journal of Molecular Sciences (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
  • Physical Sciences › Materials Science › General Materials Science › Material Properties and Applications
  • Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
Keywords
dental adhesives, resin-dentin bond strength, degree of conversion, antibacterial properties, self-etch adhesive, Clearfil SE Bond, Clearfil Protect Bond, Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, oral bacteria
MeSH terms
Actinomyces, Quaternary Ammonium Compounds, Dental Bonding, Composite Resins, Dental Cements, Humans, Lacticaseibacillus casei, Materials Testing, Methacrylates, Microbial Sensitivity Tests, Polymers, Streptococcus mutans, Surface Properties, Tensile Strength, Time Factors, Curing Lights, Dental

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.