CoChat

The Use of the Hypotension Prediction Index Integrated in an Algorithm of Goal Directed Hemodynamic Treatment during Moderate and High-Risk Surgery

Open access
Tsoumpa, Marina, Kyttari, Aikaterini, Matiatou, Stamo, Tzoufi, Maria, Griva, Panayota, Pikoulis, Emmanouil, Riga, Maria, Matsota, Paraskevi, Sidiropoulou, Tatiana · 2021 · Journal of Clinical Medicine
Cited by 87

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

(1) Background: The Hypotension Prediction Index (HPI) is an algorithm that predicts hypotension, defined as mean arterial pressure (MAP) less than 65 mmHg for at least 1 min, based on arterial waveform features. We tested the hypothesis that the use of this index reduces the duration and severity of hypotension during noncardiac surgery. (2) Methods: We enrolled adults having moderate- or high-risk noncardiac surgery with invasive arterial pressure monitoring. Participating patients were randomized 1:1 to standard of care or hemodynamic management with HPI guidance with a goal directed hemodynamic treatment protocol. The trigger to initiate treatment (with fluids, vasopressors, or inotropes) was a value of HPI of 85 (range, 0–100) or higher in the intervention group. Primary outcome was the amount of hypotension, defined as time-weighted average (TWA) MAP less than 65 mmHg. Secondary outcomes were time spent in hypertension defined as MAP more than 100 mmHg for at least 1 min; medication and fluids administered and postoperative complications. (3) Results: We obtained data from 99 patients. The median (IQR) TWA of hypotension was 0.16 mmHg (IQR, 0.01–0.32 mmHg) in the intervention group versus 0.50 mmHg (IQR, 0.11–0.97 mmHg) in the control group, for a median difference of −0.28 (95% CI, −0.48 to −0.09 mmHg; p = 0.0003). We also observed an increase in hypertension in the intervention group as well as a higher weight-adjusted administration of phenylephrine in the intervention group. (4) Conclusions: In this single-center prospective study of patients undergoing elective noncardiac surgery, the use of this prediction model resulted in less intraoperative hypotension compared with standard care. An increase in the time spent in hypertension in the treatment group was also observed, probably as a result of overtreatment. This should provide an insight for refining the use of this prediction index in future studies to avoid excessive correction of blood pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jcm10245884

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 87

Metadata

Authors
Tsoumpa, M., Kyttari, A., Matiatou, S., Tzoufi, M., Griva, P., Pikoulis, E., Riga, M., Matsota, P., & Sidiropoulou, T.
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2021-12-15
Volume
10
Issue
24
Pages
5884
ISSN
2077-0383 (ISSN-L)
OpenAlex
W4200286099
Cited by
87
References
3
FWCI
9.96
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.