Electrical Impedance Tomography for Cardio-Pulmonary Monitoring
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frerichs, I., Amato, M. B. P., van Kaam, A. H., Tingay, D. G., Zhao, Z., Grychtol, B., Bodenstein, M., Gagnon, H., Böhm, S. H., Teschner, E., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2016-208357 · Cited by 1,016 · cited 9×
“Commercially available EIT devices use frame rates between 40 and 50 images/s [2], as shown in Table 2.”
BackgroundMethodInfluentialKhalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712 · cited 1×
“It is commonly obtained using four electrodes, where two are used for AC injection and the other two for voltage measurement [3,4].”
MethodComparing Reconstruction Algorithms for Electrical Impedance Tomography
Yorkey, T. J., Webster, J. G., & Tompkins, W. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326032 · Cited by 596 · cited 1×
“Currently, the Sheffield back-projection algorithm [8], the finite element method (FEM) based linearized Newton-Raphson algorithm [9], and the Graz consensus reconstruction algorithm for EIT (GREIT) [10] are frequently used.”
MethodSpontaneous Effort Causes Occult Pendelluft during Mechanical Ventilation
Yoshida, T., Torsani, V., Gomes, S., De Santis, R. R., Beraldo, M. A., Costa, E. L. V., Tucci, M. R., Zin, W. A., Kavanagh, B. P., & Amato, M. B. P. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201303-0539oc · Cited by 575 · cited 3×
“Pendelluft can only be visualized by EIT but not by conventional monitoring of flow, volume, or pressure curves [63].”
BackgroundCosta, E. L. V., Borges, J. B., Melo, A., Suarez-Sipmann, F., Toufen, C., Bohm, S. H., & Amato, M. B. P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1447-y · Cited by 506 · cited 3×
“Lung overdistension is assumed when an increased PEEP results in a lower pixel CRS [30].”
BackgroundMethodInfluentialZhao, Z., Möller, K., Steinmann, D., Frerichs, I., & Guttmann, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1589-y · Cited by 321 · cited 5×
“The GI index, used to titrate PEEP, investigate changes in ventilation distribution, and the progression of obstructive lung disease [37].”
BackgroundMethodInfluentialMauri, T., Alban, L., Turrini, C., Cambiaghi, B., Carlesso, E., Taccone, P., Bottino, N., Lissoni, A., Spadaro, S., Volta, C. A., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4890-1 · Cited by 294 · cited 1×
“[53] studied the effect of ventilatory support using a high-flow nasal cannula (HFNC) in hypoxemic respiratory failure and demonstrated that increasing the HFNC flow rate decreased inspiratory effort and increases end-expiratory lung volume as measured by ∆EELI.”
MethodEnd-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change
Hinz, J., Hahn, G., Neumann, P., Sydow, M., Mohrenweiser, P., Hellige, G., & Burchardi, H. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1555-4 · Cited by 248 · cited 3×
“95) with global ∆EELV which has been determined by spirometric measurements of VT [17,18], multi-breath nitrogen-washout technique [19], CT [20], and electronbeam computed tomography (EBCT) [21].”
BackgroundMethodNestler, C., Simon, P., Petroff, D., Hammermüller, S., Kamrath, D., Wolf, S., Dietrich, A., Camilo, L. M., Beda, A., Carvalho, A. R., et al. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex192 · Cited by 231 · cited 1×
“found that a PEEP strategy which minimizes RVDI indicating an increase in temporal heterogeneity of the lung during a decremental PEEP trial improved gas exchange, lung mechanics, and ventilation distribution in severely obese patients who underwent laparoscopic surgery [54].”
BackgroundBorges, J. B., Suarez-Sipmann, F., Bohm, S. H., Tusman, G., Melo, A., Maripuu, E., Sandström, M., Park, M., Costa, E. L. V., Hedenstierna, G., et al. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01090.2010 · Cited by 222 · cited 10×
“[64] found a correlation of lung perfusion from EIT with SPECT using hypertonic saline (NaCl 20%, 10 mL) in healthy subjects with unilateral lung collapse and injured subjects with bilateral-dependent lung collapse.”
BackgroundMethodInfluentialWrigge, H., Zinserling, J., Muders, T., Varelmann, D., Günther, U., von der Groeben, C., Magnusson, A., Hedenstierna, G., & Putensen, C. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181652edd · Cited by 206 · cited 6×
“The regional ventilation delay (RVD) is an EIT measure that can show a temporal delay in regions of the lung and therefore the temporal heterogeneity occurring in the ventilated lung by the relationship between ∆Z and the ventilation time course in each pixel [20,41].”
BackgroundMethodInfluentialSelf-citationFrerichs, I., Hahn, G., Golisch, W., Kurpitz, M., Burchardi, H., & Hellige, G. (1998) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1998.tb05308.x · Cited by 203 · cited 2×
“Reduced values of the CoV indicate a shift of ventilation distribution towards ventral lung regions, which may be observed during derecruitment due to alveolar collapse in the dependent lung regions [32].”
BackgroundElectrical impedance tomography: the holy grail of ventilation and perfusion monitoring?
Leonhardt, S. K., & Lachmann, B. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2684-z · Cited by 198 · cited 8×
“Capacitance depends on the biomembranes’ characteristics of the tissue such as ion channels, fatty acids, and gap junctions, whereas resistance is mainly determined by the composition and the amount of extracellular fluid [1,2].”
BackgroundMethodInfluentialReal-time detection of pneumothorax using electrical impedance tomography*
Costa, E. L. V., Chaves, C. N., Gomes, S., Beraldo, M. A., Volpe, M. S., Tucci, M. R., Schettino, I. A. L., Bohm, S. H., Carvalho, C. R. R., Tanaka, H., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31816a0380 · Cited by 188 · cited 2×
“EIT has been shown to detect a pneumothorax within three ventilator cycles with 100% sensitivity [56] and to be useful for early bedside detection of pneumothorax in patients with ARDS [57].”
BackgroundMethodMuders, T., Luepschen, H., Zinserling, J., Greschus, S., Fimmers, R., Guenther, U., Buchwald, M., Grigutsch, D., Leonhardt, S., Putensen, C., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318236f452 · Cited by 169 · cited 4×
“However, previous research [41] demonstrated that a slow inflation maneuver is mandatory for sufficient RVDI calculation and assessment of tidal recruitment.”
BackgroundMethodInfluentialSelf-citationRegional Ventilation by Electrical Impedance Tomography
Hinz, J. M., Neumann, P., Dudykevych, T., Andersson, L. G., Wrigge, H., Burchardi, H., & Hedenstierna, G. (2003) · CHEST Journal · doi:10.1378/chest.124.1.314 · Cited by 168 · cited 7×
“While there has been a sufficient correlation between EIT and SPECT for both ventilation and perfusion, we observed a spatial mismatch between ventilation and perfusion which might spoil the pixel-wise calculation of regional V/Q.”
BackgroundInfluentialChanges in the thoracic impedance distribution under different ventilatory conditions
Hahn, G., Šipinková, I., Baisch, F. J., & Hellige, G. (1995) · Physiological Measurement · doi:10.1088/0967-3334/16/3a/016 · Cited by 166
Franchineau, G., Bréchot, N., Lebreton, G., Hekimian, G., Nieszkowska, A., Trouillet, J.-L., Leprince, P., Chastre, J., Luyt, C.-E., Combes, A., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-1055oc · Cited by 166 · cited 1×
“ODLC measurements were also used to individually titrate PEEP in ARDS patients during ultra-protective mechanical ventilation (using a VT of 4 mL/kg BW or below) who underwent extra corporeal membrane oxygenation [52].”
MethodPohlman, M. C., McCallister, K., Schweickert, W. D., Pohlman, A. S., Nigos, C., Krishnan, J. A., Charbeneau, J., Gehlbach, B. K., Kress, J. P., & Hall, J. B. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31818b308b · Cited by 156 · cited 2×
“Breath stacking may be caused by reverse triggering or double-triggering and results in consecutive inspiratory cycles delivered by the ventilator on top of an incomplete exhalation [62].”
BackgroundSpadaro, S., Mauri, T., Böhm, S. H., Scaramuzzo, G., Turrini, C., Waldmann, A. D., Ragazzi, R., Pesenti, A. M., & Volta, C. A. (2018) · Critical Care · doi:10.1186/s13054-017-1931-7 · Cited by 141 · cited 1×
“NSS might be indicative for overdistension [39], whereas changes in DSS have been shown to correlate with changes in recruited and derecruited lung volume, as measured by the global P-V curve, during incremental and decremental PEEP steps [40].”
MethodZhao, Z., Chang, M.-Y., Chang, M.-Y., Gow, C., Zhang, J., Hsu, Y.-L., Frerichs, I., Chang, H., & Möller, K. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0484-0 · Cited by 128 · cited 1×
“[51] compared individualized PEEP levels which were obtained from ODLC measurements to PEEP levels which were derived from global P/V curves (PEEP 2 cmH2O above LIP) and demonstrated that EIT-based PEEP titration might improve lung mechanics, gas exchange, and weaning success.”
MethodLindgren, S., Hergès, H. O., Olegård, C., Söndergaard, S., Lundin, S., & Stenqvist, O. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0425-x · Cited by 125 · cited 1×
“EIT has been shown to be helpful for localizing and quantifying the loss of lung volume caused by open endotracheal suctioning and to titrate recruitment maneuvers to restore ventilation distribution [60].”
BackgroundTopographic Distribution of Tidal Ventilation in Acute Respiratory Distress Syndrome
Mauri, T., Bellani, G., Confalonieri, A., Tagliabue, P. F., Turella, M., Coppadoro, A., Citerio, G., Patroniti, N. A., & Pesenti, A. M. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318287f6e7 · Cited by 124 · cited 1×
“[50] showed an improved homogeneous ventral-to-dorsal ventilation distribution during assisted ventilation at a high PEEP-level when compared with control mechanical ventilation.”
BackgroundProtective ventilation using electrical impedance tomography
Luepschen, H., Meier, T., Großherr, M., Leibecke, T., Karsten, J., & Leonhardt, S. K. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/7/s18 · Cited by 117 · cited 1×
“Following the definition of the center of gravity (CoG) in mechanics, more recent studies directly calculate a measure similar to the CoV in both dorsal-ventral [33] and right-left direction [34] as the weighted means of the image row or column sums, respectively.”
MethodRegional pressure volume curves by electrical impedance tomography in a model of acute lung injury
Kunst, P. W. A., Böhm, S. H., Anda, G. F. V.-D., Amato, M. B. P., Lachmann, B., Postmus, P. E., & VRIES, P. M. J. M. D. (2000) · Critical Care Medicine · doi:10.1097/00003246-200001000-00029 · Cited by 116 · cited 1×
“Using fEIT images to visualize the regional distribution of LIP and UIP in different lung regions might be a helpful tool to individually titrate PEEP [27,28].”
MethodKarsten, J., Stueber, T., Voigt, N., Teschner, E., & Heinze, H. (2016) · Critical Care · doi:10.1186/s13054-015-1161-9 · Cited by 113 · cited 1×
“To perform EIT measurements, electrodes are placed around the thorax in a transverse plane, usually in the 4th to 5th intercostal spaces (ICS) at the parasternal line [5].”
MethodLung Recruitment in Obese Patients with Acute Respiratory Distress Syndrome
Fumagalli, J., Santiago, R. R. D. S., Droghi, M. T., Zhang, C., Fintelmann, F. J., Troschel, F. M., Morais, C. C. A., Amato, M. B. P., Kacmarek, R. M., Berra, L. M., et al. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002638 · Cited by 103 · cited 2×
“Recently, ODCL-measurements were used to demonstrate that a decremental PEEP titration preceded by a recruitment maneuver obtained the best lung function by decreasing both collapse and overdistension in severely obese ARDS patients [31].”
BackgroundMethodRegional tidal ventilation and compliance during a stepwise vital capacity manoeuvre
Dargaville, P. A., Rimensberger, P. C., & Frerichs, I. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1995-1 · Cited by 102
Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT
Hahn, G., Just, A., Dudykevych, T., et al. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/5/s16 · Cited by 97 · cited 1×
“EIT has been shown to reliably detect the development of pneumothorax at the bedside in real-time [55].”
BackgroundKunst, P. W. A., Anda, G. F. V.-D., Böhm, S. H., Faes, T. J. C., Lachmann, B., Postmus, P. E., & VRIES, P. M. J. M. D. (2000) · Critical Care Medicine · doi:10.1097/00003246-200012000-00025 · Cited by 92 · cited 1×
“The impedance ratio divides the ventilation activity of the ventral region by the dorsal ventilation activity of the fEIT images, and may indicate both lung recruitment and derecruitment [23].”
Grivans, C., Lundin, S., Stenqvist, O., & Lindgren, S. (2011) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2011.02511.x · Cited by 86 · cited 2×
“95) with global ∆EELV which has been determined by spirometric measurements of VT [17,18], multi-breath nitrogen-washout technique [19], CT [20], and electronbeam computed tomography (EBCT) [21].”
MethodUkere, A., März, A., Wodack, K., Trepte, C. J. C., Haese, A., Waldmann, A. D., Böhm, S. H., & Reuter, D. A. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew188 · Cited by 85
Zhao, Z., Pulletz, S., Frerichs, I., Müller-Lisse, U. G., & Möller, K. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-82 · Cited by 84 · cited 2×
“[38] demonstrated that the GI index is a reliable measure of ventilation heterogeneity and highly correlates with recruitment determined using EIT.”
MethodBluth, T., Kiss, T., Kircher, M., Braune, A., Bozsak, C., Huhle, R., Scharffenberg, M., Herzog, M., Roegner, J., Herzog, P., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.04.056 · Cited by 82 · cited 2×
“Currently, the method is established in animal research, but a reduction of the contrast agent concentration might enable a clinical application in patients in the near future [65,67].”
MethodZick, G., Elke, G., Becher, T., Schädler, D., Pulletz, S., Freitag‐Wolf, S., Weiler, N., & Frerichs, I. (2013) · PLoS ONE · doi:10.1371/journal.pone.0072675 · Cited by 75 · cited 1×
“[48] showed that ventilation distribution, regional CRS, and ∆EELI can be used to assess tidal recruitment and end-inspiratory overinflation in patients with ARDS.”
MethodBikker, I. G., Leonhardt, S. K., Miranda, D. R., Bakker, J., & Gommers, D. A. M. P. J. (2010) · Critical Care · doi:10.1186/cc9036 · Cited by 74 · cited 1×
“[47] observed during a decremental PEEP trial in patients with and without ARDS, that ventilation distribution change maps (∆fEIT maps) can visualize gain or loss of regional ventilation in dependent and non-dependent lung areas at the bedside.”
BackgroundPulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT images
Zadehkoochak, M., Blott, B. H., Hames, T. K., & George, R. F. (1992) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/13/a/037 · Cited by 70
Determination of stroke volume by means of electrical impedance tomography
Noordegraaf, A. V., Janse, A., Marcus, J. T., Bronzwaer, J. G. F., Postmus, P. E., Faes, T. J. C., & VRIES, P. M. J. M. D. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/308 · Cited by 69 · cited 1×
“Stroke volume estimation using the CRS has been explored in animal [82] and human [76,83] studies.”
MethodInformation Processing in Medical Imaging
Bacharach, S. L. (1986) · Springer eBooks · doi:10.1007/978-94-009-4261-5 · Cited by 68
Vogt, B., Zhao, Z., Zabel, P., Weiler, N., & Frerichs, I. (2016) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00463.2015 · Cited by 67
Karagiannidis, C., Waldmann, A. D., Róka, P. L., Schreiber, T., Straßmann, S. E., Windisch, W., & Böhm, S. H. (2018) · Critical Care · doi:10.1186/s13054-018-2137-3 · Cited by 62
Scaramuzzo, G., Spadaro, S., Waldmann, A. D., Böhm, S. H., Ragazzi, R., Marangoni, E., Alvisi, V., Spinelli, E., Mauri, T., & Volta, C. A. (2019) · Critical Care · doi:10.1186/s13054-019-2417-6 · Cited by 60
Hinz, J. M., Moerer, O., Neumann, P., Dudykevych, T., Frerichs, I., Hellige, G., & Quintel, M. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.00958.x · Cited by 59 · cited 1×
“Using fEIT images to visualize the regional distribution of LIP and UIP in different lung regions might be a helpful tool to individually titrate PEEP [27,28].”
MethodReinius, H., Borges, J. B., Fredén, F., Jidéus, L., de Camargo, E. D. L. B., Amato, M. B. P., Hedenstierna, G., LARSSON, A., & Lennmyr, F. (2015) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12455 · Cited by 58 · cited 1×
“[70] investigated regional ventilation and perfusion with EIT using hypertonic saline (NaCl 20%, 5 mL) during one-lung ventilation (OLV) at two different PEEP levels (5 and 10 cmH2O).”
MethodBraun, F., Proença, M., Adler, A., Riedel, T., Thiran, J., & Solà, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191870 · Cited by 53 · cited 2×
“Stroke volume estimation using the CRS has been explored in animal [82] and human [76,83] studies.”
MethodBecher, T., Bußmeyer, M., Lautenschläger, I., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.02.030 · Cited by 39 · cited 1×
“These “out of phase impedance changes” have been attributed to pleural effusion by Becher and co-workers [58].”
BackgroundAssessment of Lung Recruitment by Electrical Impedance Tomography and Oxygenation in ARDS Patients
Yun, L., He, H., Möller, K., Frerichs, I., Liu, D., & Zhao, Z. (2016) · Medicine · doi:10.1097/md.0000000000003820 · Cited by 38
Methods of cardiac gating applied potential tomography
Eyüboğlu, B. M., & Brown, B. H. (1988) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/9/4a/008 · Cited by 36 · cited 1×
“For an ECG gating [75,76], a synchronously recorded ECG is used as a trigger to average a high number (e.”
MethodMorais, C. C. A., Santiago, R. R. D. S., Filho, J. R. B. D. O., Hirota, A. S., Pacce, P. H. D., Ferreira, J. C., de Camargo, E. D. L. B., Amato, M. B. P., & Costa, E. L. V. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201609-1780le · Cited by 33 · cited 17×
“In patients with and without ARDS, Zhao et al. [38] demonstrated that the GI index is a reliable measure of ventilation heterogeneity and highly correlates with recruitment determined using EIT.”
MethodInfluentialPosada-Quintero, H. F., Reljin, N., Eaton-Robb, C., Noh, Y., Riistama, J. M., & Chon, K. H. (2018) · Sensors · doi:10.3390/s18061719 · Cited by 24
A Modified Method to Assess Tidal Recruitment by Electrical Impedance Tomography
Muders, T., Hentze, B., Simon, P., Girrbach, F. F., Doebler, M., Leonhardt, S. K., Wrigge, H., & Putensen, C. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8081161 · Cited by 18 · cited 1×
“Recently, it was demonstrated that the low inflation tidal volume during RVDI measurements can be reduced to 6–9 mL/kgBW [42].”
BackgroundSelf-citation
Metadata
- Authors
- Putensen, C., Hentze, B., Muenster, S., & Muders, T.
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2019-08-07
- Volume
- 8
- Issue
- 8
- Pages
- 1176
- ISSN
- 2077-0383 (ISSN-L)
- OpenAlex
- W2965386100
- Cited by
- 160
- References
- 51
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.