CoChat

Clinical Validation of a Deep Learning Algorithm for Detection of Pneumonia on Chest Radiographs in Emergency Department Patients with Acute Febrile Respiratory Illness

Open access
Kim, Jae Hyun, Kim, Jin Young, Kim, Gun Ha, Kang, Donghoon, Kim, In Jung, Seo, Jeongkuk, Andrews, Jason R., Park, Chang Min · 2020 · Journal of Clinical Medicine
Cited by 42

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Early identification of pneumonia is essential in patients with acute febrile respiratory illness (FRI). We evaluated the performance and added value of a commercial deep learning (DL) algorithm in detecting pneumonia on chest radiographs (CRs) of patients visiting the emergency department (ED) with acute FRI. This single-centre, retrospective study included 377 consecutive patients who visited the ED and the resulting 387 CRs in August 2018–January 2019. The performance of a DL algorithm in detection of pneumonia on CRs was evaluated based on area under the receiver operating characteristics (AUROC) curves, sensitivity, specificity, negative predictive values (NPVs), and positive predictive values (PPVs). Three ED physicians independently reviewed CRs with observer performance test to detect pneumonia, which was re-evaluated with the algorithm eight weeks later. AUROC, sensitivity, and specificity measurements were compared between “DL algorithm” vs. “physicians-only” and between “physicians-only” vs. “physicians aided with the algorithm”. Among 377 patients, 83 (22.0%) had pneumonia. AUROC, sensitivity, specificity, PPV, and NPV of the algorithm for detection of pneumonia on CRs were 0.861, 58.3%, 94.4%, 74.2%, and 89.1%, respectively. For the detection of ‘visible pneumonia on CR’ (60 CRs from 59 patients), AUROC, sensitivity, specificity, PPV, and NPV were 0.940, 81.7%, 94.4%, 74.2%, and 96.3%, respectively. In the observer performance test, the algorithm performed better than the physicians for pneumonia (AUROC, 0.861 vs. 0.788, p = 0.017; specificity, 94.4% vs. 88.7%, p < 0.0001) and visible pneumonia (AUROC, 0.940 vs. 0.871, p = 0.007; sensitivity, 81.7% vs. 73.9%, p = 0.034; specificity, 94.4% vs. 88.7%, p < 0.0001). Detection of pneumonia (sensitivity, 82.2% vs. 53.2%, p = 0.008; specificity, 98.1% vs. 88.7%; p < 0.0001) and ‘visible pneumonia’ (sensitivity, 82.2% vs. 73.9%, p = 0.014; specificity, 98.1% vs. 88.7%, p < 0.0001) significantly improved when the algorithm was used by the physicians. Mean reading time for the physicians decreased from 165 to 101 min with the assistance of the algorithm. Thus, the DL algorithm showed a better diagnosis of pneumonia, particularly visible pneumonia on CR, and improved diagnosis by ED physicians in patients with acute FRI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jcm9061981

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Kim, J. H., Kim, J. Y., Kim, G. H., Kang, D., Kim, I. J., Seo, J., Andrews, J. R., & Park, C. M.
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2020-06-24
Volume
9
Issue
6
Pages
1981
ISSN
2077-0383 (ISSN-L)
OpenAlex
W3036941862
Cited by
42
References
6
FWCI
3.25
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.