The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Many individuals with tinnitus report experiencing hyperacusis (enhanced sensitivity to sounds). However, estimates of the association between hyperacusis and tinnitus is lacking. Here, we investigate this relationship in a Swedish study. A total of 3645 participants (1984 with tinnitus and 1661 without tinnitus) were enrolled via LifeGene, a study from the general Swedish population, aged 18–90 years, and provided information on socio-demographic characteristics, as well as presence of hyperacusis and its severity. Tinnitus presence and severity were self-reported or assessed using the Tinnitus Handicap Inventory (THI). Phenotypes of tinnitus with (n = 1388) or without (n = 1044) hyperacusis were also compared. Of 1661 participants without tinnitus, 1098 (66.1%) were women and 563 were men (33.9%), and the mean (SD) age was 45.1 (12.9). Of 1984 participants with tinnitus, 1034 (52.1%) were women and 950 (47.9%) were men, and the mean (SD) age was 47.7 (14.0) years. Hyperacusis was associated with any tinnitus [Odds ratio (OR) 3.51, 95% confidence interval (CI) 2.99–4.13], self-reported severe tinnitus (OR 7.43, 95% CI 5.06–10.9), and THI ≥ 58 (OR 12.1, 95% CI 7.06–20.6). The association with THI ≥ 58 was greater with increasing severity of hyperacusis, the ORs being 8.15 (95% CI 4.68–14.2) for moderate and 77.4 (95% CI 35.0–171.3) for severe hyperacusis. No difference between sexes was observed in the association between hyperacusis and tinnitus. The occurrence of hyperacusis in severe tinnitus is as high as 80%, showing a very tight relationship. Discriminating the pathophysiological mechanisms between the two conditions in cases of severe tinnitus will be challenging, and optimized study designs are necessary to better understand the mechanisms behind the strong relationship between hyperacusis and tinnitus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jcm9082412

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 99

Metadata

Authors
Cederroth, C., Lugo, A., Edvall, N., Lazar, A., Lopez-Escamez, J.-A., Bulla, J., Uhlen, I., Hoare, D., Baguley, D., Canlon, B., & Gallus, S.
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2020-07-28
Volume
9
Issue
8
Pages
2412
ISSN
2077-0383 (ISSN-L)
OpenAlex
W3045802470
Cited by
99
References
12
FWCI
3.70
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association between Hyperacusis and Tinnitus. https://app.cochat.ai/papers/10.3390/jcm9082412
The paper
Cederroth, C., Lugo, A., Edvall, N., Lazar, A., Lopez-Escamez, J.-A., Bulla, J., Uhlen, I., Hoare, D., Baguley, D., Canlon, B., & Gallus, S. (2020). Association between Hyperacusis and Tinnitus. Journal of Clinical Medicine. https://doi.org/10.3390/jcm9082412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.