The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
The Use of Thermal Techniques for the Characterization and Selection of Natural Biomaterials
Open accessAbstract
In this paper we explore the ability of thermal analysis to check elastin and collagen integrity in different biomaterial applications. Differential Scanning Calorimetry (DSC) has been used to analyze the first and second order transitions of the biological macromolecules in the hydrated and dehydrated state. First, we report the characterization of control cardiovascular tissues such as pericardium, aortic wall and valvular leaflet. Their thermal properties are compared to pure elastin and pure collagen. Second, we present results obtained on two collagen rich tissues: pericardia with different chemical treatments and collagen with physical treatments. Finally, more complex cardiovascular tissues composed of elastin and collagen are analyzed and the effect of detergent treatment on the physical structure of collagen and elastin is brought to the fore.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This behavior is consistent with the chemical modification of amino acid residues involved in stabilizing the triple-helical structure, leading to decreased cooperativity during thermal denaturation and enhanced molecular mobility [42].”
From Montmorillonite-reinforced methacrylated collagen/methacrylated silk fibroin hydrogel-based inks: rheological and physicochemical characterization for bone scaffold applications (2026) · cites this paper as [42]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stability of proteins. Proteins which do not present a single cooperative system.
Privalov, P. L. (1982) · PubMed · Cited by 1,035
Desmet, T., Morent, R., Geyter, N. D., Leys, C., Schacht, E. H., & Dubruel, P. (2009) · Biomacromolecules · doi:10.1021/bm900186s · Cited by 692
Elastin: molecular description and function
Debelle, L., & Tamburro, A. M. (1999) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/s1357-2725(98)00098-3 · Cited by 545
Carboxypeptidase A: A Protein and an Enzyme
Quiocho, F. A., & Lipscomb, W. N. (1971) · Advances in protein chemistry · doi:10.1016/s0065-3233(08)60278-8 · Cited by 400
The Structure Of Collagen And Gelatin
Harrington, W. F., & von Hippel, P. H. (1962) · Advances in protein chemistry · doi:10.1016/s0065-3233(08)60028-5 · Cited by 400
Chemically modified collagen: A natural biomaterial for tissue replacement
Nimni, M. E., Cheung, D. T., Strates, B. S., Kodama, M., & Sheikh, K. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210606 · Cited by 393
Courtman, D. W., Pereira, C. A., Kashef, V., McComb, D., Lee, J. M., & Wilson, G. J. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280602 · Cited by 322
The elastic properties of elastin
Hoeve, C. A. J., & Flory, P. J. (1974) · Biopolymers · doi:10.1002/bip.1974.360130404 · Cited by 313
Heart Valve Tissue Engineering
Veselý, I. (2005) · Circulation Research · doi:10.1161/01.res.0000185326.04010.9f · Cited by 309
Gas Plasma: Medical Uses and Developments in Wound Care
Lloyd, G., Friedman, G., Jafri, S., Schultz, G., Fridman, A., & Harding, K. G. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900097 · Cited by 301
Flagged first, then by citations
1 of the 53 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- Comper, 1996, Arterial Wall, Extracellular Matrix, 1, 175
- Ward, A.G., and Courts, A. (1977). The Science and Technology of Gelatin, Academic Press.
Cited by
Sorted by citations
Items 101–110 of 110
Jalali, S., Khiabani, M. J., Kruppke, I., Heinemann, C., Lee, P. S., Wiesmann, H., Varghese, O. P., & Kruppke, B. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.115249
Biyouyumlu Kolajen /PVA /TiO2 Nanokompozit Filmlerden 5-FU Kanser İlacının Salımı
Coşkuner, T. Ş., & Çakıcı, G. T. (2025) · Gazi Üniversitesi Fen Bilimleri Dergisi Part C Tasarım ve Teknoloji · doi:10.29109/gujsc.1695109
Fundamentals of biobased materials
Agarwalla, A., Kaushik, S., & Prasad, B. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36538-6.00005-x
Liston, L. S., Nuanjan, N., Sawatdee, S., Nisoa, M., Rathore, V., Sugibayashi, K., & Sakdiset, P. (2026) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2026.104275
Assessment of Bovine Collagen Manufactured via Cellular Agriculture
Ahmed, N., Goodwin, C. M., Hales, M., Camacho, J., Gilchrist, C., & Shirwaiker, R. A. (2026) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c02203
Rejeb, M., Lahmar, A., Selmi, A., Kosksi, T., Debbabi, N., Degobert, G., & Ghédira, L. C. (2026) · Journal of Applied Polymer Science · doi:10.1002/app.71498
Greco, G. H., Formenton, G., Delgrosso, E., Morganti, S., Auricchio, F., & Conti, M. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7614858
Metadata
- Authors
- Samouillan, V., Delaunay, F., Dandurand, J., Merbahi, N., Gardou, J.-P., Yousfi, M., Gandaglia, A., Spina, M., & Lacabanne, C.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- University of Padua (IT)
- Physique des Polymères, Institut Carnot CIRIMAT UMR5085, Université Paul Sabatier, 118 route de Narbonne, Bat 3R1B2, 31062 Toulouse Cedex, France
- Corresponding author
- Samouillan, Valérie
- ORCID
- Venue
- Journal of Functional Biomaterials
- Publisher
- MDPI AG
- Published
- 2011-09-13
- Volume
- 2
- Issue
- 3
- Pages
- 230-248
- ISSN
- 2079-4983 (ISSN-L)
- PMC
- PMC4030942
- OpenAlex
- W1978595130
- Cited by
- 111
- References
- 53
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 3 · 2023: 9 · 2022: 7 · 2021: 11 · 2020: 12 · 2019: 14 · 2018: 10 · 2017: 9 · 2016: 4 · 2015: 5 · 2014: 8 · 2013: 3 · 2012: 2
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Functional Biomaterials (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Open Archive Toulouse Archive Ouverte (University of Toulouse) (acceptedVersion, other-oa)
- HAL (submittedVersion, other-oa)
- HAL (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- elastin, collagen, thermal analysis, differential scanning calorimetry, cardiovascular tissue, pericardium, aortic wall, collagen denaturation, detergent treatment, biomaterial selection, biomaterial characterization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review