Evaluation of the Release Kinetics of a Pharmacologically Active Substance from Model Intra-Articular Implants Replacing the Cruciate Ligaments of the Knee
Open accessAbstract
Implants are readily applied as a convenient method of therapy. There is great interest in the prolonged release of active substances from implants. The objective of this work was to evaluate the dissolution kinetics of steroidal anti-inflammatory preparation (SAP) released from novel implants, and to test the influence of the technology on SAP release kinetics. The proposed long-acting preparations may overcome difficulties resulting from repeated injections and often visits to ambulatory clinic, as the stabilizing function of the artificial ligament would be enriched with pharmacological activity. The potential advantages provided by the new coatings of knee implants include the continuous, sustained, and prolonged release of an active substance. The study was carried out using a modified United States Pharmacopoeia (USP) apparatus 4. The amount of SAP was measured spectroscopically. It was revealed that the transport of the drug was mainly a diffusion process. The drug release kinetics was analyzed using zero-, first-, and second-order kinetics as well as Korsmeyer-Peppas, Higuchi, and Hixon-Crowell models. The highest values of the release rate constants were k0 = (7.49 ± 0.05) × 10−5 mg × min−1, k1 = (6.93 ± 0.05) × 10−6 min−1, and k2 = (7.70 ± 0.05) × 10−7 mg−1 × min−1 as calculated according to zero-, first-, and second-order kinetics equations, respectively. The values of the rate constants obtained for the slowest process were k0 = (3.63 ± 0.06) × 10−5 mg × min−1, k1 = (2.50 ± 0.03) × 10−6 min−1, and k2 = (2.80 ± 0.03) × 10−7 mg−1 × min−1. They may suggest the possibility of sustained release of betamethasone from the system. Due to the statistical analysis, differences were observed between most of the studied implants. Incubation, temperature, time of stabilization of layers, and the method of SAP deposition on the matrix affected the drug release.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and comparison of dissolution profiles
Costa, P., & Sousa Lobo, J. M. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00095-1 · Cited by 5,509
Cited by
Kinetic Modeling to Explain the Release of Medicine from Drug Delivery Systems
Askarizadeh, M., Esfandiari, N., Honarvar, B., Sajadian, S. A., & Azdarpour, A. (2023) · ChemBioEng Reviews · doi:10.1002/cben.202300027 · Cited by 318
Yee Kuen, C., & Masarudin, M. J. (2022) · Molecules · doi:10.3390/molecules27020473 · Cited by 78
Metadata
- Authors
- Wojcik-Pastuszka, D., Krzak, J., Macikowski, B., Berkowski, R., Osiński, B., & Musiał, W.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2019-04-12
- Volume
- 12
- Issue
- 8
- Pages
- 1202
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2936678940
- Cited by
- 192
- References
- 1
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.