The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Non-Precious Electrodes for Practical Alkaline Water Electrolysis
Open accessAbstract
Water electrolysis is a promising approach to hydrogen production from renewable energy sources. Alkaline water electrolyzers allow using non-noble and low-cost materials. An analysis of common assumptions and experimental conditions (low concentrations, low temperature, low current densities, and short-term experiments) found in the literature is reported. The steps to estimate the reaction overpotentials for hydrogen and oxygen reactions are reported and discussed. The results of some of the most investigated electrocatalysts, namely from the iron group elements (iron, nickel, and cobalt) and chromium are reported. Past findings and recent progress in the development of efficient anode and cathode materials appropriate for large-scale water electrolysis are presented. The experimental work is done involving the direct-current electrolysis of highly concentrated potassium hydroxide solutions at temperatures between 30 and 100 °C, which are closer to industrial applications than what is usually found in literature. Stable cell components and a good performance was achieved using Raney nickel as a cathode and stainless steel 316L as an anode by means of a monopolar cell at 75 °C, which ran for one month at 300 mA cm−2. Finally, the proposed catalysts showed a total kinetic overpotential of about 550 mV at 75 °C and 1 A cm−2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent progress in alkaline water electrolysis for hydrogen production and applications
Zeng, K., & Zhang, D. (2010) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2009.11.002 · Cited by 3,611
Cited by
Anion-Exchange Membrane Water Electrolyzers
Du, N., Roy, C., Peach, R., Turnbull, M., Thiele, S., & Bock, C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00854 · Cited by 1,075
Yu, M., Budiyanto, E., & Tüysüz, H. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202103824 · Cited by 771
Water electrolysers with closed and open electrochemical systems
Lagadec, M. F., & Grimaud, A. (2020) · Nature Materials · doi:10.1038/s41563-020-0788-3 · Cited by 749
Durability of anion exchange membrane water electrolyzers
Li, D., Motz, A. R., Bae, C., Fujimoto, C., Yang, G., Zhang, F.-Y., Ayers, K. E., & Kim, Y. S. (2021) · Energy & Environmental Science · doi:10.1039/d0ee04086j · Cited by 601
Impact of impurities on water electrolysis: a review
Becker, H., Murawski, J., Shinde, D. V., Stephens, I. E. L., Hinds, G., & Smith, G. (2023) · Sustainable Energy & Fuels · doi:10.1039/d2se01517j · Cited by 366
Magnier, L., Cossard, G., Martin, V., Pascal, C., Roche, V., Sibert, E., Shchedrina, I., Bousquet, R., Parry, V., & Chatenet, M. (2024) · Nature Materials · doi:10.1038/s41563-023-01744-5 · Cited by 347
What is Next in Anion‐Exchange Membrane Water Electrolyzers? Bottlenecks, Benefits, and Future
Santoro, C., Lavacchi, A., Mustarelli, P., Di Noto, V., Elbaz, L., Dekel, D. R., & Jaouen, F. (2022) · ChemSusChem · doi:10.1002/cssc.202200027 · Cited by 337
Lao, M., Li, P., Jiang, Y., Pan, H., Dou, S. X., & Sun, W. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107231 · Cited by 290
Metadata
- Authors
- Colli, A. N., Girault, H. H., & Battistel, A.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2019-04-24
- Volume
- 12
- Issue
- 8
- Pages
- 1336
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2941973958
- Cited by
- 163
- References
- 1
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.