The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mechanical Properties and In Vitro Behavior of Additively Manufactured and Functionally Graded Ti6Al4V Porous Scaffolds
Open accessAbstract
Functionally graded lattice structures produced by additive manufacturing are promising for bone tissue engineering. Spatial variations in their porosity are reported to vary the stiffness and make it comparable to cortical or trabecular bone. However, the interplay between the mechanical properties and biological response of functionally graded lattices is less clear. Here we show that by designing continuous gradient structures and studying their mechanical and biological properties simultaneously, orthopedic implant design can be improved and guidelines can be established. Our continuous gradient structures were generated by gradually changing the strut diameter of a body centered cubic (BCC) unit cell. This approach enables a smooth transition between unit cell layers and minimizes the effect of stress discontinuity within the scaffold. Scaffolds were fabricated using selective laser melting (SLM) and underwent mechanical and in vitro biological testing. Our results indicate that optimal gradient structures should possess small pores in their core (~900 µm) to increase their mechanical strength whilst large pores (~1100 µm) should be utilized in their outer surface to enhance cell penetration and proliferation. We suggest this approach could be widely used in the design of orthopedic implants to maximize both the mechanical and biological properties of the implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 3×
“, Ti6Al4V and 316 L stainless steel have a modulus of around 110 GPa and 210 GPa [4] respectively, whereas the modulus of cortical bone is in the range of 3–20 GPa [5].”
BackgroundDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705 · cited 2×
“4 GPa [59,60]) and cortical bones (3–20 GPa [5,24]).”
Background
Cited by
Additive manufacturing of functionally graded materials: A review
Zhang, C., Chen, F., Huang, Z., Jia, M., Chen, G., Ye, Y., Lin, Y., Liu, W., Chen, B., Shen, Q., et al. (2019) · Materials Science and Engineering: A · doi:10.1016/j.msea.2019.138209 · Cited by 612
Chen, L.-Y., Liang, S.-X., Liu, Y., & Zhang, L.-C. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100648 · Cited by 603
Mechanical performance of additively manufactured meta-biomaterials
Zadpoor, A. A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.12.038 · Cited by 429
Zhang, X.-Y., Fang, G., Leeflang, S., Zadpoor, A. A., & Zhou, J. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.12.013 · Cited by 277
A review on integration of lightweight gradient lattice structures in additive manufacturing parts
Seharing, A., Azman, A. H., & Abdullah, S. (2020) · Advances in Mechanical Engineering · doi:10.1177/1687814020916951 · Cited by 270
Metadata
- Authors
- Onal, E., Frith, J., Jurg, M., Wu, X., & Molotnikov, A.
- Venue
- Metals
- Publisher
- MDPI AG
- Published
- 2018-03-21
- Volume
- 8
- Issue
- 4
- Pages
- 200
- ISSN
- 2075-4701 (ISSN-L)
- OpenAlex
- W2789409851
- Cited by
- 172
- References
- 2
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.