CoChat

Determination of mercury(II) on a centrifugal microfluidic device using ionic liquid dispersive liquid-liquid microextraction

Open access

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

An integrated centrifugal microfluidic device was developed to preconcentrate and detect hazardous mercury (II) in water with ionic liquid as environmentally friendly extractant. An automatically salt-controlled ionic liquid dispersive liquid–liquid microextraction on a centrifugal microfluidic device was designed, fabricated, and characterized. The entire liquid transport mixing and separation process was controlled by rotation speed, siphon valves, and capillary valves. Still frame images on the rotating device showed the process in detail, revealing the sequential steps of mixing, siphon priming, transportation between chambers, and phase separation. The preconcentration of red dye could be clearly observed with the naked eye. By combining fluorescence probe and microscopy techniques, the device was tested to determine ppb-level mercury (II) in water, and was found to exhibit good linearity and low detection limit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi10080523

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 3D rendering of the three-layer structure of the centrifugal microfluidic disc.
Figure 1 3D rendering of the three-layer structure of the centrifugal microfluidic disc.CC BY · PubMed Central
Figure 2 Illustration of the spinning test system, consisting of a computer controller connected to a stroboscopic imaging system over a servo-controlled spinning platform. The retro-reflective fiber-optic sensor was used to detect disc position to allow strobe synchronization.
Figure 2 Illustration of the spinning test system, consisting of a computer controller connected to a stroboscopic imaging system over a servo-controlled spinning platform. The retro-reflective fiber-optic sensor was used to detect disc position to allow strobe synchronization.CC BY · PubMed Central
Figure 3 Layout of one of the three identical devices on the ionic liquid-dispersive liquid–liquid microextraction (IL-DLLME) disc.
Figure 3 Layout of one of the three identical devices on the ionic liquid-dispersive liquid–liquid microextraction (IL-DLLME) disc.CC BY · PubMed Central
Figure 4 Photomicrograph of a sealed capillary valve embedded inside an assembled disc.
Figure 4 Photomicrograph of a sealed capillary valve embedded inside an assembled disc.CC BY · PubMed Central
Figure 5 Spinning protocol in one salt-controlled ionic liquid dispersive liquid-liquid microextraction (SC-IL-DLLME) process.
Figure 5 Spinning protocol in one salt-controlled ionic liquid dispersive liquid-liquid microextraction (SC-IL-DLLME) process.CC BY · PubMed Central
Figure 6 (Top) Schematics of salt-controlled ionic liquid dispersive liquid-liquid microextraction (SC-IL-DLLME) dye solution in operation (ionic liquid, white; NaClO4 solution, yellow). (Bottom) Corresponding experimental stroboscopic images of SC-IL-DLLME dye solution on the disc (ionic liquid, colorless; NaClO4 solution, colorless). The different panels are: (a) loading ionic liquid (IL), NaClO4 and dye (red), mixing IL and dye; (b) priming Siphon Valve 1, transporting from the mixing chamber to the separation chamber, (c) mixing IL and NaClO4, dispersing IL micro droplets; (d) centrifugation and depositing IL in the separation chamber, (e) priming Siphon Valve 2, transporting supernatant (pink) from the separation chamber to the waste chamber, and (f) bursting Capillary Valve 3, transporting enriched IL (dark red) phase from the separation chamber to the detection chamber.
Figure 6 (Top) Schematics of salt-controlled ionic liquid dispersive liquid-liquid microextraction (SC-IL-DLLME) dye solution in operation (ionic liquid, white; NaClO4 solution, yellow). (Bottom) Corresponding experimental stroboscopic images of SC-IL-DLLME dye solution on the disc (ionic liquid, colorless; NaClO4 solution, colorless). The different panels are: (a) loading ionic liquid (IL), NaClO4 and dye (red), mixing IL and dye; (b) priming Siphon Valve 1, transporting from the mixing chamber to the separation chamber, (c) mixing IL and NaClO4, dispersing IL micro droplets; (d) centrifugation and depositing IL in the separation chamber, (e) priming Siphon Valve 2, transporting supernatant (pink) from the separation chamber to the waste chamber, and (f) bursting Capillary Valve 3, transporting enriched IL (dark red) phase from the separation chamber to the detection chamber.CC BY · PubMed Central
Figure 7 Conceptual illustration of the salt-controlled ionic liquid dispersive liquid-liquid microextraction fluorescence detection (SC-IL-DLLME-FD) process steps: (a) The mercury solution dissolved ionic liquid (IL), achieving saturated IL aqueous solution. (b) NaClO4 was added. (c) IL micro-droplets suspended in the emulsion. (d) Centrifugation. (e) Separation. (f) IL phase was mixed with acetonitrile (ACN) and aqueous solution containing para-position tetraphenylethenerhodamine (PTR) probe. (g) Reaction at 55 °C for one hour. (h) Mercury ion was quantified through fluorescence microscope. (i) Resulting fluorescent images.
Figure 7 Conceptual illustration of the salt-controlled ionic liquid dispersive liquid-liquid microextraction fluorescence detection (SC-IL-DLLME-FD) process steps: (a) The mercury solution dissolved ionic liquid (IL), achieving saturated IL aqueous solution. (b) NaClO4 was added. (c) IL micro-droplets suspended in the emulsion. (d) Centrifugation. (e) Separation. (f) IL phase was mixed with acetonitrile (ACN) and aqueous solution containing para-position tetraphenylethenerhodamine (PTR) probe. (g) Reaction at 55 °C for one hour. (h) Mercury ion was quantified through fluorescence microscope. (i) Resulting fluorescent images.CC BY · PubMed Central
Figure 8 Schematics of the custom-built heating apparatus.
Figure 8 Schematics of the custom-built heating apparatus.CC BY · PubMed Central
Figure 9 The fluorescence (FL) intensity as a function of the concentration of Hg2+.
Figure 9 The fluorescence (FL) intensity as a function of the concentration of Hg2+.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 15

Metadata

Authors
Hui, Y., Liu, Y., Tang, W. C., Song, D., Madou, M., Xia, S., & Wu, T.
Affiliations
  • Chinese Academy of Sciences (CN)
  • University of California, Irvine (US)
Corresponding author
Wu, Tianzhun
Venue
Micromachines
Publisher
MDPI AG
Published
2019-08-08
Volume
10
Issue
8
Pages
523
ISSN
2072-666X (ISSN-L)
OpenAlex
W2968175262
Cited by
15
References
24
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 2
FWCI
1.26
Type
journal article
Language
en
Open access
Locations
  • Micromachines (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • Major State Basic Research Development Program of China (No. 2015CB352100)
  • China Scholarship Council (No. 201704910667)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
Keywords
mercury(II) detection, ionic liquids, dispersive liquid-liquid microextraction, preconcentration, water analysis, fluorescent probes, capillary valves, phase separation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.