Determination of mercury(II) on a centrifugal microfluidic device using ionic liquid dispersive liquid-liquid microextraction
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
An integrated centrifugal microfluidic device was developed to preconcentrate and detect hazardous mercury (II) in water with ionic liquid as environmentally friendly extractant. An automatically salt-controlled ionic liquid dispersive liquid–liquid microextraction on a centrifugal microfluidic device was designed, fabricated, and characterized. The entire liquid transport mixing and separation process was controlled by rotation speed, siphon valves, and capillary valves. Still frame images on the rotating device showed the process in detail, revealing the sequential steps of mixing, siphon priming, transportation between chambers, and phase separation. The preconcentration of red dye could be clearly observed with the naked eye. By combining fluorescence probe and microscopy techniques, the device was tested to determine ppb-level mercury (II) in water, and was found to exhibit good linearity and low detection limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Finally, an approach to automation of IL-DLLME of metals has been recently proposed by Hui et al. (2019), based on the use of a centrifugal microfluidic disk to enrich and detect Hg in water samples [65].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Currie, L. A. (1995) · Pure and Applied Chemistry · doi:10.1351/pac199567101699 · Cited by 1,703 · cited 1×
“According to the IUPAC recommendation [25], the limit of detection (LOD) and the limit of quantitation (LOQ) were calculated as the concentration yielding a peak area equal to the blank signal plus 3- and 10-times the blank standard deviation, respectively.”
MethodVentura, S. P. M., e Silva, F. A., Quental, M. V., Mondal, D., Freire, M. G., & Coutinho, J. A. P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00550 · Cited by 1,024 · cited 1×
“Ionic liquids (ILs), as environmentally friendly extractants, play increasingly important roles in extracting a large amount of bioactive compounds [11].”
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731 · cited 1×
“Microfluidic devices offer attractive alternatives for sample separation, detection, and analysis because of their inherent cost-effective fabrication process, requiring small sample size due to miniaturization, and amenable to automation by integrating multiple functions on the same platform [13,14].”
Self-citationMethods for the determination and speciation of mercury in natural waters—A review
Leopold, K., Foulkes, M., & Worsfold, P. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.048 · Cited by 497 · cited 1×
“Trace mercury(II) (Hg2+) contamination in water is highly hazardous to the environment in general and particularly to human health [1].”
Centrifugal microfluidic platforms: advanced unit operations and applications
Strohmeier, O., Keller, M., Schwemmer, F., Zehnle, S., Mark, D., von Stetten, F., Zengerle, R., & Paust, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00371c · Cited by 463
Speciation of mercury in water and fish samples by HPLC-ICP-MS after magnetic solid phase extraction
Zhu, S., Chen, B., He, M., Huang, T., & Hu, B. (2017) · Talanta · doi:10.1016/j.talanta.2017.04.068 · Cited by 185 · cited 1×
“Conventional approaches to detect trace Hg2+ such as atomic fluorescence spectrometry (AFS) [3,4] and inductively coupled plasma mass spectrometry (ICP-MS) [5] require very expensive, complex, and bulky instruments.”
BackgroundLab-on-a-CD: A Fully Integrated Molecular Diagnostic System
Kong, L. X., Perebikovsky, A., Moebius, J., Kulinsky, L., & Madou, M. J. (2015) · SLAS TECHNOLOGY · doi:10.1177/2211068215588456 · Cited by 121
Self-citationStanisz, E., Werner, J., & Zgoła-Grześkowiak, A. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.008 · Cited by 116
Large-Volume Centrifugal Microfluidic Device for Blood Plasma Separation
Amasia, M., & Madou, M. J. (2010) · Bioanalysis · doi:10.4155/bio.10.140 · Cited by 116 · cited 1×
“When the spinning speed decreased to a low enough speed, the capillary force overcame the centrifugal force, and surface tension pulled the meniscus over the crest [24], bringing the liquid through the hydrophilic siphon channel.”
Self-citationEl-Shahawi, M. S., & Al‐Saidi, H. M. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.10.011 · Cited by 111 · cited 1×
“As a result, DLLME has been widely used for the determination of trace-concentration substances [10].”
Ferreira, S. L. C., Lemos, V. A., Silva, L. O. B., Queiroz, A. F. D. S., Souza, A. S., da Silva, E. G. P., dos Santos, W. N. L., & das Virgens, C. F. (2015) · Microchemical Journal · doi:10.1016/j.microc.2015.02.012 · Cited by 105
Sajid, M. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.07.009 · Cited by 84 · cited 1×
“Compared with LLE, dispersive liquid-liquid microextraction (DLLME) is advantageous because of the simplicity in its operations, high enrichment factor, and small amount of solvents requirement [9].”
Liu, Y.-M., Zhang, F., Jiao, B.-Y., Rao, J.-Y., & Leng, G. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.03.002 · Cited by 79 · cited 1×
“Conventional approaches to detect trace Hg2+ such as atomic fluorescence spectrometry (AFS) [3,4] and inductively coupled plasma mass spectrometry (ICP-MS) [5] require very expensive, complex, and bulky instruments.”
BackgroundSelf-citationDetection methods for centrifugal microfluidic platforms
Burger, R., Amato, L., & Boisen, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.075 · Cited by 76
Li, Z., Xia, S., Wang, J., Bian, C., & Tong, J. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.08.061 · Cited by 63
Self-citationZhang, R., Peng, M., Zheng, C., Xu, K., & Hou, X. (2016) · Microchemical Journal · doi:10.1016/j.microc.2016.02.006 · Cited by 63
Morelli, L., Serioli, L., Centorbi, F. A., Jendresen, C. B., Matteucci, M., Ilchenko, O. O., Demarchi, D., Nielsen, A. T., Zór, K., & Boisen, A. (2018) · Lab on a Chip · doi:10.1039/c7lc01217a · Cited by 49 · cited 1×
“performed LLE on a centrifugal microfluidic device with extraction efficiency matching that of conventional batch extraction [20].”
Automated Liquid–Liquid Extraction by Pneumatic Recirculation on a Centrifugal Microfluidic Platform
Kazarine, A., Kong, M. C. R., Templeton, E. J., & Salin, E. D. (2012) · Analytical Chemistry · doi:10.1021/ac301421k · Cited by 34 · cited 1×
“utilized pneumatic pumping for a multi-cycle LLE process on a centrifugal microfluidic device [19].”
Vázquez, M., Brabazon, D., Shang, F., Omamogho, J. O., Glennon, J. D., & Paull, B. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.07.007 · Cited by 28 · cited 1×
“Hence, there is strong motivation to implement sample pretreatment on centrifugal microfluidic devices, also known as “Lab-on-a-disc” [18].”
Hui, Y., Xiong, C., Bian, C., Gui, S., Tong, J., Li, Y., Gao, C., Huang, Y., Tang, W. C., & Xia, S. (2019) · Analytical Methods · doi:10.1039/c9ay00029a · Cited by 27 · cited 4×
“In comparison to IL-DLLME in conventional approaches [12], the volume of the sample was reduced by two orders of magnitude and operation time was reduced to 20 min.”
InfluentialSelf-citationA rapid prototyping technique for valves and filters in centrifugal microfluidic devices
LaCroix-Fralish, A., Templeton, E. J., Salin, E. D., & Skinner, C. D. (2009) · Lab on a Chip · doi:10.1039/b908683h · Cited by 26
Salt-induced ionic liquid dispersive liquid–liquid microextraction and filter separation
Li, Z., Xia, S., Bian, C., & Tong, J. (2015) · Analytical Methods · doi:10.1039/c5ay02554k · Cited by 16 · cited 2×
“This result was consistent with our previous investigation on the impact of NaClO4 on the solubility of IL in water [21].”
Self-citationPi, H., Tong, J., Bian, C., & Xia, S. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa6151 · Cited by 11 · cited 1×
“Microfluidic devices offer attractive alternatives for sample separation, detection, and analysis because of their inherent cost-effective fabrication process, requiring small sample size due to miniaturization, and amenable to automation by integrating multiple functions on the same platform [13,14].”
Self-citationFully Integrated Molecular Diagnostic CD Platform Based on Thermal Control
Kong, L. X. (2015) · eScholarship (California Digital Library) · Cited by 2
Cited by
Herce-Sesa, B., López-López, J. A., & Moreno, C. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116398 · Cited by 86
Recent advances in centrifugal microfluidic chip-based loop-mediated isothermal amplification
Xiao, B., Zhao, R., Wang, N., Zhang, J., Sun, X., & Chen, A. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116836 · Cited by 64
Alidoust, M., Baharfar, M., Manouchehri, M., Yamini, Y., Tajik, M., & Seidi, S. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116352 · Cited by 62
Esmaeili, N., Rakhtshah, J., Kolvari, E., & Shirkhanloo, H. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104632 · Cited by 54
Green micro total analysis systems (GμTAS) for environmental samples
Keçili, R., & Hussain, C. M. (2021) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2021.e00128 · Cited by 33
Metadata
- Authors
- Hui, Y., Liu, Y., Tang, W. C., Song, D., Madou, M., Xia, S., & Wu, T.
- Affiliations
- Chinese Academy of Sciences (CN)
- University of California, Irvine (US)
- Corresponding author
- Wu, Tianzhun
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2019-08-08
- Volume
- 10
- Issue
- 8
- Pages
- 523
- ISSN
- 2072-666X (ISSN-L)
- PMC
- PMC6723164
- OpenAlex
- W2968175262
- Semantic Scholar
- b70c7bc3a5f3eee6b0c44d816b5db26a57cd1475
- Cited by
- 15
- References
- 24
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 2
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Micromachines (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- Major State Basic Research Development Program of China (No. 2015CB352100)
- China Scholarship Council (No. 201704910667)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- mercury(II) detection, ionic liquids, dispersive liquid-liquid microextraction, preconcentration, water analysis, fluorescent probes, capillary valves, phase separation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.