A Review on Mixing in Microfluidics
Open accessAbstract
Small-scale mixing is of uttermost importance in bio- and chemical analyses using micro TAS (total analysis systems) or lab-on-chips. Many microfluidic applications involve chemical reactions where, most often, the fluid diffusivity is very low so that without the help of chaotic advection the reaction time can be extremely long. In this article, we will review various kinds of mixers developed for use in microfluidic devices. Our review starts by defining the terminology necessary to understand the fundamental concept of mixing and by introducing quantities for evaluating the mixing performance, such as mixing index and residence time. In particular, we will review the concept of chaotic advection and the mathematical terms, Poincare section and Lyapunov exponent. Since these concepts are developed from nonlinear dynamical systems, they should play important roles in devising microfluidic devices with enhanced mixing performance. Following, we review the various designs of mixers that are employed in applications. We will classify the designs in terms of the driving forces, including mechanical, electrical and magnetic forces, used to control fluid flow upon mixing. The advantages and disadvantages of each design will also be addressed. Finally, we will briefly touch on the expected future development regarding mixer design and related issues for the further enhancement of mixing performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Aref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Performance comparison of micromixers
Falk, L., & Commenge, J.-M. (2010) · Chemical Engineering Science · doi:10.1016/j.ces.2009.05.045 · Cited by 364
Chaotic micromixers using two-layer crossing channels to exhibit fast mixing at low Reynolds numbers
Xia, H. M., Wan, S. Y. M., Shu, C., & Chew, Y. T. (2005) · Lab on a Chip · doi:10.1039/b502031j · Cited by 243
Current methods for characterising mixing and flow in microchannels
Aubin, J., Ferrando, M., & Jiricny, V. (2010) · Chemical Engineering Science · doi:10.1016/j.ces.2009.12.001 · Cited by 196
Mixing Crowded Biological Solutions in Milliseconds
Liau, A., Karnik, R., Majumdar, A., et al. (2005) · Analytical Chemistry · doi:10.1021/ac050827h · Cited by 129
Effective mixing in a microfluidic chip using magnetic particles
Lee, S. H., van Noort, D., Lee, J. Y., Zhang, B., & Park, T. H. (2008) · Lab on a Chip · doi:10.1039/b814371d · Cited by 119
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Natural polymers for the microencapsulation of cells
Gasperini, L., Mano, J. F., & Reis, R. L. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0817 · Cited by 602
Passive mixers in microfluidic systems: A review
Lee, C.-Y., Wang, W.-T., Liu, C.-C., & Fu, L.-M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.122 · Cited by 550
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
PDMS lab-on-a-chip fabrication using 3D printed templates
Comina, G., Suska, A., & Filippini, D. (2014) · Lab Chip · doi:10.1039/c3lc50956g · Cited by 278
Metadata
- Authors
- Suh, Y. K., & Kang, S.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2010-09-30
- Volume
- 1
- Issue
- 3
- Pages
- 82-111
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W2017460995
- Cited by
- 336
- References
- 21
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review on Mixing in Microfluidics. https://app.cochat.ai/papers/10.3390/mi1030082
- The paper
- Suh, Y. K., & Kang, S. (2010). A Review on Mixing in Microfluidics. Micromachines. https://doi.org/10.3390/mi1030082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.