A Review of Passive Micromixers with a Comparative Analysis
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
A wide range of existing passive micromixers are reviewed, and quantitative analyses of ten typical passive micromixers were performed to compare their mixing indices, pressure drops, and mixing costs under the same axial length and flow conditions across a wide Reynolds number range of 0.01–120. The tested micromixers were selected from five types of micromixer designs. The analyses of flow and mixing were performed using continuity, Navier-Stokes and convection-diffusion equations. The results of the comparative analysis were presented for three different Reynolds number ranges: low-Re (Re ≤ 1), intermediate-Re (1 < Re ≤ 40), and high-Re (Re > 40) ranges, where the mixing mechanisms are different. The results show a two-dimensional micromixer of Tesla structure is recommended in the intermediate- and high-Re ranges, while two three-dimensional micromixers with two layers are recommended in the low-Re range due to their excellent mixing performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 3×
“…microchannel geometries: two-dimensional (2D) structures [30–41], three-dimensional (3D) serpentine structures [42–49], patterned groove structures [29,50–58], 2D and 3D split-and-recombination (SAR) structures [ Several review articles have introduced a variety of passive micromixers with their…”
BackgroundAref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858 · cited 1×
“Chaotic flows induced by repeated perturbations of the fluid flow can significantly increase the performance of micromixers [27–29], and are generated by several di ff erent microchannel geometries: two-dimensional (2D) structures [30–41], three-dimensional (3D) serpentine structures [42–49], patterned…”
BackgroundNguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479 · cited 2×
“The SAR micromixers generate multi-laminating flow patterns successively with the three underlying flow mechanisms of splitting, recombination, and rearrangement [6].”
BackgroundPassive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197 · cited 2×
“Several micromixers involving 3D serpentine and / or SAR structures [42–49, 59– 67 , Ansari and Kim [45] investigated the e ff ects of flow and geometric parameters on the mixing performance of an L-shaped 3D serpentine micromixer (M-5) shown in Figure 5.”
BackgroundPassive mixers in microfluidic systems: A review
Lee, C.-Y., Wang, W.-T., Liu, C.-C., & Fu, L.-M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.122 · Cited by 550
Cai, G., Xue, L., Zhang, H., & Lin, J. (2017) · Micromachines · doi:10.3390/mi8090274 · Cited by 467
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
A novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429
A millisecond micromixer via single-bubble-based acoustic streaming
Ahmed, D., Mao, X., Shi, J., Juluri, B. K., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b903687c · Cited by 415
Performance comparison of micromixers
Falk, L., & Commenge, J.-M. (2010) · Chemical Engineering Science · doi:10.1016/j.ces.2009.05.045 · Cited by 364 · cited 1×
“Falk and Commenge performed a comprehensive study of conventional T-type micromixers and micromixers based on the concept of SAR or multi-lamination through the Villermaux-Dushman test reaction [96].”
Recent advances and applications of micromixers
Lee, C., & Fu, L. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.12.034 · Cited by 293 · cited 1×
“…patterned groove structures [29,50–58], 2D and 3D split-and-recombination (SAR) structures [ Several review articles have introduced a variety of passive micromixers with their mixing mechanisms [6,24,90–95]; these micromixers have various dimensions and working conditions (e.g., Reynolds number).”
BackgroundMicrofluidic technologies in clinical diagnostics
Schulte, T. H., Bardell, R. L., & Weigl, B. H. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00093-1 · Cited by 245
Hybridization Enhancement Using Cavitation Microstreaming
Liu, R. H., Lenigk, R., Druyor-Sanchez, R. L., Yang, J., & Grodzinski, P. (2003) · Analytical Chemistry · doi:10.1021/ac026267t · Cited by 244
Chaotic micromixers using two-layer crossing channels to exhibit fast mixing at low Reynolds numbers
Xia, H. M., Wan, S. Y. M., Shu, C., & Chew, Y. T. (2005) · Lab on a Chip · doi:10.1039/b502031j · Cited by 243 · cited 7×
“This result is in line with the observation in previous studies [84,87] that the saddle‐shaped flow structure enhances mixing by stretching and folding of the fluid interfaces.”
BackgroundMethodResultInfluentialOptimizing layout of obstacles for enhanced mixing in microchannels
Wang, H., Iovenitti, P., Harvey, E., & Masood, S. (2002) · Smart Materials and Structures · doi:10.1088/0964-1726/11/5/306 · Cited by 238 · cited 2×
“Mechanical stirri g is not an effective method for enhancing mixing [36] because the secondary flow is hardly induced in this range.”
MethodA barrier embedded chaotic micromixer
Kim, D. S., Lee, S. W., Kwon, T. H., & Lee, S. S. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/006 · Cited by 236 · cited 7×
“M-8 shows the lowest mixing indices among the 3D micromixers, which are even lower than those of some 2-”
BackgroundInfluentialApplications of micromixing technology
Jeong, G. S., Chung, S., Kim, C.-B., & Lee, S.-H. (2010) · The Analyst · doi:10.1039/b921430e · Cited by 234 · cited 1×
“Such information will assist in the selection of suitable designs to meet specific requirements for different processes [92].”
BackgroundIntegrated microsystems for controlled drug delivery
Zafar Razzacki, S. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.012 · Cited by 224
Micro Total Analysis Systems: Fundamental Advances and Biological Applications
Culbertson, C. T., Mickleburgh, T. G., Stewart-James, S. A., Sellens, K. A., & Pressnall, M. (2014) · Analytical Chemistry · doi:10.1021/ac403688g · Cited by 183 · cited 1×
“Efficient mixing significantly improves the detection sensitivity and reduces the analysis time [16,17].”
BackgroundA high-performance micromixer using three-dimensional Tesla structures for bio-applications
Yang, A.-S., Chuang, F.-C., Chen, C.-K., Lee, M.-H., Chen, S.-W., Su, T.-L., & Yang, Y.-C. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.11.034 · Cited by 180 · cited 1×
“For example, fast mixing of cells, reagents, and organic solutions are essential in many bioengineering and biochemical systems [11–13].”
BackgroundThree-dimensionally crossing manifold micro-mixer for fast mixing in a short channel length
Lim, T. W., Son, Y., Jeong, Y. J., Yang, D., Kong, H. J., Lee, K.-S., & Kim, D. (2011) · Lab on a Chip · doi:10.1039/c005325m · Cited by 167
Park, T., Lee, S., Seong, G. H., Choo, J., Lee, E. K., Kim, Y. S., Ji, W. H., Hwang, S. Y., Gweon, D., & Lee, S. (2005) · Lab on a Chip · doi:10.1039/b414457k · Cited by 163
Biosensors with label-free detection designed for diagnostic applications
Rapp, B. E., Gruhl, F. J., & Länge, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3906-2 · Cited by 150
Investigation of micromixing by acoustically oscillated sharp-edges
Nama, N., Huang, P., Huang, T. J., & Costanzo, F. (2016) · Biomicrofluidics · doi:10.1063/1.4946875 · Cited by 148
Chen, Q., Wu, J., Zhang, Y., & Lin, J.-M. (2012) · Analytical Chemistry · doi:10.1021/ac300003k · Cited by 130
Mélange passif dans les microcanaux : fabrication et expérience
Beebe, D. J. (2001) · Mécanique & Industries · doi:10.1016/s1296-2139(01)01114-9 · Cited by 124 · cited 1×
“The 3D serpentine path induces a stirring flow at each bend and generates a secondary flow to enhance mixing [43,45].”
BackgroundHossain, S., Lee, I., Kim, S. M., & Kim, K.-Y. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.06.106 · Cited by 118 · cited 5×
“This result is in line with the observation in previous studies [84,87] that the saddle‐shaped flow structure enhances mixing by stretching and folding of the fluid interfaces.”
MethodResultInfluentialSelf-citationAdvances in size-exclusion separations of proteins and polymers by UHPLC
Bouvier, E. S. P., & Koza, S. M. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.08.002 · Cited by 114 · cited 1×
“Efficient mixing significantly improves the detection sensitivity and reduces the analysis time [16,17].”
BackgroundAcoustofluidic Synthesis of Particulate Nanomaterials
Huang, P., Zhao, S., Bachman, H., Nama, N., Li, Z., Chen, C., Yang, S., Wu, M., Zhang, S. P., & Huang, T. J. (2019) · Advanced Science · doi:10.1002/advs.201900913 · Cited by 99 · cited 1×
“A notable example of the mixing of reagents or organic solutions is nanomaterial synthesis [14,15].”
BackgroundWang, W.-T., Zhao, S.-F., Shao, T., Jin, Y., & Cheng, Y. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.03.073 · Cited by 79
Feng, X., Ren, Y., & Jiang, H. (2013) · Biomicrofluidics · doi:10.1063/1.4827598 · Cited by 75
Microreactors for Gold Nanoparticles Synthesis: From Faraday to Flow
Rahman, M. H., & Rebrov, E. V. (2014) · Processes · doi:10.3390/pr2020466 · Cited by 74
A sharp-edge-based acoustofluidic chemical signal generator
Huang, P., Chan, C. Y., Li, P., Wang, Y., Nama, N., Bachman, H., & Huang, T. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00193f · Cited by 66 · cited 1×
“Sharp-edge-based acoustic active micromixers [20,21] with serpentine-like channels were recently fabricated in a simple manner and used for versatile applications.”
MethodHuang, P., Chan, C. Y., Li, P., Nama, N., Xie, Y., Wei, C., Chen, Y., Ahmed, D., & Huang, T. J. (2015) · Lab on a Chip · doi:10.1039/c5lc00868a · Cited by 63 · cited 1×
“Sharp-edge-based acoustic active micromixers [20,21] with serpentine-like channels were recently fabricated in a simple manner and used for versatile applications.”
MethodNumerical characterization of simple three-dimensional chaotic micromixers
Lin, Y. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.04.123 · Cited by 63
Improved serpentine laminating micromixer with enhanced local advection
Park, J. M., Kim, D. S., Kang, T. G., & Kwon, T. H. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0208-x · Cited by 60 · cited 10×
“2 2D designs with SAR structures [68–79] Inertial force, SAR M-3 [68], M-4 [77] 3 3D design with serpentine and/or SAR structures [42–49,59–67,80,81] Inertial force, chaotic mixing, multi-lamination M-5 [45], M-6 [59], M-7 [81]”
BackgroundInfluentialIngham, C. J., & Vlieg, J. E. T. V. H. (2008) · Lab on a Chip · doi:10.1039/b804790a · Cited by 59
Westerhausen, C., Schnitzler, L. G., Wendel, D., Krzysztoń, R., Lächelt, U., Wagner, E., Rädler, J. O., & Wixforth, A. (2016) · Micromachines · doi:10.3390/mi7090150 · Cited by 45
Acoustofluidic devices controlled by cell phones
Bachman, H., Huang, P., Zhao, S., Yang, S., Zhang, P., Fu, H., & Huang, T. J. (2018) · Lab on a Chip · doi:10.1039/c7lc01222e · Cited by 35 · cited 1×
“Furthermore, an active acoustic-based micromixer [18] also achieved”
BackgroundRismanian, M., Saidi, M. S., & Kashaninejad, N. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.11.041 · Cited by 33 · cited 1×
“Passive micromixers are also used as ‘concentration gradient generators’ for biological and pharmaceutical applications [25,26].”
Numerical characterization of three‐dimensional serpentine micromixers
Park, J. M., & Kwon, T. H. (2008) · AIChE Journal · doi:10.1002/aic.11537 · Cited by 32 · cited 2×
“…generated by several di ff erent microchannel geometries: two-dimensional (2D) structures [30–41], three-dimensional (3D) serpentine structures [42–49], patterned groove structures [29,50–58], 2D and 3D split-and-recombination (SAR) structures [ Several review articles have introduced a variety…”
BackgroundA tool for designing tree-like concentration gradient generators for lab-on-a-chip applications
Ebadi, M., Moshksayan, K., Kashaninejad, N., Saidi, M. S., & Nguyen, N. (2019) · Chemical Engineering Science · doi:10.1016/j.ces.2019.115339 · Cited by 31 · cited 1×
“Passive micromixers are also used as ‘concentration gradient generators’ for biological and pharmaceutical applications [25,26].”
Three-dimensional staggered herringbone mixer fabricated by femtosecond laser direct writing
Lin, D., He, F., Liao, Y., Lin, J., Liu, C., Song, J., & Cheng, Y. (2013) · Journal of Optics · doi:10.1088/2040-8978/15/2/025601 · Cited by 25
Cited by
A Review of Cyclic Olefin Copolymer Applications in Microfluidics and Microdevices
Agha, A., Waheed, W., Alamoodi, N., Mathew, B., Alnaimat, F., Abu‐Nada, E., Abderrahmane, A., & Alazzam, A. (2022) · Macromolecular Materials and Engineering · doi:10.1002/mame.202200053 · Cited by 173
Metadata
- Authors
- Raza, W., Hossain, S., & Kim, K.-Y.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2020-04-27
- Volume
- 11
- Issue
- 5
- Pages
- 455
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W3017908266
- Cited by
- 182
- References
- 46
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.