Qualitative and Quantitative Analysis of Tumor Cell Metabolism via Stable Isotope Labeling Assisted Microfluidic Chip Electrospray Ionization Mass Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this work, a stable isotope labeling assisted microfluidic chip electrospray ionization mass spectrometry (SIL-chip-ESI-MS) platform for qualitative and quantitative analysis of cell metabolism was developed. Microfluidic cell culture, drug-induced cell apoptosis analysis, and cell metabolism measurements were performed simultaneously on the specifically designed device. MCF-7 cells were cultivated in vitro and exposed in anticancer agent (genistein and genistein-d(2)) for cell-based drug assay. A dual-isotopic labeling was presented for effective qualitative analysis of multiplex metabolites. Interestingly, three coeluting pairs of isotopomers appeared with an m/z difference of two. Despite complex biological matrixes, they can be easily recognized and identified by chip-ESI-MS/MS, which significantly facilitates candidate biomarker discovery. The quantitative performance of this system was evaluated using genistein as a model drug by means of stable isotope dilution analysis. The linear equation obtained is y = 0.06x - 3.38 × 10(-3) (R(2) = 0.995) at the dynamic range from 0.5 to 40 μM. The detection limit is 0.2 μM. The method shows an excellent stability of 2.2% relative standard deviation (RSD) and a good repeatability of 5.5% RSD. Our results have successfully demonstrated the capability of selective and quantitative analysis of cell-based drug absorption and metabolites with high stability, sensitivity, and repeatability on the chip-ESI-MS system. Consequently, the present device shows promise as a high-throughput, low-cost, and online platform for cell metabolism studies and drug screening processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass-spectrometric identification and relative quantification of N-linked cell surface glycoproteins
Wollscheid, B., Bausch-Fluck, D., Henderson, C., O'Brien, R., Bibel, M., Schiess, R., Aebersold, R., & Watts, J. D. (2009) · Nature Biotechnology · doi:10.1038/nbt.1532 · Cited by 547
Cited by
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
“For instance, Chen et al. (2012) developed a microfluidic system combining cell culture with stable isotope labeling-assisted electrospray ionization mass spectrometry.”
MethodAdvances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Gao, D., Liu, H., Lin, J.-M., Wang, Y., & Jiang, Y. (2013) · Lab on a Chip · doi:10.1039/c2lc41215b · Cited by 135
Self-citation
Metadata
- Authors
- Chen, Q., Wu, J., Zhang, Y., & Lin, J.-M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-24
- Volume
- 84
- Issue
- 3
- Pages
- 1695-1701
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2022245975
- Cited by
- 130
- References
- 1
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Qualitative and Quantitative Analysis of Tumor Cell Metabolism via Stable Isotope Labeling Assisted Microfluidic Chip Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac300003k
- The paper
- Chen, Q., Wu, J., Zhang, Y., & Lin, J.-M. (2012). Qualitative and Quantitative Analysis of Tumor Cell Metabolism via Stable Isotope Labeling Assisted Microfluidic Chip Electrospray Ionization Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac300003k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.