The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Label and Label-Free Detection Techniques for Protein Microarrays
Open accessAbstract
Protein microarray technology has gone through numerous innovative developments in recent decades. In this review, we focus on the development of protein detection methods embedded in the technology. Early microarrays utilized useful chromophores and versatile biochemical techniques dominated by high-throughput illumination. Recently, the realization of label-free techniques has been greatly advanced by the combination of knowledge in material sciences, computational design and nanofabrication. These rapidly advancing techniques aim to provide data without the intervention of label molecules. Here, we present a brief overview of this remarkable innovation from the perspectives of label and label-free techniques in transducing nano‑biological events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Global Analysis of Protein Activities Using Proteome Chips
Zhu, H., Bilgin, M., Bangham, R., Hall, D., Casamayor, A., Bertone, P., Lan, N., Jansen, R., Bidlingmaier, S., Houfek, T., et al. (2001) · Science · doi:10.1126/science.1062191 · Cited by 1,884
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Cited by
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Graphene-Based Materials for Biosensors: A Review
Suvarnaphaet, P., & Pechprasarn, S. (2017) · Sensors · doi:10.3390/s17102161 · Cited by 490
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Philip, A., & Kumar, A. R. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214424 · Cited by 281
Chakraborty, A., & Sarkar, A. (2017) · Journal of Computational Electronics · doi:10.1007/s10825-017-0999-2 · Cited by 94
Metadata
- Authors
- Syahir, A., Usui, K., Tomizaki, K.-Y., Kajikawa, K., & Mihara, H.
- Venue
- Microarrays
- Publisher
- MDPI AG
- Published
- 2015-04-24
- Volume
- 4
- Issue
- 2
- Pages
- 228-244
- ISSN
- 2076-3905 (ISSN-L)
- OpenAlex
- W1983962835
- Cited by
- 194
- References
- 3
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label and Label-Free Detection Techniques for Protein Microarrays. https://app.cochat.ai/papers/10.3390/microarrays4020228
- The paper
- Syahir, A., Usui, K., Tomizaki, K.-Y., Kajikawa, K., & Mihara, H. (2015). Label and Label-Free Detection Techniques for Protein Microarrays. Microarrays. https://doi.org/10.3390/microarrays4020228
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.