The DOI matches its Crossref record; 266 of the 266 references it cites were found in a registry or an index.
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Open accessAbstract
Fluorescence microscopy provides an efficient and unique approach to study fixed and living cells because of its versatility, specificity, and high sensitivity. Fluorescence microscopes can both detect the fluorescence emitted from labeled molecules in biological samples as images or photometric data from which intensities and emission spectra can be deduced. By exploiting the characteristics of fluorescence, various techniques have been developed that enable the visualization and analysis of complex dynamic events in cells, organelles, and sub-organelle components within the biological specimen. The techniques described here are fluorescence recovery after photobleaching (FRAP), the related fluorescence loss in photobleaching (FLIP), fluorescence localization after photobleaching (FLAP), Förster or fluorescence resonance energy transfer (FRET) and the different ways how to measure FRET, such as acceptor bleaching, sensitized emission, polarization anisotropy, and fluorescence lifetime imaging microscopy (FLIM). First, a brief introduction into the mechanisms underlying fluorescence as a physical phenomenon and fluorescence, confocal, and multiphoton microscopy is given. Subsequently, these advanced microscopy techniques are introduced in more detail, with a description of how these techniques are performed, what needs to be considered, and what practical advantages they can bring to cell biological research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–266 of 266
Vosch, T., Cotlet, M., Hofkens, J., Biest, K. V. D., Lor, M., Weston, K. D., Tinnefeld, P., Sauer, M., Latterini, L., Müllen, K., et al. (2003) · The Journal of Physical Chemistry A · doi:10.1021/jp034906d · Cited by 115
Callis, P. R., & Vivian, J. T. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(02)02046-8 · Cited by 114
Larson, D. R., Ma, Y. M., Vogt, V. M., & Webb, W. W. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200303200 · Cited by 113
Riven, I., Kalmanzon, E., Segev, L., & Reuveny, E. (2003) · Neuron · doi:10.1016/s0896-6273(03)00193-4 · Cited by 112
Principles of Multiphoton Microscopy
Dunn, K. W., & Young, P. A. (2006) · Nephron Experimental Nephrology · doi:10.1159/000090614 · Cited by 111
Small photoactivatable molecules for controlled fluorescence activation in living cells
Puliti, D., Warther, D., Orange, C., Specht, A., & Goeldner, M. P. (2010) · Bioorganic & Medicinal Chemistry · doi:10.1016/j.bmc.2010.07.011 · Cited by 111
VII.—On the Estimation of Aperture in the Microscope.
Abbe, E. (1881) · Journal of the Royal Microscopical Society · doi:10.1111/j.1365-2818.1881.tb05909.x · Cited by 107
Recent Progress in Strategies for the Creation of Protein‐Based Fluorescent Biosensors
Wang, H.-X., Nakata, E., & Hamachi, I. (2009) · ChemBioChem · doi:10.1002/cbic.200900249 · Cited by 105
Use of caged fluorochromes to track macromolecular movement in living cells
Politz, J. C. R. (1999) · Trends in Cell Biology · doi:10.1016/s0962-8924(99)01585-8 · Cited by 103
Monitoring multiple distances within a single molecule using switchable FRET
Uphoff, S., Holden, S. J., Reste, L. L., Periz, J., van de Linde, S., Heilemann, M., & Kapanidis, A. N. (2010) · Nature Methods · doi:10.1038/nmeth.1502 · Cited by 102
Gu, Y., Di, W., Kelsell, D. P., & Zicha, D. (2004) · Journal of Microscopy · doi:10.1111/j.0022-2720.2004.01365.x · Cited by 101
Optical Lock-In Detection of FRET Using Synthetic and Genetically Encoded Optical Switches
Mao, S., Benninger, R. K. P., Yan, Y., et al. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.124859 · Cited by 100
Quantum Dots—From Synthesis to Applications in Biomedicine and Life Sciences
Drummen, G. P. C. (2010) · International Journal of Molecular Sciences · doi:10.3390/ijms11010154 · Cited by 97
Self-citationSurfing on a new wave of single-molecule fluorescence methods
Hohlbein, J., Gryte, K., Heilemann, M., & Kapanidis, A. N. (2010) · Physical Biology · doi:10.1088/1478-3975/7/3/031001 · Cited by 97
Shyu, Y. J., Hiatt, S. M., Duren, H. M., Ellis, R. E., Kerppola, T. K., & Hu, C. (2008) · Nature Protocols · doi:10.1038/nprot.2008.16 · Cited by 96
Quantification of integrin receptor agonism by fluorescence lifetime imaging
Parsons, M., Messent, A., Humphries, J. D., Deakin, N. O., & Humphries, M. J. (2008) · Journal of Cell Science · doi:10.1242/jcs.018440 · Cited by 96
GFP: Lighting Up Life (Nobel Lecture)
Chalfie, M. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902040 · Cited by 96
FRET in Cell Biology: Still Shining in the Age of Super‐Resolution?
Grecco, H. E., & Verveer, P. J. (2010) · ChemPhysChem · doi:10.1002/cphc.201000795 · Cited by 93
Llères, D., Swift, S., & Lamond, A. I. (2007) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy1210s42 · Cited by 92
Mechanical Strain in Actin Networks Regulates FilGAP and Integrin Binding to Filamin A
Ehrlicher, A. J., Nakamura, F., Hartwig, J. H., Weitz, D. A., & Stossel, T. P. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.1905 · Cited by 92
Stable expression of FRET biosensors: A new light in cancer research
Aoki, K., Komatsu, N., Hirata, E., Kamioka, Y., & Matsuda, M. (2011) · Cancer Science · doi:10.1111/j.1349-7006.2011.02196.x · Cited by 90
Jovin, T. M., & Vaz, W. L. C. (1989) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(89)72030-9 · Cited by 90
Upconversion Fluorescence Enables Homogeneous Immunoassay in Whole Blood
Kuningas, K., Päkkilä, H., Ukonaho, T., Rantanen, T., Lövgren, T. N.-E., & Soukka, T. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.076687 · Cited by 89
Fluorescence Recovery after Photobleaching: Application to Nuclear Proteins
Houtsmuller, A. B. (2005) · Advances in biochemical engineering, biotechnology · doi:10.1007/b102214 · Cited by 88
Dissecting the binding mechanism of the linker histone in live cells: an integrated FRAP analysis
Stasevich, T. J., Mueller, F., Brown, D. T., & McNally, J. G. (2010) · The EMBO Journal · doi:10.1038/emboj.2010.24 · Cited by 87
Reversible Dimerization of EGFR Revealed by Single‐Molecule Fluorescence Imaging Using Quantum Dots
Kawashima, N., Nakayama, K., Itoh, K., Itoh, T., Ishikawa, M., & Biju, V. (2009) · Chemistry - A European Journal · doi:10.1002/chem.200902963 · Cited by 86
Polarized Fluorescence Resonance Energy Transfer Microscopy
Mattheyses, A. L., Hoppe, A. D., & Axelrod, D. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.036194 · Cited by 86
Visualization of Molecular Activities Inside Living Cells with Fluorescent Labels
Bunt, G., & Wouters, F. S. (2004) · International review of cytology · doi:10.1016/s0074-7696(04)37005-1 · Cited by 85
Nucleocytoplasmic shuttling revealed by FRAP and FLIP technologies
Köster, M., Frahm, T., & Häuser, H. (2004) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.11.002 · Cited by 74
Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues
Durr, N. J., Ben‐Yakar, A., Weisspfennig, C. T., & Holfeld, B. A. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3548646 · Cited by 74
Reymann, J., Baddeley, D., Gunkel, M., Lemmer, P., Stadter, W., Jegou, T., Rippe, K., Cremer, C. G., & Birk, U. J. (2008) · Chromosome Research · doi:10.1007/s10577-008-1238-2 · Cited by 72
Dunn, G., Dobbie, I. M., Monypenny, J., Holt, M., & Zicha, D. (2002) · Journal of Microscopy · doi:10.1046/j.0022-2720.2001.001007.x · Cited by 67
Simultaneous DNA Binding and Bending by EcoRV Endonuclease Observed by Real-Time Fluorescence
Hiller, D. A., Fogg, J. M., Martin, A. M., Beechem, J., Reich, N. O., & Perona, J. J. (2003) · Biochemistry · doi:10.1021/bi035520w · Cited by 66
Spatiotemporal dynamics of the COPI vesicle machinery
Elsner, M., Hashimoto, H., Simpson, J. C., Cassel, D., Nilsson, T., & Weiß, M. (2003) · EMBO Reports · doi:10.1038/sj.embor.embor942 · Cited by 64
FRET for lab-on-a-chip devices — current trends and future prospects
Varghese, S. S., Zhu, Y., Davis, T. J., & Trowell, S. (2010) · Lab on a Chip · doi:10.1039/b924271f · Cited by 63
Multi-photon excitation imaging of dynamic processes in living cells and tissues
Benninger, R. K. P., Hao, M., & Piston, D. W. (2008) · Springer eBooks · doi:10.1007/112_2008_801 · Cited by 61
A Molecular Ruler for Measuring Quantitative Distance Distributions
Mathew-Fenn, R. S., Das, R., Silverman, J., et al. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003229 · Cited by 61
Direct Observation of Collective Blinking and Energy Transfer in a Bichromophoric System
Tinnefeld, P., Buschmann, V., Weston, K. D., & Sauer, M. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp026565u · Cited by 61
Imaging of protein cluster sizes by means of confocal time-gated fluorescence anisotropy microscopy
Bader, A. N., Hofman, E. G., Henegouwen, P. M. P. V. B. E., et al. (2007) · Optics Express · doi:10.1364/oe.15.006934 · Cited by 59
Microscope Phase Fluorometer for Determining the Fluorescence Lifetimes of Fluorochromes
Venetta, B. D. (1959) · Review of Scientific Instruments · doi:10.1063/1.1716652 · Cited by 57
Rajaram, N., & Kerppola, T. K. (2004) · Molecular and Cellular Biology · doi:10.1128/mcb.24.13.5694-5709.2004 · Cited by 56
Introduction to Confocal Microscopy
Wright, S. J., & Wright, D. J. (2002) · Methods in cell biology · doi:10.1016/s0091-679x(02)70002-2 · Cited by 56
Nuclear proteins: finding and binding target sites in chromatin
van Royen, M. E., Zotter, A., Ibrahim, S., Geverts, B., & Houtsmuller, A. B. (2010) · Chromosome Research · doi:10.1007/s10577-010-9172-5 · Cited by 52
Photophysics of Clomeleon by FLIM: Discriminating Excited State Reactions along Neuronal Development
Jose, M., Nair, D. K., Reißner, C., Hartig, R., & Zuschratter, W. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.092841 · Cited by 51
Zhang, X., Tee, Y. H., Heng, J. K., Zhu, Y., Hu, X., Margadant, F., Ballestrem, C., Bershadsky, A. D., Griffiths, G., & Yu, H. (2010) · Journal of Cell Science · doi:10.1242/jcs.069153 · Cited by 51
Mills, J. D., Stone, J. R., Rubin, D. G., et al. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1584443 · Cited by 51
Giese, B., Au-Yeung, C.-K., Herrmann, A., Diefenbach, S., Haan, C., Küster, A., Wortmann, S. B., Roderburg, C., Heinrich, P. C., Behrmann, I., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m303347200 · Cited by 49
Optical methods for exploring dynamics of single copies of green fluorescent protein
Moerner, W. E., Peterman, E. J. G., Brasselet, S., Kummer, S., & Dickson, R. M. (1999) · Cytometry · Cited by 48
Issues in confocal microscopy for quantitative FRET analysis
Wallrabe, H. K., Chen, Y., Periasamy, A., & Barroso, M. (2006) · Microscopy Research and Technique · doi:10.1002/jemt.20281 · Cited by 47
The Kindling Fluorescent Protein: A Transient Photoswitchable Marker
Henderson, J. N., & Remington, S. J. (2006) · Physiology · doi:10.1152/physiol.00056.2005 · Cited by 46
Elder, A. D., Matthews, S. M., Swartling, J., Yunus, K., Frank, J. H., Brennan, C. M., Fisher, A. C., & Kaminski, C. F. (2006) · Optics Express · doi:10.1364/oe.14.005456 · Cited by 43
Nonmuscle Myosin II helps regulate synaptic vesicle mobility at the Drosophilaneuromuscular junction
Seabrooke, S., Qiu, X., & Stewart, B. A. (2010) · BMC Neuroscience · doi:10.1186/1471-2202-11-37 · Cited by 41
The physics and biology of fluorescence microscopy in the life sciences
Wouters, F. S. (2006) · Contemporary Physics · doi:10.1080/00107510601089832 · Cited by 40
Human Myosin III Is a Motor Having an Extremely High Affinity for Actin
Kambara, T., Komaba, S., & Ikebe, M. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m603823200 · Cited by 37
Imaging Protein‐Protein Interactions by Fluorescence Resonance Energy Transfer (FRET) Microscopy
Wouters, F. S., & Bastiaens, P. I. H. (2001) · Current Protocols in Protein Science · doi:10.1002/0471140864.ps1905s23 · Cited by 33
Intrinsically Resolution Enhancing Probes for Confocal Microscopy
Vogelsang, J., Cordes, T., Forthmann, C., Steinhauer, C., & Tinnefeld, P. (2010) · Nano Letters · doi:10.1021/nl903823s · Cited by 26
Quantitative linear unmixing of CFP and YFP from spectral images acquired with two‐photon excitation
Thaler, C., & Vogel, S. S. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20267 · Cited by 25
Methods for Expressing and Analyzing GFP-Tubulin and GFP-Microtubule-Associated ProteinsPreprint
Goodson, H. V., Dzurisin, J. S., & Wadsworth, P. (2010) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top85 · Cited by 25
FRAP and FRET Methods to Study Nuclear Receptors in Living Cells
van Royen, M. E., Dinant, C., Farla, P., Trapman, J., & Houtsmuller, A. B. (2009) · Methods in molecular biology · doi:10.1007/978-1-60327-575-0_5 · Cited by 25
Fluorescence-based methods to image palmitoylated proteins
Kenworthy, A. K. (2006) · Methods · doi:10.1016/j.ymeth.2006.06.021 · Cited by 24
Live cell imaging of the cancer‐related transcription factor RUNX2 during mitotic progression
Pockwinse, S. M., Kota, K. P., Quaresma, A. J. C., Imbalzano, A. N., Lian, J. B., van Wijnen, A. J., Stein, J. L., Stein, G. S., & Nickerson, J. A. (2010) · Journal of Cellular Physiology · doi:10.1002/jcp.22465 · Cited by 21
Modeling capping protein FRAP and CALI experiments reveals in vivo regulation of actin dynamics
Kapustina, M., Vitriol, E. A., Elston, T. C., Loew, L. M., & Jacobson, K. (2010) · Cytoskeleton · doi:10.1002/cm.20463 · Cited by 19
Measuring Histone and Polymerase Dynamics in Living Cells
Kimurâ, H., Hieda, M., & Cook, P. R. (2003) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(03)75024-1 · Cited by 18
Kinoshita, K., Goryo, K., Takada, M., Tomokuni, Y., Aso, T., Okuda, H., Shuin, T., Fukumura, H., & Sogawa, K. (2007) · FEBS Journal · doi:10.1111/j.1742-4658.2007.06075.x · Cited by 9
Fluorescence Localization After Photobleaching ( FLAP )
Dunn, G., Holt, M., Soong, D. Y. H., Gray, C., & Zicha, D. (2004) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb2102s24 · Cited by 6
Research works printed but not linked: 43
- 1911, The fluorescence microscope (Das Fluoreszenzmikroskop), Z Wiss Mikrosk, 28, 330
- Solon, 1961, Physiological implications of laser beams, Science, 134, 1506, 10.1126/science.134.3489.1506 · doi:10.1126/science.134.3489.1506
- Shimomura, 2009, Discovery of green fluorescent protein (GFP) (Nobel Lecture), Angew. Chem. Int. Ed. Engl., 48, 5590, 10.1002/anie.200902240 · doi:10.1002/anie.200902240
- Mitchell, 2008, Selective detection of luminescence from semiconductor quantum dots by nanosecond time-gated imaging with a colour-masked CCD detector, J. Microsc., 230, 172, 10.1111/j.1365-2818.2008.01973.x · doi:10.1111/j.1365-2818.2008.01973.x
- Swift, 2004, Basic principles of FRAP, FLIM and FRET, Proc. Royal Mic. Soc., 39, 3
- Taylor, 1989, Basic fluorescence microscopy, Methods Cell Biol., 29, 207, 10.1016/S0091-679X(08)60196-X · doi:10.1016/s0091-679x(08)60196-x
- Airy, 1835, On the diffraction of an object-glass with circular aperture, Trans. Cambridge Phil. Soc., 5, 283
- Diaspro, A. (2002). Handbook of Biological Confocal Microscopy, Wiley-Liss.
- Paddock, 2000, Principles and practices of laser scanning confocal microscopy, Mol. Biotechnol., 16, 127, 10.1385/MB:16:2:127 · doi:10.1385/mb:16:2:127
- Yersin, 2001, Upconversion processes in transition metal and rare earth metal systems, Transition Metal and Rare Earth Compounds: Topics in Current Chemistry, 214, 1, 10.1007/3-540-44474-2_1 · doi:10.1007/3-540-44474-2_1
- Auzel, F.E. (2002). Up-Conversion in Rare-Earth-Doped Systems: Past, Present and Future, SPIE. · doi:10.1117/12.475333
- Soukka, 2008, Photon upconversion in homogeneous fluorescence-based bioanalytical assays, Ann. NY Acad. Sci., 1130, 188, 10.1196/annals.1430.027 · doi:10.1196/annals.1430.027
- Tocanne, 1989, Lipid lateral diffusion and membrane organization, FEBS Lett., 257, 10, 10.1016/0014-5793(89)81774-0 · doi:10.1016/0014-5793(89)81774-0
- Smith, 2003, Microtubule-dependent transport of secretory vesicles in RBL-2H3 cells, Traffic, 4, 302, 10.1034/j.1600-0854.2003.00084.x · DOI
- Tripathi, 2008, Differential dynamics of splicing factor SC35 during the cell cycle, J. Biosci., 33, 345, 10.1007/s12038-008-0054-3 · doi:10.1007/s12038-008-0054-3
- Hitakomate, 2010, The methylated N-terminal tail of RCC1 is required for stabilisation of its interaction with chromatin by Ran in live cells, BMC Cell Biol., 11, 43, 10.1186/1471-2121-11-43 · doi:10.1186/1471-2121-11-43
- Kota, 2008, Binding of ATP to UAP56 is necessary for mRNA export, J. Cell Sci., 121, 1526, 10.1242/jcs.021055 · doi:10.1242/jcs.021055
- Balse, 2009, Cholesterol modulates the recruitment of Kv1.5 channels from Rab11-associated recycling endosome in native atrial myocytes, Proc. Natl. Acad. Sci. USA, 106, 14681, 10.1073/pnas.0902809106 · doi:10.1073/pnas.0902809106
- Rotblat, 2010, H-Ras nanocluster stability regulates the magnitude of MAPK signal output, PLoS One, 5, e11991, 10.1371/journal.pone.0011991 · doi:10.1371/journal.pone.0011991
- Klonis, 2002, Fluorescence photobleaching analysis for the study of cellular dynamics, Eur. Biophys. J., 31, 36, 10.1007/s00249-001-0202-2 · doi:10.1007/s00249-001-0202-2
- Ishihama, 2008, The dynamics of pre-mRNAs and poly(A)+ RNA at speckles in living cells revealed by iFRAP studies, Exp. Cell Res., 314, 748, 10.1016/j.yexcr.2007.10.023 · doi:10.1016/j.yexcr.2007.10.023
- Lundin, 2001, Development of a time-resolved fluorescence resonance energy transfer assay (cell TR-FRET) for protein detection on intact cells, Anal. Biochem., 299, 92, 10.1006/abio.2001.5370 · doi:10.1006/abio.2001.5370
- Koushik, 2009, Anomalous surplus energy transfer observed with multiple FRET acceptors, PLoS One, 4, e8031, 10.1371/journal.pone.0008031 · doi:10.1371/journal.pone.0008031
- Sun, 2010, Three-color spectral FRET microscopy localizes three interacting proteins in living cells, Biophys. J., 99, 1274, 10.1016/j.bpj.2010.06.004 · doi:10.1016/j.bpj.2010.06.004
- Liu, 2011, Biosensors of DsRed as FRET partner with CFP or GFP for quantitatively imaging induced activation of Rac, Cdc42 in living cells, Mol. Imaging. Biol., 13, 424, 10.1007/s11307-010-0381-2 · doi:10.1007/s11307-010-0381-2
- Shchyolkina, 2004, Formation of an intramolecular triple-stranded DNA structure monitored by fluorescence of 2-aminopurine or 6-methylisoxanthopterin, Nucleic Acids Res., 32, 432, 10.1093/nar/gkh158 · doi:10.1093/nar/gkh158
- Youvan, 1997, Calibration of fuorescence resonance energy transfer in microscopy using genetically engineered GFP derivatives on nickel chelating beads, Biotechnology et alia, 3, 1
- Wang, 1989, A fluorescence lifetime distribution measurement system based on phase-resolved detection using an image sissector tube, Appl. Spectrosc., 43, 840, 10.1366/0003702894202364 · doi:10.1366/0003702894202364
- Gadella, 2004, Suppression of photobleaching-induced artifacts in frequency-domain FLIM by permutation of the recording order, Cytometry A, 58, 185
- Periasamy, A., and So, P. (2003). High resolution TCSPC lifetime imaging, Multiphoton Microscopy in the Biomedical Sciences III, 2003, BIOS, Proceedings of SPIE.
- Seah, 2006, Application of fluorescence lifetime imaging (FLIM) in latent finger mark detection, Forensic. Sci. Int., 160, 109, 10.1016/j.forsciint.2005.08.018 · doi:10.1016/j.forsciint.2005.08.018
- Robinson, 2008, Three-dimensional molecular mapping in a microfluidic mixing device using fluorescence lifetime imaging, Opt. Lett., 33, 1887, 10.1364/OL.33.001887 · doi:10.1364/ol.33.001887
- Wouters, 2008, Quantitative analysis of fluorescence lifetime imaging made easy, HFSP J., 2, 7, 10.2976/1.2833600 · doi:10.2976/1.2833600
- Fereidouni, 2011, A modified phasor approach for analyzing time-gated fluorescence lifetime images, J. Microsc., 244, 248, 10.1111/j.1365-2818.2011.03533.x · doi:10.1111/j.1365-2818.2011.03533.x
- Zhang, 2006, Design of a highly sensitive and specific nucleotide sensor based on photon upconverting particles, J. Am. Chem. Soc., 128, 12410, 10.1021/ja0644024 · doi:10.1021/ja0644024
- Rantanen, 2008, Fluorescence-quenching-based enzyme-activity assay by using photon upconversion, Angew. Chem. Int. Ed. Engl., 120, 3871, 10.1002/ange.200705861 · doi:10.1002/ange.200705861
- Hell, 1999, Nonlinear fluorescence through intermolecular energy transfer and resolution increase in fluorescence microscopy, Annalen der Physik, 8, 115, 10.1002/andp.19995110201 · doi:10.1002/andp.19995110201
- Tisler, 2011, Highly efficient FRET from a single nitrogen-vacancy center in nanodiamonds to a single organic molecule, ACS Nano, 5, 7893, 10.1021/nn2021259 · doi:10.1021/nn2021259
- Kohen, E., Ploem, J.S., and Hirschberg, J.G. (1989). Cell Structure and Function by Microspectrofluorimetry, Academic Press.
- Hu, 2006, Visualization of protein interactions in living cells using bimolecular fluorescence complementation (BiFC) analysis, Curr. Protoc. Cell Biol., Chapter 21, Unit 21 3
- Bianchini, 2012, Fast scanning STED and two-photon fluorescence excitation microscopy with continuous wave beam, J. Microsc., 245, 225, 10.1111/j.1365-2818.2011.03577.x · doi:10.1111/j.1365-2818.2011.03577.x
- Deng, 2010, Saturated Förster resonance energy transfer microscopy with a stimulated emission depletion beam: A pathway toward single-molecule resolution in far-field bioimaging, Opt. Lett., 35, 3862, 10.1364/OL.35.003862 · doi:10.1364/ol.35.003862
- Tian, 2009, Photoswitchable fluorescent nanoparticles: preparation, properties and applications, Chem. Phys. Chem., 10, 2577, 10.1002/cphc.200900492 · DOI
Cited by
Sasaki, S., Drummen, G. P. C., & Konishi, G.-I. (2016) · Journal of Materials Chemistry C · doi:10.1039/c5tc03933a · Cited by 1,189
Self-citationLiquid–liquid phase separation in human health and diseases
Wang, B., Zhang, L., Dai, T., Qin, Z., Lu, H., Zhang, L., & Zhou, F. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00678-1 · Cited by 725
Where is mTOR and what is it doing there?
Betz, C., & Hall, M. N. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201306041 · Cited by 527
Nanoparticles: Taking a Unique Position in Medicine
Joseph, T., Kar Mahapatra, D., Esmaeili, A., Piszczyk, Ł., Hasanin, M., Kattali, M., Haponiuk, J., & Thomas, S. (2023) · Nanomaterials · doi:10.3390/nano13030574 · Cited by 480
Tutorial: guidance for quantitative confocal microscopy
Jonkman, J., Brown, C. M., Wright, G. D., Anderson, K. I., & North, A. J. (2020) · Nature Protocols · doi:10.1038/s41596-020-0313-9 · Cited by 401
Metadata
- Authors
- Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C.
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2012-04-02
- Volume
- 17
- Issue
- 4
- Pages
- 4047-4132
- ISSN
- 1420-3049 (ISSN-L)
- OpenAlex
- W2077502289
- Cited by
- 557
- References
- 266
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.