Enzymatic Reactions in a Lab-on-Valve System: Cholesterol Evaluations
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
The micro sequential injection analysis / lab-on-valve (µSIA-LOV) system is a miniaturized SIA system resulting from the implementation of a lab-on-valve (LOV) atop of the selection valve. It integrates the detection cell and the sample processing channels into the same device, promoting the reduction of reagent consumption and waste generation, the improvement of the versatility, and the reduction of the time of analysis. All of these characteristics are really relevant to the implementation of enzymatic reactions. Additionally, the evaluation of cholesterol in serum samples is widely relevant in clinical diagnosis, since higher values of cholesterol in human blood are actually an important risk factor for cardiovascular problems. An automatic methodology was developed based on the µSIA-LOV system in order to evaluate its advantages in the implementation of enzymatic reactions performed by cholesterol esterase, cholesterol oxidase and peroxidase. Considering these reactions, the developed methodology was also used for the evaluation of cholesterol in human serum samples, showing reliable and accurate results. The developed methodology presented detection and quantification limits of 1.36 and 4.53 mg dL−1 and a linear range up to 40 mg dL−1. This work confirmed that this µSIA-LOV system is a simple, rapid, versatile, and robust analytical tool for the automatic implementation of enzymatic reactions performed by cholesterol esterase, cholesterol oxidase, and peroxidase. It is also a useful alternative methodology for the routine determinations of cholesterol in real samples, even when compared with other automatic methodologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 9
Research works printed but not linked: 38
- Silvestre, 2011, Enzyme based assays in a sequential injection format: A review, Anal. Chim. Acta, 689, 160, 10.1016/j.aca.2011.01.048 · DOI
- Araujo, 2009, Enzymatic determination of glucose in milk samples by sequential injection analysis, Anal. Sci., 25, 687, 10.2116/analsci.25.687 · doi:10.2116/analsci.25.687
- Ruzicka, 1990, Ssequential injection - A new concept for chemical sensors, process analysis and laboratory assays, Anal. Chim. Acta, 237, 329, 10.1016/S0003-2670(00)83937-9 · DOI · Paper page
- Ruzicka, 2000, Lab-on-valve: Universal microflow analyzer based on sequential and bead injection, Analyst, 125, 1053, 10.1039/b001125h · DOI · Paper page
- Decuir, 2007, Principles of micro sequential injection analysis in the lab-on-valve format andiIts introduction into a teaching laboratory, J. Flow Injection Anal., 24, 103
- Vidigal, 2008, Sequential injection-LOV format for peak height and kinetic measurement modes in the spectrophotometric enzymatic determination of ethanol: Application to different alcoholic beverages, Talanta, 77, 494, 10.1016/j.talanta.2008.03.034 · doi:10.1016/j.talanta.2008.03.034
- Chen, 2004, Accelerated micro-sequential injection in lab-on-valve format, applied to enzymatic assays, Analyst, 129, 597, 10.1039/b401831a · doi:10.1039/b401831a
- Costa, 2017, Automatic evaluation of peroxidase activity using different substrates under a micro sequential injection analysis/lab-on-valve (mu SIA-LOV) format, Microchem. J., 134, 98, 10.1016/j.microc.2017.05.010 · doi:10.1016/j.microc.2017.05.010
- Vidigal, 2010, Sequential injection lab-on-valve system for the determination of the activity of peroxidase in vegetables, J. Agric. Food Chem., 58, 2071, 10.1021/jf9035113 · doi:10.1021/jf9035113
- Vidigal, 2009, Sequential injection lab-on-valve system for the on-line monitoring of hydrogen peroxide in lens care solutions, Microchem. J., 91, 197, 10.1016/j.microc.2008.10.007 · doi:10.1016/j.microc.2008.10.007
- Chen, 2006, Automated method, based on micro-sequential injection, for the study of enzyme kinetics and inhibition, Anal. Sci., 22, 9, 10.2116/analsci.22.9 · DOI
- Pavlicek, 2013, Automated detection of organophosphate warfare gases (nerve agents) in air based on micro-SIA - lab-on-valve system, J. Appl. Biomed., 11, 27, 10.2478/v10136-012-0016-9 · doi:10.2478/v10136-012-0016-9
- Krug, 1994, Flow-injection analysis for total cholesterol with photometric detection, Anal. Chim. Acta, 287, 59, 10.1016/0003-2670(94)85101-8 · doi:10.1016/0003-2670(94)85101-8
- Suman, and Pundir, C.S. (2003). Co-immobilization of cholesterol esterase, cholesterol oxidase and peroxidase onto alkylamine glass beads for measurement of total cholesterol in serum. Curr. Appl. Phys., 3, 129–133. · doi:10.1016/s1567-1739(02)00178-5
- Allain, 1974, Enzymatic determination of total serum cholesterol, Clin. Chem., 20, 470, 10.1093/clinchem/20.4.470 · DOI · Paper page
- Tan, 1980, The effect of a high cholesterol and saturated fat diet on serum high-density lipoprotein-cholesterol, apoprotein-A-I, and apoprotein-E levels in normolipidemic humans, Am. J. Clin. Nutr., 33, 2559, 10.1093/ajcn/33.12.2559 · DOI
- Stewart, 2015, A Cholesterol biosensor based on the NIR electrogenerated-chemiluminescence (ECL) of water-soluble CdSeTe/ZnS quantum dots, Electrochim. Acta, 157, 8, 10.1016/j.electacta.2015.01.073 · DOI
- Collins, 2004, Effects of cholesterol-lowering with simvastatin on stroke and other major vascular events in 20 536 people with cerebrovascular disease or other high-risk conditions, Lancet, 363, 757, 10.1016/S0140-6736(04)15690-0 · DOI · Paper page
- Castelli, 1986, A population at risk - Prevalence of high cholesterol levels in hypertensive patients in the Framingham-study, Am. J. Med., 80, 23, 10.1016/0002-9343(86)90157-9 · DOI · Paper page
- Ezzati, 2002, Selected major risk factors and global and regional burden of disease, Lancet, 360, 1347, 10.1016/S0140-6736(02)11403-6 · DOI · Paper page
- Emanuelsson, 2018, Familial Hypercholesterolemia and risk of peripheral arterial disease and chronic kidney disease, J. Clin. Endocrinol. Metab., 103, 4491, 10.1210/jc.2018-01058 · DOI
- Karube, 1982, Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidase, Anal. Chim. Acta, 139, 127, 10.1016/S0003-2670(01)93990-X · doi:10.1016/s0003-2670(01)93990-x
- Taniguchi, 1986, Determination of cholesterol with a laboratory-built chemiluminescence system, Anal. Chim. Acta, 188, 95, 10.1016/S0003-2670(00)86033-X · doi:10.1016/s0003-2670(00)86033-x
- Malavolti, 1985, Determination of cholesterol with a microporous membrane chemiluminescence cell with cholesterol oxidase in solution, Anal. Chim. Acta, 170, 199, 10.1016/S0003-2670(00)81743-2 · doi:10.1016/s0003-2670(00)81743-2
- Gupta, 2013, Flow injection analysis of cholesterol using FFT admittance voltammetric biosensor based on MWCNT-ZnO nanoparticles, Electrochim. Acta, 100, 29, 10.1016/j.electacta.2013.03.118 · DOI
- Aggarwal, 2016, Amperometric determination of serum total cholesterol with nanoparticles of cholesterol esterase and cholesterol oxidase, Anal. Biochem., 500, 6, 10.1016/j.ab.2016.01.019 · doi:10.1016/j.ab.2016.01.019
- Zhang, 2017, Boron nitride nanosheet/CuS nanocomposites as mimetic peroxidase for sensitive colorimetric detection of cholesterol, Sens. Actuator B-Chem., 246, 118, 10.1016/j.snb.2017.02.059 · DOI
- Huang, 2017, Ultrasensitive cholesterol biosensor based on enzymatic silver deposition on gold nanoparticles modified screen-printed carbon electrode, Mater. Sci. Eng. C-Mater. Biol. Appl., 77, 1, 10.1016/j.msec.2017.03.253 · DOI
- Fernandezromero, 1987, Enzymatic determination of total cholesterol in serum by flow-injection analysis, J. Pharm. Biomed. Anal., 5, 333, 10.1016/0731-7085(87)80039-0 · doi:10.1016/0731-7085(87)80039-0
- Yao, 1988, Flow-injection system for simultaneous assay of free and total cholesterol in blood-serum by use of immobilized enzymes, Anal. Chim. Acta, 207, 319, 10.1016/S0003-2670(00)80808-9 · doi:10.1016/s0003-2670(00)80808-9
- Krug, 1992, Colorimetric determination of free and total cholesterol by flow-injection analysis with fiber optic detector, Enzyme Microb. Technol., 14, 313, 10.1016/0141-0229(92)90157-J · doi:10.1016/0141-0229(92)90157-j
- Situmorang, 1999, Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor, Talanta, 49, 639, 10.1016/S0039-9140(99)00057-0 · doi:10.1016/s0039-9140(99)00057-0
- Araujo, 1999, Monosegmented flow-analysis of serum cholesterol, Farmaco, 54, 51, 10.1016/S0014-827X(98)00093-7 · doi:10.1016/s0014-827x(98)00093-7
- Pires, 2003, A multicommuted flow procedure for the determination of cholesterol in animal blood serum by chemiluminescence, Anal. Lett., 36, 3011, 10.1081/AL-120026418 · doi:10.1081/al-120026418
- Rambaldi, 2009, Enzymatic determination of cholesterol and triglycerides in serum lipoprotein profiles by asymmetrical flow field-flow fractionation with on-line, dual detection, Anal. Chim. Acta, 654, 64, 10.1016/j.aca.2009.06.016 · DOI
- Wisitsoraat, 2010, Fast cholesterol detection using flow injection microfluidic device with functionalized carbon nanotubes based electrochemical sensor, Biosens. Bioelectron., 26, 1514, 10.1016/j.bios.2010.07.101 · DOI
- Miller, J.N., and Miller, J.C. (2010). Statistics and Chemometrics for Analytical Chemistry, Pearson Education Limited. [6th ed.].
- Richmond, 1976, Use of cholesterol oxidase for assay of total and free cholesterol in serum by continuous-flow analysis, Clin. Chem., 22, 1579, 10.1093/clinchem/22.10.1579 · DOI
Metadata
- Authors
- S. Barbosa, J., L.C. Passos, M., A. Korn, M. D. G., & M.F.S. Saraiva, M. L.
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2019-08-09
- Volume
- 24
- Issue
- 16
- Pages
- 2890
- ISSN
- 1420-3049
- Cited by
- 9
- Language
- en
- Funders
- Fundação para a Ciência e a Tecnologia (UID/QUI/50006/2019)
- European Regional Development Fund (POCI/01/0145/FEDER/007265)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzymatic Reactions in a Lab-on-Valve System: Cholesterol Evaluations. https://app.cochat.ai/papers/10.3390/molecules24162890
- The paper
- S. Barbosa, J., L.C. Passos, M., A. Korn, M. D. G., & M.F.S. Saraiva, M. L. (2019). Enzymatic Reactions in a Lab-on-Valve System: Cholesterol Evaluations. Molecules. https://doi.org/10.3390/molecules24162890
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.