Silicon Nanowires for Gas Sensing: A Review
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The unique electronic properties of semiconductor nanowires, in particular silicon nanowires (SiNWs), are attractive for the label-free, real-time, and sensitive detection of various gases. Therefore, over the past two decades, extensive efforts have been made to study the gas sensing function of NWs. This review article presents the recent developments related to the applications of SiNWs for gas sensing. The content begins with the two basic synthesis approaches (top-down and bottom-up) whereby the advantages and disadvantages of each approach have been discussed. Afterwards, the basic sensing mechanism of SiNWs for both resistor and field effect transistor designs have been briefly described whereby the sensitivity and selectivity to gases after different functionalization methods have been further presented. In the final words, the challenges and future opportunities of SiNWs for gas sensing have been discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physics of Semiconductor Devices
Sze, S. M., & Ng, K. K. (2006) · doi:10.1002/0470068329 · Cited by 14,627
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Room-temperature gas sensing of ZnO-based gas sensor: A review
Zhu, L., & Zeng, W. (2017) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2017.10.021 · Cited by 1,105
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Design of highly porous SnO2-CuO nanotubes for enhancing H2S gas sensor performance
Park, K.-R., Cho, H.-B., Lee, J., Song, Y., Kim, W.-B., & Choa, Y.-H. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127179 · Cited by 260
Shehada, N., Brönstrup, G., Funka, K., Christiansen, S., Leja, M., & Haick, H. (2015) · Nano Letters · doi:10.1021/nl504482t · Cited by 255 · cited 1×
“5 μm Different modification RT Cancer (VOC) Different for every gas Different VOCs; selectivity depends on learning process and used type of signal [171]”
MethodArtificial sensing intelligence with silicon nanowires for ultraselective detection in the gas phase
Wang, B., Cancilla, J. C., Torrecilla, J. S., & Haick, H. (2014) · Nano Letters · doi:10.1021/nl404335p · Cited by 236 · cited 1×
“5 μm Different modification RT VOC Different for every gas Different VOCs; selectivity depends on learning process and used type of signal [169]”
MethodSilicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
Shehada, N., Cancilla, J. C., Torrecilla, J. S., Pariente, E. S., Brönstrup, G., Christiansen, S., Johnson, D. W., Leja, M., Davies, M. P. A., Liran, O., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b03127 · Cited by 227 · cited 2×
“5 μm Different modification RT VOC Different for every gas Different VOCs; selectivity depends on learning process and used type of signal [28]”
BackgroundMethodBeyond EUV lithography: a comparative study of efficient photoresists' performance
Mojarad, N., Gobrecht, J., & Ekinci, Y. (2015) · Scientific Reports · doi:10.1038/srep09235 · Cited by 162
EUV lithography performance for manufacturing: status and outlook
Pirati, A., Peeters, R., Smith, D., Lok, S., van Noordenburg, M., van Es, R., Verhoeven, E., Meijer, H., Minnaert, A., van der Horst, J.-W., et al. (2016) · SPIE Proceedings · doi:10.1117/12.2220423 · Cited by 95 · cited 1×
“, power source, resists, and mask infrastructure [61,62].”
BackgroundShalev, G., Landman, G., Amit, I., Rosenwaks, Y., & Levy, I. (2013) · NPG Asia Materials · doi:10.1038/am.2012.75 · Cited by 61
Cited by
Wahab, A., Muhammad, M., Ullah, S., Abdi, G., Shah, G. M., Zaman, W., & Ayaz, A. (2024) · Science of The Total Environment · doi:10.1016/j.scitotenv.2024.171862 · Cited by 287
Metadata
- Authors
- Akbari-Saatlu, M., Procek, M., Mattsson, C., Thungström, G., Nilsson, H.-E., Xiong, W., Xu, B., Li, Y., & Radamson, H. H.
- Venue
- Nanomaterials
- Publisher
- MDPI AG
- Published
- 2020-11-06
- Volume
- 10
- Issue
- 11
- Pages
- 2215
- ISSN
- 2079-4991 (ISSN-L)
- OpenAlex
- W3096998184
- Cited by
- 159
- References
- 11
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.