CoChat

Analytical Performance Specifications for 25-Hydroxyvitamin D Examinations

Open access

The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.

Abstract

Currently the 25-hydroxy vitamin D (25(OH)D) concentration is thought to be the best estimate of the vitamin D status of an individual. Unfortunately, its measurement remains complex, despite recent technological advances. We evaluated the biological variation (BV) of 25(OH)D in order to set analytical performance specifications (APS) for measurement uncertainty (MU). Six European laboratories recruited 91 healthy participants. The 25(OH)D concentrations in K3-EDTA plasma were examined weekly for up to 10 weeks in duplicate on a Lumipulse G1200 (Fujirebio, Tokyo, Japan). The linear regression of the mean 25(OH)D concentrations at each blood collection showed that participants were not in a steady state. The dissection of the 10-sample collection into two subsets, namely collections 1–5 and 6–10, did not allow for correction of the lack of homogeneity: estimates of the within-subject BV ranged from 5.8% to 7.1% and the between-subject BV ranged from 25.0% to 39.2%. Methods that would differentiate a difference induced by 25(OH)D supplementation at p < 0.05 should have MU < 13.6%, while at p < 0.01, the MU should be <9.6%. The development of APS using BV assumes a steady state of patients. The findings in this study suggest that patients are not in steady state. Therefore, APS that are based on MU appear to be more appropriate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/nu13020431

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Selection of the participants for the European Federation of Clinical Chemistry and Laboratory Medicine European Biological Variation Study (EuBIVAS) study. ALAT: alanine aminotransferase; CK: creatinine kinase; CRP: C-reactive protein.
Figure 1 Selection of the participants for the European Federation of Clinical Chemistry and Laboratory Medicine European Biological Variation Study (EuBIVAS) study. ALAT: alanine aminotransferase; CK: creatinine kinase; CRP: C-reactive protein.CC BY · PubMed Central
Figure 2 An x/y plot for vitamin D mean values (Y) versus blood collections (X), according to the countries. Linear regression equation and Pearson correlation coefficient (r) produced the following: Milan, Italy: Y (ng/mL) = 0.61 × (0.44 − 0.79) + 13.5 (12.4 − 14.5), r = 0.943; Bergen, Norway: Y (ng/mL) = 0.47 × (0.22 − 0.72) + 15.7 (14.2 − 17.3), r = 0.840; Madrid, Spain: Y (ng/mL) = 0.50 × (0.38 − 0.61) + 18.7 (18.0 − 19.4), r = 0.964; Padua, Italy: Y (ng/mL) = 0.76 × (0.54 − 0.98) + 16.1 (14.8 − 17.5), r = 0.944; Istanbul, Turkey: Y (ng/mL) = 0.87 × (0.68 − 1.06) + 9.9 (8.8 − 11.1), r = 0.967; Assen, The Netherland: Y (ng/mL) = 0.68 × (0.59 − 0.78) + 21.0 (20.4 − 21.5), r = 0.986.
Figure 2 An x/y plot for vitamin D mean values (Y) versus blood collections (X), according to the countries. Linear regression equation and Pearson correlation coefficient (r) produced the following: Milan, Italy: Y (ng/mL) = 0.61 × (0.44 − 0.79) + 13.5 (12.4 − 14.5), r = 0.943; Bergen, Norway: Y (ng/mL) = 0.47 × (0.22 − 0.72) + 15.7 (14.2 − 17.3), r = 0.840; Madrid, Spain: Y (ng/mL) = 0.50 × (0.38 − 0.61) + 18.7 (18.0 − 19.4), r = 0.964; Padua, Italy: Y (ng/mL) = 0.76 × (0.54 − 0.98) + 16.1 (14.8 − 17.5), r = 0.944; Istanbul, Turkey: Y (ng/mL) = 0.87 × (0.68 − 1.06) + 9.9 (8.8 − 11.1), r = 0.967; Assen, The Netherland: Y (ng/mL) = 0.68 × (0.59 − 0.78) + 21.0 (20.4 − 21.5), r = 0.986.CC BY · PubMed Central
Figure 3 An x/y plot for vitamin D mean values (Y) versus blood collections (X). Linear regression equation with 95% CI: Y (ng/mL) = 0.604 × (0.52 − 0.70) + 16.0 (15.5 − 16.5); Pearson correlation coefficient (r) = 0.985.
Figure 3 An x/y plot for vitamin D mean values (Y) versus blood collections (X). Linear regression equation with 95% CI: Y (ng/mL) = 0.604 × (0.52 − 0.70) + 16.0 (15.5 − 16.5); Pearson correlation coefficient (r) = 0.985.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

Metadata

Authors
Cavalier, E., Fraser, C., Bhattoa, H., Heijboer, A., Makris, K., Ulmer, C., Vesper, H., Vasikaran, S., Lukas, P., Delanaye, P., Carobene, A., & on behalf of the IFCC-IOF Committee for Bone Metabolism
Affiliations
  • University of Liège (BE)
  • University of Dundee (GB)
  • University of Debrecen (HU)
  • Amsterdam University Medical Centers (NL)
  • KAT General Hospital of Attica (GR)
  • Centers for Disease Control and Prevention (US)
  • Fiona Stanley Hospital (AU)
  • IRCCS Ospedale San Raffaele (IT)
Corresponding author
Cavalier, Etienne
Venue
Nutrients
Publisher
MDPI AG
Published
2021-01-28
Volume
13
Issue
2
Pages
431
ISSN
2072-6643 (ISSN-L)
OpenAlex
W3122649889
Cited by
23
References
36
Citations by year
2026: 3 · 2025: 5 · 2024: 3 · 2023: 5 · 2022: 2 · 2021: 5
FWCI
2.36
Type
journal article
Language
en
Open access
Locations
  • Nutrients (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion, other-oa)
  • Discovery Research Portal (University of Dundee) (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • University of Debrecen Electronic Archive (University of Debrecen) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • ORBi (University of Liège) (submittedVersion, other-oa)
  • Pure Amsterdam UMC (submittedVersion, cc-by)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Vitamin D Research Studies
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
25-hydroxyvitamin D, analytical performance specifications, measurement uncertainty, biological variation, vitamin D status, steady state, vitamin D supplementation
MeSH terms
Blood Specimen Collection, Humans, Models, Theoretical, Vitamin D, Linear Models, Uncertainty

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.