CoChat

Highly Functionalized Modified Metal Oxides Polymeric Sensors for Potentiometric Determination of Letrozole in Commercial Oral Tablets and Biosamples

Open access

The DOI matches its Crossref record; 53 of the 61 references it cites were found in a registry or an index; 1 of the 4 sources its claims cite were checked for support.

Abstract

The advanced and high-functional activities of magnesium oxide and copper oxide nanoparticles encourage the extensive use of these metal oxides as remarkable electroactive materials in electrochemical and sensing detections. The current study described a comparative sensing activity and selectivity of modified coated wire membrane sensors enriched with magnesium oxide and copper oxide nanoparticles for quantifying the breast cancer medication letrozole (LTZ) in its pharmaceutical form and human plasma. The fabricated sensors were based on the incorporation of LTZ with phosphomolybdic acid (PMA) to form the electroactive complex letrozole-phosphomolybate (LTZ-PM) in the presence of o-nitrophenyloctyl ether (o-NPOE) as a solvent mediator. Under optimum conditions, the modified sensors LTZ-PM-MgONPs and LTZ-PM-CuONPs demonstrated linear relationships of 1.0 × 10−8–1.0 × 10−2 and 1.0 × 10−10–1.0 × 10−2 mol L−1, respectively. Least square equations were calculated as EmV = (56.4 ± 0.7) log [LTZ] + 569.6 and EmV = (58.7 ± 0.3) log [LTZ] + 692.6 for LTZ-PM-MgONPs and LTZ-PM-CuONPs, respectively. The conventional type LTZ-PM showed a potential response EmV = (53.3 ± 0.5) log [LTZ] + 451.4 over concentration range of 1.0 × 10−6–1.0 × 10−2 mol L−1. The suggested sensors were successfully used to determine LTZ in pharmaceutical formulations and biosamples. Method validation ensured the suitability of the suggested potentiometric sensors.

Overview

CoChat Summary

TL;DR

This paper develops and compares three coated-wire potentiometric sensors for letrozole: a conventional LTZ-PM sensor and two nanoparticle-modified versions with MgO or CuO. The modified sensors, especially LTZ-PM-CuONPs, gave wider linear ranges, lower detection limits, and strong performance in tablets and human plasma.

Key findings

  • The conventional LTZ-PM sensor showed a linear range of 1.0 × 10−6–1.0 × 10−2 mol L−1 with slope 53.3 ± 0.5 mV and correlation coefficient 0.9996; the MgO- and CuO-modified sensors extended the ranges to 1.0 × 10−8–1.0 × 10−2 and 1.0 × 10−10–1.0 × 10−2 mol L−1, with slopes 56.4 ± 0.7 mV and 58.7 ± 0.5 mV and correlation coefficients 0.9998 and 0.9999.
  • Limits of detection were 5.0 × 10−7, 5.9 × 10−9, and 5.6 × 10−11 mol L−1 for LTZ-PM, LTZ-PM-MgONPs, and LTZ-PM-CuONPs, respectively.
  • In bulk drug analysis, mean percentage recoveries were 98.9 ± 0.7%, 99.6 ± 0.5%, and 99.7 ± 0.3% for the three sensors, respectively.
  • In Femara® tablets, recoveries were 99.3 ± 0.4%, 99.6 ± 0.3%, and 99.9 ± 0.2%; in 16 plasma samples, the modified sensors gave RSDs of 0.4–1.4% and 0.1–0.7% with recoveries of 98.2–99.3% and 98.9–99.9%.

Methods

  • The study fabricated three coated-wire potentiometric sensors using an ion-pair complex of letrozole with phosphomolybdic acid: one conventional PVC membrane sensor and two modified membranes containing MgO nanoparticles or CuO nanoparticles.
  • MgO and CuO nanoparticles were synthesized chemically, then characterized by UV-Vis, FT-IR, TEM, SEM, XRD, and EDX.
  • Sensor performance was evaluated by calibration curves, pH dependence, selectivity (separate solution method), response time, and validation against standards, tablets, and 16 patient plasma samples using triplicate measurements and t-tests/F-tests.

Limitations

  • The paper states that very few articles previously addressed potentiometric determination of letrozole, but it does not present this as a study limitation.
  • Evident from the text: the biosample application was limited to 16 plasma samples from women aged 25–55 years at one hospital setting, so generalizability is not established.
  • Evident from the text: the work is a method-development/validation study; it does not compare against a large independent clinical cohort or report long-term real-world deployment.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/polym13091384

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Illustrated the construction of the modified sensor and its potentiometric system.
Figure 1 Illustrated the construction of the modified sensor and its potentiometric system.CC BY · PubMed Central
Figure 2 UV-Vis spectra of the synthesized MgONPs and CuONPs, the absorbance wavelength at 200–500 nm.
Figure 2 UV-Vis spectra of the synthesized MgONPs and CuONPs, the absorbance wavelength at 200–500 nm.CC BY · PubMed Central
Figure 3 FT-IR spectra of synthesized (a) MgONPs and (b) CuONPs at a wavenumber range from 4000 to 400 cm−1.
Figure 3 FT-IR spectra of synthesized (a) MgONPs and (b) CuONPs at a wavenumber range from 4000 to 400 cm−1.CC BY · PubMed Central
Figure 4 (a,b) EDX and (c,d) XRD spectra of MgONPs and CuONPs using XRD diffractometer with Cu-kα at (k = 1.5405 A°).
Figure 4 (a,b) EDX and (c,d) XRD spectra of MgONPs and CuONPs using XRD diffractometer with Cu-kα at (k = 1.5405 A°).CC BY · PubMed Central
Figure 5 Transmission electron microscope (TEM) images of (a) MgONPs and (b) CuONPs at acceleration voltage 100 kV and magnification × 200,000.
Figure 5 Transmission electron microscope (TEM) images of (a) MgONPs and (b) CuONPs at acceleration voltage 100 kV and magnification × 200,000.CC BY · PubMed Central
Figure 6 Scanning electron microscope (SEM) images of (a) MgONPs and (b) CuONPs at acceleration voltage 15.0 kV and magnification × 30,000.
Figure 6 Scanning electron microscope (SEM) images of (a) MgONPs and (b) CuONPs at acceleration voltage 15.0 kV and magnification × 30,000.CC BY · PubMed Central
Figure 7 Calibration graphs for the determination of 1.0 × 10−8–1.0 × 10−2, 1.0 × 10−10–1.0 × 10−2 and 1.0 × 10−6–1.0 × 10−2 mol L−1 LTZ using the fabricated (a) modified LTZ-PM-MgONPs, (b) LTZ-CuONPs and (c) conventional LTZ-PM coated wire sensors, respectively.
Figure 7 Calibration graphs for the determination of 1.0 × 10−8–1.0 × 10−2, 1.0 × 10−10–1.0 × 10−2 and 1.0 × 10−6–1.0 × 10−2 mol L−1 LTZ using the fabricated (a) modified LTZ-PM-MgONPs, (b) LTZ-CuONPs and (c) conventional LTZ-PM coated wire sensors, respectively.CC BY · PubMed Central
Figure 8 Effect of pH on the fabricated conventional LTZ-PM and modified metal oxide LTZ-PM-MgONPs and LTZ-PM-CuONPs coated wire sensors using 1.0 × 10−4 mol L−1 of LTZ solution.
Figure 8 Effect of pH on the fabricated conventional LTZ-PM and modified metal oxide LTZ-PM-MgONPs and LTZ-PM-CuONPs coated wire sensors using 1.0 × 10−4 mol L−1 of LTZ solution.CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 1 Not valid · 2 Not checked · 25 Own results and interpretations

14 more claims

Create a free account to see all 29 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 10
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

1 of 1

Citations

Cites

Show all 53 references

Research works printed but not linked: 4

  1. Tamilselvi, 2015, Development and validation of HPTLC method for the determination of Letrozole in bulk and tablet dosage form, World J. Pharm. Res., 5, 884
  2. Patil, 2013, Development of UV spectrophotometric method for estimation of letrozole in pure and pharmaceutical dosage form, Indo Am. J. Pharm. Res., 3, 5541
  3. Dais, 2015, Magnesium oxide nanoparticles-synthesis and characterization, Int. J. Nano Corr. Sci. Eng., 2, 64
  4. (2005, January 4). ICH-Q2 (R1) Validation and Analytical Procedures: Text and Methodology. Proceedings of the International Conference on Harmonization Guidelines, Geneva, Switzerland.

Cited by

See all 34

Metadata

Authors
Shawky, A. M., & El-Tohamy, M. F.
Affiliations
  • Umm al-Qura University (SA)
  • King Saud University (SA)
Corresponding author
El-Tohamy, Maha Farouk
Venue
Polymers
Publisher
MDPI AG
Published
2021-04-23
Volume
13
Issue
9
Pages
1384
ISSN
2073-4360 (ISSN-L)
OpenAlex
W3159623621
Cited by
34
References
61
Citations by year
2026: 2 · 2025: 7 · 2024: 9 · 2023: 10 · 2022: 3 · 2021: 3
FWCI
1.84
Type
journal article
Language
en
Open access
Locations
  • Polymers (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Deanship of Scientific Research at Umm Al-Qura University (Grant Code 19-MED-1-01-0011)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
letrozole, potentiometric sensors, magnesium oxide nanoparticles, copper oxide nanoparticles, phosphomolybdic acid, tablets, human plasma, electroactive polymers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Functionalized Modified Metal Oxides Polymeric Sensors for Potentiometric Determination of Letrozole in Commercial Oral Tablets and Biosamples. https://app.cochat.ai/papers/10.3390/polym13091384
The paper
Shawky, A. M., & El-Tohamy, M. F. (2021). Highly Functionalized Modified Metal Oxides Polymeric Sensors for Potentiometric Determination of Letrozole in Commercial Oral Tablets and Biosamples. Polymers. https://doi.org/10.3390/polym13091384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.