Cited by 8Power Quality and HarmonicsElectromagnetic Compatibility and Noise SuppressionMultilevel Inverters and Converters

Assessment of Harmonic Mitigation in V/f Drive of Induction Motor Using an ANN-Based Hybrid Power Filter for a Wheat Flour Mill

Open access
Krishnasamy, Bhuvaneswari, Ashok, Kavithamani·2022·Processes

Abstract

Voltage/frequency (V/f) drive of a three-phase induction motor plays a crucial role in a flour mill for energy saving. Wheat consumption in India is increasing day by day, which reached 105,000 metric ton (MT) in 2021. India’s high wheat consumption and production increase flour mills. Thus, energy efficiency in a flour mill is a must in the present situation. Hence, V/f drives are widely used in flour mills. Apart from the advantages of V/f drive, electronic circuits in a drive induce harmonics in a power system. Power quality plays a vital role in a modern power system. Harmonics by V/f drive increase the current consumption, causing increased losses, cable overheating, and motor overheating, which necessitates a filter for harmonic mitigation. In this paper, an artificial neural network controller-based hybrid power filter is proposed for harmonic mitigation. A hybrid power filter (HPF) is presented to overcome the problems and achieve the active and passive power filter’s benefits. Harmonic mitigation of the proposed hybrid power filter is compared with the passive and active filter-based drives. This paper analyzes harmonic mitigation for three-phase induction motors with V/f drive installed in a 300-ton/day wheat flour mill’s purifier fan. The performance of the suggested system is analyzed under various speeds in the aspects of harmonic mitigation, reduction in current consumption, and energy saving using various filters. The entire system is developed and analyzed using MATLAB/Simulink. Energy saving is increased by around 10.97 kWh per year by HPF by means of reducing harmonics and current consumption compared to an active power filter, while it is increased by around 28.16 kWh/year compared to a passive power filter. Along with the harmonic mitigation, energy saving is also validated for various filters under various speeds.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/pr10061191

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 34

  1. Arun Shankar, V.K.; Subramaniam, U.; Padmanaban, S.; Holm-Nielsen, J.B.; Blaabjerg, F.; Paramasivam, S. Experimental investigation of power signatures for cavitation and water hammer in an industrial parallel pumping system. Energies 2019, 12, 1351. [CrossRef] · DOI
  2. Blanco, A.M.; Gupta, M.; Gil de Castro, A.; Rönnberg, S.; Meyer, J. Impact of flat-top voltage waveform distortion on harmonic current emission and summation of electronic household appliances. Renew. Energy Power Q. J. 2018, 1, 698-703. [CrossRef] · DOI
  3. Younis, S.A.; Al-Yousif, O.M. Electrical Power System Harmonics Analysis Using ETAP. Al-Rafidain Eng. J. (AREJ) 2022, 27, 90-98. [CrossRef] · DOI
  4. Carpinelli, G.; Iacovone, F.; Russo, A.; Varilone, P.; Verde, P. Analytical Modeling for Harmonic Analysis of Line Current of VSI-Fed Drives. IEEE Trans. Power Deliv. 2004, 19, 1212-1224. [CrossRef] · DOI
  5. Malik, H.; Fatema, N.; Iqbal, A. Intelligent Data Analytics for Power Quality Disturbance Diagnosis Using Extreme Learning Machine (ELM). In Intelligent Data-Analytics for Condition Monitoring, 1st ed.; Academic Press: London, UK, 2021; pp. 91-114.
  6. Hoevenaars, A.H.; Fahrney, M.; James, M.; McGraw, M. Design considerations when applying various ASD topologies to meet harmonic compliance. In Proceedings of the Record of Conference Papers Industry Applications Society 57th Annual Petroleum and Chemical Industry Conference (PCIC), San Antonio, TX, USA, 20-22 September 2010.
  7. Giannoutsos, S.V.; Manias, S.N. A systematic power-quality assessment and harmonic filter design methodology for variable- frequency drive application in marine vessels. IEEE Trans. Ind. Appl. 2015, 51, 1909-1919. [CrossRef] · DOI
  8. Hrubý, T.; Kocman, S.; Pečínka, P. Using active filter for harmonic mitigation in power grid of industry plant. In Proceedings of the 16th International Scientific Conference on Electric Power Engineering (EPE), Kouty nad Desnou, Czech Republic, 20-22 May 2015.
  9. Lin, B.-R.; Yang, B.-R.; Tsai, H.-R. Analysis and operation of hybrid active filter for harmonic elimination. Electric Power Syst. Res. 2002, 62, 191-200. [CrossRef] · DOI
  10. Hadi, A.M.; Thjeel, E.M.; Nahar, A.K. A Review of Control Technique Applied in Shunt Active Power Filter (SAPF). Eng. Tech. J. 2022, 40, 1-10. [CrossRef] · DOI
  11. Constantinescu, M.D.; Popescu, M.; Suru, C.V. Comparative Analysis of Two Methods of Calculating the Prescribed Current in a Shunt Active Filtering System. Ann. Univ. Craiova Electr. Eng. Ser. 2021, 45, 46-51. [CrossRef] · DOI
  12. Aiwa, F.F.; Alkhayyat, M.T.; Suliman, M.Y. A Review on PQ Theory Based Shunt Active Power Filter. Des. Eng. 2021, 6, 6919-6938.
  13. Babu, R.M.; Rao, M.V.G.; Rao, R.S. Battery Energy Integrated Active Power Filter for Harmonic Compensation and Active Power Injection. Sustain. Comput. Inform. Syst. 2022, 35, 100664.
  14. Hoon, Y.; Mohd Radzi, M.A.; Mohd Zainuri, M.A.A.; Zawawi, M.A.M. Shunt active power filter: A review on phase synchroniza- tion control techniques. Electronics 2019, 8, 791. [CrossRef] · DOI
  15. Madhushan Reddy, M.; Lenine, D. Power quality improvement using PQ and SRF algorithms in shunt active power filter (SAPF) with unbalanced source voltage. J. Mech. Cont. Math. Sci. 2020, 5, 40-57. [CrossRef] · DOI
  16. Agrawal, S.; Palwalia, D.K.; Kumar, M. Performance analysis of ANN based three-phase four-wire shunt active power filter for harmonic mitigation under distorted supply voltage conditions. IETE J. Res. 2019, 68, 1-9. [CrossRef] · DOI
  17. Kumar, P.; Mahajan, A. Soft computing techniques for the control of an active power filter. IEEE Trans. Power Deliv. 2008, 24, 452-461. [CrossRef] · DOI
  18. Tekwani, P.N.; Chandwani, A.; Sankar, S.; Gandhi, N.; Chauhan, S.K. Artificial neural network-based power quality compensator. Int. J. Power Electron. 2020, 11, 256-282. [CrossRef] · DOI
  19. Habbi, H.M.D.; Ajeel, H.J.; Ali, I.I. Speed control of induction motor using PI and V/F scalar vector controllers. Int. J. Comput. Appl. 2016, 151, 36-43.
  20. Chen, L.; Sun, X.; Jiang, H.; Xu, X. A high-performance control method of constant-controlled induction motor drives for electric vehicles. Math. Probl. Eng. 2014, 2014, 386174.
  21. Dems, M.; Komeza, K.; Szulakowski, J.; Kubiak, W. Increase the Efficiency of an Induction Motor Feed from Inverter for Low Frequencies by Combining Design and Control Improvements. Energies 2022, 15, 530. [CrossRef] · DOI
  22. Suetake, M.; da Silva, I.N.; Goedtel, A. Embedded DSP-based compact fuzzy system and its application for induction-motor V/f speed control. IEEE Trans. Ind. Electron. 2010, 58, 750-760. [CrossRef] · DOI
  23. Desai, S.S.; Dattesh, K.H.; Pillai, J. Design of shunt passive filter for reducing harmonic in variable frequency drives (VFDs): A Review. J. Emerg. Tech. Innovat. Res. 2019, 6, 178-183.
  24. Srivastava, K.K.; Shakil, S.; Pandey, A.V. Harmonics & its mitigation technique by passive shunt filter. Int. J. Soft Comput. Eng. 2013, 3, 325-331.
  25. Akagi, H.; Kanazawa, Y.; Nabae, A.A.H.; Kanazawa, Y.; Fugita, K.; Nabe, A. Generalised theory of instantaneous reactive power and its application. Electr. Eng. Jpn. 1983, 103, 483-490. [CrossRef] · DOI
  26. Afonso, J.L.; Pinto, J.G.; Gonçalves, H. Active power conditioners to mitigate power quality problems in industrial facilities. In Power Quality Issues, 1st ed.; Zobaa, A., Ed.; InTech: Houston, TX, USA, 2013; pp. 105-137.
  27. Chawla, P.; Lalwani, M. Analysis and simulation of reactive power theory for harmonic elimination using shunt active power filter. Int. J. Intell. Sustain. Comput. 2021, 1, 181-193.
  28. Amir, A.I.; Sreerama Kumar, R.; Yusuf, A.A.T. Modeling and Simulation of a PI Controlled Shunt Active Power Filter for Power Quality Enhancement Based on P-Q Theory. Electronics 2020, 9, 1-17.
  29. Kale, M.; Özdemir, E. Harmonic and reactive power compensation with shunt active power filter under non-ideal mains voltage. Electr. Power Syst. Res. 2005, 74, 363-370. [CrossRef] · DOI
  30. Panchbhai, A.; Parmar, S.; Prajapati, N. Shunt active filter for harmonic and reactive power compensation using pq theory. In Proceedings of the International Conference Power and Embedded Drive Control (ICPEDC), Chennai, India, 16-18 March 2017; IEEE: Piscataway, NJ, USA, 2017; pp. 260-264.
  31. Devassy, S.; Singh, B. Modified PQ-theory-based control of solar-PV-integrated UPQC-S. IEEE Trans. Ind. Appl. 2017, 53, 5031-5040. [CrossRef] · DOI
  32. Mishra, A.K.; Ray, P.K.; Mallick, R.K.; Mohanty, A.; Das, S.R. Adaptive fuzzy controlled hybrid shunt active power filter for power quality enhancement. Neural Comput. Appl. 2021, 33, 1435-1452. [CrossRef] · DOI
  33. Frifita, K.; Boussak, M. A novel strategy for high performance fault tolerant control of shunt active power filter. Electr. Eng. 2022, 1-11. [CrossRef] · DOI
  34. Kusumalatha, Y.; Obulesh, Y.P.; Saibabu, C. Harmonics Mitigation of Industrial Motor Drives with Active Power Filters in Cement Plant-A Case SStudy. Int. J. Power Electr. Drive Syst. 2012, 2, 1-8.

Cited by

Sorted by citations

Authors
Krishnasamy, B., & Ashok, K.
Affiliations
  • Department of Electrical and Electronics Engineering, Nachimuthu Polytechnic College, Tamilnadu 642003, India
  • Coimbatore Institute of Technology (IN)
Corresponding author
Krishnasamy, Bhuvaneswari
Venue
Processes
Publisher
MDPI AG
Published
2022-06-15
Volume
10
Issue
6
Pages
1191
ISSN
2227-9717 (ISSN-L)
OpenAlex
W4283008913
Cited by
8
References
0
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 1
FWCI
0.48
Type
journal article
Language
en
Open access
Locations
  • Processes (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
harmonic compensation, three-phase induction motor, hybrid power filter, neural network control, active power filter, passive power filter, power quality, energy conservation, current consumption reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review