The DOI matches its Crossref record.
A Polymer-Based Capacitive Sensing Array for Normal and Shear Force Measurement
Open accessAbstract
In this work, we present the development of a polymer-based capacitive sensing array. The proposed device is capable of measuring normal and shear forces, and can be easily realized by using micromachining techniques and flexible printed circuit board (FPCB) technologies. The sensing array consists of a polydimethlysiloxane (PDMS) structure and a FPCB. Each shear sensing element comprises four capacitive sensing cells arranged in a 2 × 2 array, and each capacitive sensing cell has two sensing electrodes and a common floating electrode. The sensing electrodes as well as the metal interconnect for signal scanning are implemented on the FPCB, while the floating electrodes are patterned on the PDMS structure. This design can effectively reduce the complexity of the capacitive structures, and thus makes the device highly manufacturable. The characteristics of the devices with different dimensions were measured and discussed. A scanning circuit was also designed and implemented. The measured maximum sensitivity is 1.67%/mN. The minimum resolvable force is 26 mN measured by the scanning circuit. The capacitance distributions induced by normal and shear forces were also successfully captured by the sensing array.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Recent Progress in Materials and Devices toward Printable and Flexible Sensors
Rim, Y. S., Bae, S., Chen, H., De Marco, N., & Yang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201505118 · Cited by 771
Self-citationFlexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Microengineering Pressure Sensor Active Layers for Improved Performance
Ruth, S. R. A., Feig, V. R., Tran, H., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003491 · Cited by 538
Recent progresses on flexible tactile sensors
Wan, Y., Wang, Y., & Guo, C. F. (2017) · Materials Today Physics · doi:10.1016/j.mtphys.2017.06.002 · Cited by 309
Metadata
- Authors
- Cheng, M.-Y., Lin, C.-L., Lai, Y.-T., & Yang, Y.-J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-11-15
- Volume
- 10
- Issue
- 11
- Pages
- 10211-10225
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2021673896
- Cited by
- 173
- References
- 0
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Polymer-Based Capacitive Sensing Array for Normal and Shear Force Measurement. https://app.cochat.ai/papers/10.3390/s101110211
- The paper
- Cheng, M.-Y., Lin, C.-L., Lai, Y.-T., & Yang, Y.-J. (2010). A Polymer-Based Capacitive Sensing Array for Normal and Shear Force Measurement. Sensors. https://doi.org/10.3390/s101110211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.