Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Open accessThe DOI matches its Crossref record; 239 of the 239 references it cites were found in a registry or an index.
Abstract
The research and development of new electronic-nose applications in the biomedical field has accelerated at a phenomenal rate over the past 25 years. Many innovative e-nose technologies have provided solutions and applications to a wide variety of complex biomedical and healthcare problems. The purposes of this review are to present a comprehensive analysis of past and recent biomedical research findings and developments of electronic-nose sensor technologies, and to identify current and future potential e-nose applications that will continue to advance the effectiveness and efficiency of biomedical treatments and healthcare services for many years. An abundance of electronic-nose applications has been developed for a variety of healthcare sectors including diagnostics, immunology, pathology, patient recovery, pharmacology, physical therapy, physiology, preventative medicine, remote healthcare, and wound and graft healing. Specific biomedical e-nose applications range from uses in biochemical testing, blood-compatibility evaluations, disease diagnoses, and drug delivery to monitoring of metabolic levels, organ dysfunctions, and patient conditions through telemedicine. This paper summarizes the major electronic-nose technologies developed for healthcare and biomedical applications since the late 1980s when electronic aroma detection technologies were first recognized to be potentially useful in providing effective solutions to problems in the healthcare industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Holdeman, L. V., Moore, W. E., & Cato, E. P. (1977) · Cited by 2,988
Acinetobacter spp. as nosocomial pathogens: microbiological, clinical, and epidemiological features
Bergogne-Bérézin, E., & Towner, K. J. (1996) · Clinical Microbiology Reviews · doi:10.1128/cmr.9.2.148 · Cited by 1,711
Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose
Persaud, K., & Dodd, G. (1982) · Nature · doi:10.1038/299352a0 · Cited by 1,592
Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring
Fine, G. F., Cavanagh, L. M., Afonja, A., & Binions, R. (2010) · Sensors · doi:10.3390/s100605469 · Cited by 1,477
A review of advanced techniques for detecting plant diseases
Sankaran, S., Mishra, A., Ehsani, R. J., & Davis, C. E. (2010) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2010.02.007 · Cited by 1,372
Common Virulence Factors for Bacterial Pathogenicity in Plants and Animals
Rahme, L. G., Stevens, E. J., Wolfort, S. F., Shao, J., Tompkins, R. G., & Ausubel, F. M. (1995) · Science · doi:10.1126/science.7604262 · Cited by 1,339
Fumonisins--novel mycotoxins with cancer-promoting activity produced by Fusarium moniliforme
Gelderblom, W. C., Jaskiewicz, K., Marasas, W. F., Thiel, P. G., Horak, R. M., Vleggaar, R., & Kriek, N. P. (1988) · Applied and Environmental Microbiology · doi:10.1128/aem.54.7.1806-1811.1988 · Cited by 1,263
A brief history of electronic noses
Gardner, J. W., & Bartlett, P. N. (1994) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(94)87085-3 · Cited by 1,255
Applications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144
Self-citation
Cited by
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Electronic noses for food quality: A review
Loutfi, A., Coradeschi, S., Mani, G. K., Shankar, P., & Rayappan, J. B. B. (2015) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2014.07.019 · Cited by 741
The scent of disease: volatile organic compounds of the human body related to disease and disorder
Shirasu, M., & Touhara, K. (2011) · Journal of Biochemistry · doi:10.1093/jb/mvr090 · Cited by 619
Fungal volatile organic compounds: A review with emphasis on their biotechnological potential
Morath, S. U., Hung, R., & Bennett, J. W. (2012) · Fungal Biology Reviews · doi:10.1016/j.fbr.2012.07.001 · Cited by 523
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Volatile Metabolites of Pathogens: A Systematic Review
Bos, L. D. J., Sterk, P. J., & Schultz, M. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003311 · Cited by 415
Electronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Wilson, A. D. (2012) · Procedia Technology · doi:10.1016/j.protcy.2012.02.101 · Cited by 268
Self-citationTowards a Chemiresistive Sensor-Integrated Electronic Nose: A Review
Chiu, S.-W., & Tang, K.-T. (2013) · Sensors · doi:10.3390/s131014214 · Cited by 242
“Recently, artificial olfaction has been developed for numerous industry applications [3], such as indoor air-quality monitoring [4], medical care [5–7], customs security [8], food quality control [9–15], environmental quality monitoring [16–18], military applications [19], and hazardous gas detection [20,21].”
BackgroundWilson, A. (2015) · Metabolites · doi:10.3390/metabo5010140 · Cited by 242
“A multitude of breath volatile metabolites have been identified as potential biomarkers of many infectious diseases and for cancer detection [8].”
BackgroundSelf-citationGas Recognition in E-Nose System: A Review
Chen, H., Huo, D., & Zhang, J. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3166530 · Cited by 216
Plant Pest Detection Using an Artificial Nose System: A Review
Cui, S., Ling, P., Zhu, H., & Keener, H. (2018) · Sensors · doi:10.3390/s18020378 · Cited by 211
Breath sensors for lung cancer diagnosis
Adiguzel, Y., & Kulah, H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.023 · Cited by 189
“Traditional Chinese medicine engaged in olfactory diagnosis as well (Wilson and Baietto, 2011).”
BackgroundInfluentialVergara, A., Fonollosa, J., Mahiques, J., Trincavelli, M., Rulkov, N., & Huerta, R. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.05.027 · Cited by 188
“Since 1982 when the first scientific publication of artificial olfaction was presented, the e-nose [1, 2] has evolved into a valuable instrument envisioned for a wide variety of applications, including, but certainly not limited to, medical diagnostics [3, 4, 5], food spoilage monitoring [6, 7, 8], quality control [9,…”
BackgroundDetection of cancer through exhaled breath: a systematic review
Krilaviciute, A., Heiss, J. A., Leja, M., Kupcinskas, J., Haick, H., & Brenner, H. (2015) · Oncotarget · doi:10.18632/oncotarget.5938 · Cited by 188
“Reviews were published on different electronic noses used until then for biomedical and other applications [71], advances in breath analysis using e-nose for detection of various diseases [72] and nanosensor technologies used for VOCs detection [45, 73].”
Electronic Nose Technology in Respiratory Diseases
Dragonieri, S., Pennazza, G., Carratu, P., & Resta, O. (2017) · Lung · doi:10.1007/s00408-017-9987-3 · Cited by 179
Wilson, A. (2018) · Sensors · doi:10.3390/s18082613 · Cited by 171
Self-citationResearch progress of electronic nose technology in exhaled breath disease analysis
Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00594-0 · Cited by 165
“The development of eNose technology in the fi eld of health care has greatly expanded 20 .”
BackgroundEditors’ Choice—Critical Review—A Critical Review of Solid State Gas Sensors
Hunter, G. W., Akbar, S., Bhansali, S., Daniele, M., Erb, P. D., Johnson, K., Liu, C.-C., Miller, D., Oralkan, O., Hesketh, P. J., et al. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab729c · Cited by 163
The Science Behind Animal-Assisted Therapy
Marcus, D. A. (2013) · Current Pain and Headache Reports · doi:10.1007/s11916-013-0322-2 · Cited by 84
Metadata
- Authors
- Wilson, A. D., & Baietto, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2011-01-19
- Volume
- 11
- Issue
- 1
- Pages
- 1105-1176
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2045917834
- Cited by
- 400
- References
- 239
- FWCI
- 16.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.