Research progress of electronic nose technology in exhaled breath disease analysis
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Exhaled breath analysis has attracted considerable attention as a noninvasive and portable health diagnosis method due to numerous advantages, such as convenience, safety, simplicity, and avoidance of discomfort. Based on many studies, exhaled breath analysis is a promising medical detection technology capable of diagnosing different diseases by analyzing the concentration, type and other characteristics of specific gases. In the existing gas analysis technology, the electronic nose (eNose) analysis method has great advantages of high sensitivity, rapid response, real-time monitoring, ease of use and portability. Herein, this review is intended to provide an overview of the application of human exhaled breath components in disease diagnosis, existing breath testing technologies and the development and research status of electronic nose technology. In the electronic nose technology section, the three aspects of sensors, algorithms and existing systems are summarized in detail. Moreover, the related challenges and limitations involved in the abovementioned technologies are also discussed. Finally, the conclusion and perspective of eNose technology are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c05657 · Cited by 384
Self-citationWearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208 · cited 1×
“Currently, more than 3000 different VOCs have been identi fi ed in breath samples 19,27 – 29 , with over 500 VOCs detected in single breath samples 27,30,31 .”
BackgroundElectronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Lekha, S., & M, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2993591 · Cited by 105 · cited 4×
“By measuring the change in resonance frequency, the mass or concentration of a speci fi c gas adsorbed can be quanti fi ed 70,81 .”
BackgroundInfluential
Metadata
- Authors
- Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R.
- Venue
- Microsystems & Nanoengineering
- Published
- 2023-10-11
- Volume
- 9
- Issue
- 1
- Pages
- 129-129
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W4387519320
- Cited by
- 165
- References
- 5
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Research progress of electronic nose technology in exhaled breath disease analysis. https://app.cochat.ai/papers/10.1038/s41378-023-00594-0
- The paper
- Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R. (2023). Research progress of electronic nose technology in exhaled breath disease analysis. Microsystems & Nanoengineering. https://doi.org/10.1038/s41378-023-00594-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.