Sensor Data Acquisition and Processing Parameters for Human Activity Classification
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
It is known that parameter selection for data sampling frequency and segmentation techniques (including different methods and window sizes) has an impact on the classification accuracy. For Ambient Assisted Living (AAL), no clear information to select these parameters exists, hence a wide variety and inconsistency across today’s literature is observed. This paper presents the empirical investigation of different data sampling rates, segmentation techniques and segmentation window sizes and their effect on the accuracy of Activity of Daily Living (ADL) event classification and computational load for two different accelerometer sensor datasets. The study is conducted using an ANalysis Of VAriance (ANOVA) based on 32 different window sizes, three different segmentation algorithm (with and without overlap, totaling in six different parameters) and six sampling frequencies for nine common classification algorithms. The classification accuracy is based on a feature vector consisting of Root Mean Square (RMS), Mean, Signal Magnitude Area (SMA), Signal Vector Magnitude (here SMV), Energy, Entropy, FFTPeak, Standard Deviation (STD). The results are presented alongside recommendations for the parameter selection on the basis of the best performing parameter combinations that are identified by means of the corresponding Pareto curve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750 · cited 1×
“Using Matlab [25], the sensor data was resampled, segmented and the data features extracted, while the Weka software package [26] provided the implementation of the classification algorithms.”
MethodActivity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147 · cited 5×
“[13] extract features from a 4 s buffer, [12] use 5 s in their research, and [7] report a window length of 6.7 s.”
BackgroundMethodInfluentialData Mining and Knowledge Discovery Handbook
(2010) · doi:10.1007/978-0-387-09823-4 · Cited by 2,190
An online algorithm for segmenting time series
Keogh, E., Chu, S., Hart, D., & Pazzani, M. (2002) · Proceedings 2001 IEEE International Conference on Data Mining · doi:10.1109/icdm.2001.989531 · Cited by 1,149 · cited 7×
“SWAB is the third segmentation technique used as part of the study presented here and was designed by [17].”
BackgroundMethodInfluentialAccurate activity recognition in a home setting
van Kasteren, T., Noulas, A., Englebienne, G., & Kröse, B. (2008) · Proceedings of the 10th international conference on Ubiquitous computing · doi:10.1145/1409635.1409637 · Cited by 874
Collecting complex activity datasets in highly rich networked sensor environments
Roggen, D., Calatroni, A., Rossi, M., Holleczek, T., Forster, K., Troster, G., Lukowicz, P., Bannach, D., Pirkl, G., Ferscha, A., et al. (2010) · 2010 Seventh International Conference on Networked Sensing Systems (INSS) · doi:10.1109/inss.2010.5573462 · Cited by 788
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551 · cited 3×
“Additionally, sampling rates above 60 Hz were excluded, as the authors concur with [8], who stated that higher sampling rates are harder to achieve with off-the-shelve-components.”
BackgroundInfluentialFine-Grained Activity Recognition by Aggregating Abstract Object Usage
Patterson, D. J., Fox, D., Kautz, H., & Philipose, M. (2005) · Ninth IEEE International Symposium on Wearable Computers (ISWC'05) · doi:10.1109/iswc.2005.22 · Cited by 452 · cited 1×
“While these researchers are using short window sizes, [20] describe the usage of a 60 s windows in the work of [22] and 74 s in [23].”
MethodActivity Recognition and Monitoring Using Multiple Sensors on Different Body Positions
Maurer, U., Smailagic, A., Siewiorek, D. P., & Deisher, M. (2006) · doi:10.21236/ada534437 · Cited by 266
Cited by
Glucotypes reveal new patterns of glucose dysregulation
Hall, H., Perelman, D., Breschi, A., Limcaoco, P., Kellogg, R., McLaughlin, T., & Snyder, M. (2018) · PLOS Biology · doi:10.1371/journal.pbio.2005143 · Cited by 326
Semi-supervised near-miss fall detection for ironworkers with a wearable inertial measurement unit
Yang, K., Ahn, C. R., Vuran, M. C., & Aria, S. S. (2016) · Automation in Construction · doi:10.1016/j.autcon.2016.04.007 · Cited by 202
“Previous studies to detect a near-miss fall based on WIMU data mostly used a threshold approach based on the sum of total body acceleration [30,31].”
MethodMiller, A., Quinn, L., Duff, S. V., & Wade, E. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176331 · Cited by 7
“These classifiers, chosen based on [23], were: Naı̈ve Bayes, SMO, IBk, KStar, Multiclass Classifier, Bagging, Decision Tree, J48 and Random Forest.”
BackgroundMethodInfluential
Metadata
- Authors
- Bersch, S., Azzi, D., Khusainov, R., Achumba, I., & Ries, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-03-04
- Volume
- 14
- Issue
- 3
- Pages
- 4239-4270
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2045830677
- Cited by
- 114
- References
- 9
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensor Data Acquisition and Processing Parameters for Human Activity Classification. https://app.cochat.ai/papers/10.3390/s140304239
- The paper
- Bersch, S., Azzi, D., Khusainov, R., Achumba, I., & Ries, J. (2014). Sensor Data Acquisition and Processing Parameters for Human Activity Classification. Sensors. https://doi.org/10.3390/s140304239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.