The DOI matches its Crossref record.
Fiber Bragg Grating Sensors toward Structural Health Monitoring in Composite Materials: Challenges and Solutions
Open accessAbstract
Nowadays, smart composite materials embed miniaturized sensors for structural health monitoring (SHM) in order to mitigate the risk of failure due to an overload or to unwanted inhomogeneity resulting from the fabrication process. Optical fiber sensors, and more particularly fiber Bragg grating (FBG) sensors, outperform traditional sensor technologies, as they are lightweight, small in size and offer convenient multiplexing capabilities with remote operation. They have thus been extensively associated to composite materials to study their behavior for further SHM purposes. This paper reviews the main challenges arising from the use of FBGs in composite materials. The focus will be made on issues related to temperature-strain discrimination, demodulation of the amplitude spectrum during and after the curing process as well as connection between the embedded optical fibers and the surroundings. The main strategies developed in each of these three topics will be summarized and compared, demonstrating the large progress that has been made in this field in the past few years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ramakrishnan, M., Rajan, G., Semenova, Y., & Farrell, G. (2016) · Sensors · doi:10.3390/s16010099 · Cited by 382
Nsengiyumva, W., Zhong, S., Lin, J., Zhang, Q., Zhong, J., & Huang, Y. (2021) · Composite Structures · doi:10.1016/j.compstruct.2020.112951 · Cited by 325
Structural Health Monitoring for Advanced Composite Structures: A Review
Güemes, A., Fernandez-Lopez, A., Pozo, A. R., & Sierra-Pérez, J. (2020) · Journal of Composites Science · doi:10.3390/jcs4010013 · Cited by 298
Medical Smart Textiles Based on Fiber Optic Technology: An Overview
Massaroni, C., Saccomandi, P., & Schena, E. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6020204 · Cited by 172
Chen, Z., Zhou, X., Wang, X., Dong, L., & Qian, Y. (2017) · Sensors · doi:10.3390/s17092151 · Cited by 128
Metadata
- Authors
- Kinet, D., Mégret, P., Goossen, K., Qiu, L., Heider, D., & Caucheteur, C.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-04-23
- Volume
- 14
- Issue
- 4
- Pages
- 7394-7419
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2060250478
- Cited by
- 523
- References
- 0
- FWCI
- 20.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fiber Bragg Grating Sensors toward Structural Health Monitoring in Composite Materials: Challenges and Solutions. https://app.cochat.ai/papers/10.3390/s140407394
- The paper
- Kinet, D., Mégret, P., Goossen, K., Qiu, L., Heider, D., & Caucheteur, C. (2014). Fiber Bragg Grating Sensors toward Structural Health Monitoring in Composite Materials: Challenges and Solutions. Sensors. https://doi.org/10.3390/s140407394
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.