The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Förster Resonance Energy Transfer between Quantum Dot Donors and Quantum Dot Acceptors
Open accessAbstract
Förster (or fluorescence) resonance energy transfer amongst semiconductor quantum dots (QDs) is reviewed, with particular interest in biosensing applications. The unique optical properties of QDs provide certain advantages and also specific challenges with regards to sensor design, compared to other FRET systems. The brightness and photostability of QDs make them attractive for highly sensitive sensing and long-term, repetitive imaging applications, respectively, but the overlapping donor and acceptor excitation signals that arise when QDs serve as both the donor and acceptor lead to high background signals from direct excitation of the acceptor. The fundamentals of FRET within a nominally homogeneous QD population as well as energy transfer between two distinct colors of QDs are discussed. Examples of successful sensors are highlighted, as is cascading FRET, which can be used for solar harvesting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
Biju, V. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60273g · Cited by 1,186
Designer polymer–quantum dot architectures
Tomczak, N., Jańczewski, D., Han, M., & Vancso, G. J. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.11.004 · Cited by 332
Cited by
Application of semiconductor quantum dots in bioimaging and biosensing
Martynenko, I. V., Litvin, A. P., Purcell-Milton, F., Baranov, A. V., Fedorov, A. V., & Gun'ko, Y. K. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01425b · Cited by 382
Fluorescence detection of pesticides using quantum dot materials – A review
Nsibande, S. A., & Forbes, P. B. C. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.002 · Cited by 283
Supraparticles: Functionality from Uniform Structural Motifs
Wintzheimer, S., Granath, T., Oppmann, M., Kister, T., Thai, T., Kraus, T., Vogel, N., & Mandel, K. (2018) · ACS Nano · doi:10.1021/acsnano.8b00873 · Cited by 253
Metadata
- Authors
- Chou, K., & Dennis, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-06-05
- Volume
- 15
- Issue
- 6
- Pages
- 13288-13325
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1555589841
- Cited by
- 302
- References
- 3
- FWCI
- 9.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Förster Resonance Energy Transfer between Quantum Dot Donors and Quantum Dot Acceptors. https://app.cochat.ai/papers/10.3390/s150613288
- The paper
- Chou, K., & Dennis, A. (2015). Förster Resonance Energy Transfer between Quantum Dot Donors and Quantum Dot Acceptors. Sensors. https://doi.org/10.3390/s150613288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.