The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Studies of Reduced Graphene Oxide and Graphite Oxide in the Aspect of Their Possible Application in Gas Sensors
Open accessAbstract
The paper presents the results of investigations on resistance structures based on graphite oxide (GRO) and graphene oxide (rGO). The subject matter of the investigations was thaw the sensitivity of the tested structures was affected by hydrogen, nitrogen dioxide and carbon dioxide. The experiments were performed at a temperature range from 30 °C to 150 °C in two carrier gases: nitrogen and synthetic air. The measurements were also aimed at characterization of the graphite oxide and graphene oxide. In our measurements we used (among others) techniques such as: Atomic Force Microscopy (AFM); Scanning Electron Microscopy (SEM); Raman Spectroscopy (RS); Fourier Transform Infrared Spectroscopy (FT-IR) and X-ray Photoelectron Microscopy (XPS). The data resulting from the characterizations of graphite oxide and graphene oxide have made it possible to interpret the obtained results from the point of view of physicochemical changes occurring in these structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Graphene Oxide Molecular Sensors
Robinson, J. T., Perkins, F. K., Snow, E. S., Wei, Z., & Sheehan, P. E. (2008) · Nano Letters · doi:10.1021/nl8013007 · Cited by 1,772
A new structural model for graphite oxide
He, H., Klinowski, J., Forster, M., & Lerf, A. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00144-4 · Cited by 1,517
Hontoria-Lucas, C., López-Peinado, A. J., López-González, J. D. D., Rojas-Cervantes, M. L., & Martín-Aranda, R. M. (1995) · Carbon · doi:10.1016/0008-6223(95)00120-3 · Cited by 1,079
Hydrogen Bond Networks in Graphene Oxide Composite Paper: Structure and Mechanical Properties
Medhekar, N. V., Ramasubramaniam, A., Ruoff, R. S., & Shenoy, V. B. (2010) · ACS Nano · doi:10.1021/nn901934u · Cited by 803
Reduced graphene oxide for room-temperature gas sensors
Lu, G., Ocola, L. E., & Chen, J. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/44/445502 · Cited by 775
Direct Power Generation from a Graphene Oxide Film under Moisture
Zhao, F., Cheng, H., Zhang, Z., Jiang, L., & Qu, L. (2015) · Advanced Materials · doi:10.1002/adma.201501867 · Cited by 745
Graphene-based electronic sensors
He, Q., Wu, S., Yin, Z., & Zhang, H. (2012) · Chemical Science · doi:10.1039/c2sc20205k · Cited by 745
Graphene production via electrochemical reduction of graphene oxide: Synthesis and characterisation
Toh, S. Y., Loh, K. S., Kamarudin, S. K., & Daud, W. R. W. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.04.004 · Cited by 661
Visualization of defect densities in reduced graphene oxide
Eigler, S., Dotzer, C., & Hirsch, A. (2012) · Carbon · doi:10.1016/j.carbon.2012.03.039 · Cited by 576
Botas, C., Álvarez, P., Blanco, P., Granda, M., Blanco, C., Santamaría, R., Romasanta, L. J., Verdejo, R., López-Manchado, M. A., & Menéndez, R. (2013) · Carbon · doi:10.1016/j.carbon.2013.08.009 · Cited by 427
Gas detection using low-temperature reduced graphene oxide sheets
Lu, G., Ocola, L. E., & Chen, J. (2009) · Applied Physics Letters · doi:10.1063/1.3086896 · Cited by 418
Lu, G., Park, S., Yu, K., Ruoff, R. S., Ocola, L. E., Rosenmann, D., & Chen, J. (2011) · ACS Nano · doi:10.1021/nn102803q · Cited by 378
Kaniyoor, A., Imran Jafri, R., Arockiadoss, T., & Ramaprabhu, S. (2009) · Nanoscale · doi:10.1039/b9nr00015a · Cited by 371
Graphene-based nitrogen dioxide gas sensors
Ko, G., Kim, H.-Y., Ahn, J., Park, Y.-M., Lee, K.-Y., & Kim, J. (2010) · Current Applied Physics · doi:10.1016/j.cap.2009.12.024 · Cited by 336
A practical carbon dioxide gas sensor using room-temperature hydrogen plasma reduced graphene oxide
Muhammad Hafiz, S., Ritikos, R., Whitcher, T. J., Md. Razib, N., Bien, D. C. S., Chanlek, N., Nakajima, H., Saisopa, T., Songsiriritthigul, P., Huang, N. M., et al. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.12.017 · Cited by 332
Ultrafast and sensitive room temperature NH3 gas sensors based on chemically reduced graphene oxide
Hu, N., Yang, Z., Wang, Y., Zhang, L., Wang, Y., Huang, X., Wei, H., Wei, L., & Zhang, Y. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/2/025502 · Cited by 281
Revisiting the chemistry of graphite oxides and its effect on ammonia adsorption
Petit, C., Seredych, M., & Bandosz, T. J. (2009) · Journal of Materials Chemistry · doi:10.1039/b916672f · Cited by 269
The structure of graphene oxide membranes in liquid water, ethanol and water–ethanol mixtures
Talyzin, A. V., Hausmaninger, T., You, S., & Szabó, T. (2014) · Nanoscale · doi:10.1039/c3nr04631a · Cited by 197
Fan, X., Yu, C., Yang, J., Ling, Z., & Qiu, J. (2014) · Carbon · doi:10.1016/j.carbon.2013.12.081 · Cited by 190
Hydrogen sensor based on a graphene – palladium nanocomposite
Lange, U., Hirsch, T., Mirsky, V. M., & Wolfbeis, O. S. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2010.10.078 · Cited by 180
Towards low temperature thermal exfoliation of graphite oxide for graphene production
Zhang, C., Lv, W., Xie, X., Tang, D., Liu, C., & Yang, Q.-H. (2013) · Carbon · doi:10.1016/j.carbon.2013.05.033 · Cited by 164
Reduced graphene oxide filled cellulose films for flexible temperature sensor application
Sadasivuni, K. K., Kafy, A., Kim, H. C., Ko, H., Mun, S., & Kim, J. (2015) · Synthetic Metals · doi:10.1016/j.synthmet.2015.05.018 · Cited by 148
In vitro and in vivo effects of graphene oxide and reduced graphene oxide on glioblastoma
Chwalibóg, A., Jaworski, S., Sawosz, E., Kutwin, M., Wierzbicki, M., Hinzmann, M., Grodzik, M., Winnicka, A., Lipińska, L., & Włodyga, K. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s77591 · Cited by 125
O’Neill, A., Bakirtzis, D., & Dixon, D. (2014) · European Polymer Journal · doi:10.1016/j.eurpolymj.2014.07.038 · Cited by 116
Mo, Z., Zheng, R., Peng, H., Liang, H., & Liao, S. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.07.038 · Cited by 115
Characterization of partially reduced graphene oxide as room temperature sensor for H2
Zhang, L.-S., Wang, W. D., Liang, X.-Q., Chu, W.-S., Song, W.-G., Wang, W., & Wu, Z.-Y. (2011) · Nanoscale · doi:10.1039/c1nr10187k · Cited by 77
Rodriguez‐Pastor, I., Ramos‐Fernandez, G., Varela‐Rizo, H., Terrones, M., & Martı́n-Gullón, I. (2014) · Carbon · doi:10.1016/j.carbon.2014.12.027 · Cited by 68
Delamination of graphite oxide in a liquid upon cooling
Talyzin, A. V., Klechikov, A. G., Korobov, M. V., Ребрикова, А. Т., Avramenko, N. V., Gholami, M. F., Severin, N., & Rabe, J. P. (2015) · Nanoscale · doi:10.1039/c5nr02564h · Cited by 49
Kim, W. J., Basavaraja, C., Thinh, P. X., & Huh, D. S. (2013) · Materials Letters · doi:10.1016/j.matlet.2012.09.007 · Cited by 14
Cited by
Sharma, N., Sharma, V., Jain, Y., Kumari, M., Gupta, R., Sharma, S. K., & Sachdev, K. (2017) · Macromolecular Symposia · doi:10.1002/masy.201700006 · Cited by 575
Microfluidization of Graphite and Formulation of Graphene-Based Conductive Inks
Karagiannidis, P. G., Hodge, S. A., Lombardi, L., Tomarchio, F., Decorde, N., Milana, S., Goykhman, I., Su, Y., Mesite, S. V., Johnstone, D. N., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b07735 · Cited by 348
Metadata
- Authors
- Drewniak, S., Muzyka, R., Stolarczyk, A., Pustelny, T., Kotyczka-Morańska, M., & Setkiewicz, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-01-15
- Volume
- 16
- Issue
- 1
- Pages
- 103
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2233797376
- Cited by
- 351
- References
- 29
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.