Giant Magnetoresistance: Basic Concepts, Microstructure, Magnetic Interactions and Applications
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The giant magnetoresistance (GMR) effect is a very basic phenomenon that occurs in magnetic materials ranging from nanoparticles over multilayered thin films to permanent magnets. In this contribution, we first focus on the links between effect characteristic and underlying microstructure. Thereafter, we discuss design criteria for GMR-sensor applications covering automotive, biosensors as well as nanoparticular sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kubo, R. (1957) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.12.570 · Cited by 9,441 · cited 1×
“The Kubo formalism [8] uses linear response theory to calculate the effect of small electric fields on currents.”
MethodGiant Magnetoresistance of (001)Fe/(001)Cr Magnetic Superlattices
Baibich, M. N., Broto, J. M., Fert, A., Van Dau, F. N., Petroff, F., Etienne, P., Creuzet, G., Friederich, A., & Chazelas, J. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2472 · Cited by 9,415 · cited 1×
“It has been almost 30 years since one of the most fascinating advances in solid state physics occurred, the discovery of the giant magnetoresistance effect (GMR) by Grünberg and Fert in 1988 [1,2].”
BackgroundNogués, J., & Schuller, I. K. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00266-2 · Cited by 4,677
Enhanced magnetoresistance in layered magnetic structures with antiferromagnetic interlayer exchange
Binasch, G., Grünberg, P., Saurenbach, F., & Zinn, W. (1989) · Physical Review B · doi:10.1103/physrevb.39.4828 · Cited by 4,347 · cited 1×
“It has been almost 30 years since one of the most fascinating advances in solid state physics occurred, the discovery of the giant magnetoresistance effect (GMR) by Grünberg and Fert in 1988 [1,2].”
BackgroundThe mean free path of electrons in metals
Sondheimer, E. H. (1952) · Advances in Physics · doi:10.1080/00018735200101151 · Cited by 2,614
The conductivity of thin metallic films according to the electron theory of metals
Fuchs, K. (1938) · Mathematical Proceedings of the Cambridge Philosophical Society · doi:10.1017/s0305004100019952 · Cited by 2,276 · cited 1×
“The model builds on the work of Fuchs and Sondheimer who used it to calculate the dependence of film thickness on the conductivity of thin metal films [13,14].”
MethodGiant magnetoresistance in heterogeneous Cu-Co alloys
Berkowitz, A. E., Mitchell, J. R., Carey, M. J., Young, A. P., Zhang, S., Spada, F. E., Parker, F. T., Hütten, A., & Thomas, G. J. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.3745 · Cited by 1,854 · cited 3×
“While a constant decrease of the granular GMR with increasing particle size w s observed by some groups [81,91,92], it was found in refs.”
BackgroundSelf-citationGiant magnetoresistance in nonmultilayer magnetic systems
Xiao, J. Q., Jiang, J. S., & Chien, C. L. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.3749 · Cited by 1,790 · cited 9×
“They found their model to be in agreement with data by Xiao, Jiang and Chien [19], but as approaches 1, the GMR deviated from ∝ ( ( ) → ).”
BackgroundResultInfluentialTheory of the perpendicular magnetoresistance in magnetic multilayers
Valet, T., & Fert, A. (1993) · Physical Review B · doi:10.1103/physrevb.48.7099 · Cited by 1,731 · cited 2×
“, for thicknesses of a couple of hundreds of angstroms, the contribution from bulk scattering becomes predominant [15].”
BackgroundMethodMolecular Rulers for Scaling Down Nanostructures
Hatzor, A., & Weiss, P. S. (2001) · Science · doi:10.1126/science.1057553 · Cited by 1,681 · cited 5×
“This crystallographic reorientation is triggered by the minimization of lattice mismatch elastic energy: Under equal strain the elastic energy in a [111] oriented CoCu material is higher than the energy in a [100] structure due to the elastic”
BackgroundMethodInfluentialArtificial Brownian motors: Controlling transport on the nanoscale
Hänggi, P., & Marchesoni, F. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.387 · Cited by 1,573 · cited 1×
“A new concept to transport the magnetic particles in a “lab on a chip” environment without the need of external forces like microfluidic pumps, is a magnetic on-off ratchet [79,80].”
BackgroundColloidal Nanocrystal Shape and Size Control: The Case of Cobalt
Puntes, V. F., Krishnan, K. M., & Alivisatos, A. P. (2001) · Science · doi:10.1126/science.1058495 · Cited by 869
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Magnetotransport properties of magnetically soft spin-valve structures (invited)
Dieny, B., Speriosu, V. S., Metin, S., Parkin, S. S. P., Gurney, B. A., Baumgart, P., & Wilhoit, D. R. (1991) · Journal of Applied Physics · doi:10.1063/1.348252 · Cited by 570
Magnetoresistive-based biosensors and biochips
Graham, D. L., Ferreira, H. A., & Freitas, P. P. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.06.006 · Cited by 435
Perpendicular giant magnetoresistance of magnetic multilayers
Gijs, M. A. M., & Bauer, G. E. W. (1997) · Advances in Physics · doi:10.1080/00018739700101518 · Cited by 316 · cited 1×
“A detailed description and additional literature may be obtained in the extensive treatment of CPP GMR in multilayers by Gijs and Bauer [12].”
MethodPuntes, V. F., Krishnan, K. M., & Alivisatos, P. (2001) · Applied Physics Letters · doi:10.1063/1.1362333 · Cited by 306 · cited 1×
“For preparation of the hybrid system, Co nanoparticles with a mean diameter of 12 nm have been prepared via a wet chemical synthesis [111,112].”
MethodPerspectives of giant magnetoresistance
Tsymbal, E. Y., & Pettifor, D. G. (2001) · Solid State Physics · doi:10.1016/s0081-1947(01)80019-9 · Cited by 284 · cited 3×
“Nevertheless, when it comes to detail, discrepancies between experimental observations and theoretical models can arise: a realistic theoretical description of electron scattering at lattice discontinuities, disorder or defects is still a crucial factor [6,7].”
BackgroundMicroelectromagnets for the control of magnetic nanoparticles
Lee, C. S., Lee, H., & Westervelt, R. M. (2001) · Applied Physics Letters · doi:10.1063/1.1419049 · Cited by 279
Extraordinary Hall effect and giant magnetoresistance in the granular Co-Ag system
Xiong, P., Xiao, G., Wang, J. Q., Xiao, J. Q., Jiang, J. S., & Chien, C. L. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.3220 · Cited by 257
Giant Magnetoresistance in Magnetic Nanostructures
Parkin, S. S. P. (1995) · Annual Review of Materials Science · doi:10.1146/annurev.ms.25.080195.002041 · Cited by 228 · cited 3×
“Driven by possible applications as sensors in automotive and read-head industry, numerous studies have been performed to improve the GMR characteristic since then [6,7,28].”
BackgroundGiant Magnetoresistance-based Biosensor for Detection of Influenza A Virus
Krishna, V. D., Wu, K., Perez, A. M., & Wang, J.-P. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.00400 · Cited by 178
Magnetic superlattices and multilayers
Schuller, I. K., Kim, S., & Leighton, C. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00336-4 · Cited by 160 · cited 2×
“Nevertheless, when it comes to detail, discrepancies between experimental observations and theoretical models can arise: a realistic theoretical description of electron scattering at lattice discontinuities, disorder or defects is still a crucial factor [6,7].”
BackgroundNew magnetic nanoparticles for biotechnology
Hütten, A., Sudfeld, D., Ennen, I., Reiss, G., Hachmann, W., Heinzmann, U., Wojczykowski, K., Jutzi, P., Saikaly, W., & Thomas, G. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.04.019 · Cited by 159 · cited 1×
“Chemically synthesized FeCo nanoparticles are good candidates even for single molecule detection as well, due to their superior saturation magnetization and, therefore, larger stray fields [64]; (2) the interface between chemistry and biology has to be fitted for each application, to allow a specific functionalization…”
BackgroundSelf-citationUltrasonic deposition of cells on a surface
Hawkes, J. J., Long, M., Coakley, W. T., & McDonnell, M. B. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.10.003 · Cited by 89 · cited 1×
“Another way to concentrate beads on a sensing surface uses of ultrasonic standing waves inside a microfluidic channel system [76,77] or the microfluidic system itself can be utilized to transport beads towards the sensor surface, e.”
MethodMagnetrresistive properties and thermal stability of Ni-Fe/Ag multilayers
Rodmacq, B., Palumbo, G., & Gérard, P. (1993) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(93)90149-v · Cited by 82
Review and outlook: from single nanoparticles to self-assembled monolayers and granular GMR sensors
Weddemann, A., Ennen, I., Regtmeier, A., Albon, C., Wolff, A., Eckstädt, K., Mill, N., Peter, M., Mattay, J., Plattner, C., et al. (2010) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.1.10 · Cited by 67 · cited 4×
“Caused by a dipolar coupling of adjacent particles, magnetic domains can be formed with an antiparallel arrangement of magnetic moments which maintains a higher stability against external influences compared to the non-interacting particles [121].”
BackgroundMethodInfluentialSelf-citationMagnetic separation from superparamagnetic particle suspensions
Sinha, A., Ganguly, R., & Puri, I. K. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.01.034 · Cited by 65
Giant magnetoresistance and superparamagnetic grains in Co–Ag granular films
Honda, S., Nawate, M., Tanaka, M., & Okada, T. (1997) · Journal of Applied Physics · doi:10.1063/1.365770 · Cited by 65
Tan, R. P., Carrey, J., Desvaux, C., Grisolia, J., Renaud, P., Chaudret, B. N., & Respaud, M. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.176805 · Cited by 49
Antibody immobilization on magnetic particles
Roque, A. C. A., Bispo, S., Pinheiro, A. R. N., Antunes, J. M. A., Gonçalves, D., & Ferreira, H. A. (2008) · Journal of Molecular Recognition · doi:10.1002/jmr.913 · Cited by 41 · cited 1×
“, for the detection of biotin-labeled DNA, streptavidin coated particles can be used [65,66]; (3) the GMR sensors have to be incorporated in fluidic environments, which enable the magnetic markers to pass the sensor surfaces at close distances to ensure a binding onto the surface within an acceptable time scale [67].”
Thickness dependence of magneto-transport in Cu-Co granular thin films
Wang, J., Dao, N., Kim, N. H., & Whittenburg, S. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1664171 · Cited by 13
Cited by
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“, rotated), then the ohmic resistance to a current Iexc flowing in the thin film perpendicularly to the applied external magnetic field Hext is modulated [87].”
BackgroundPrinciples of spintronic THz emitters
Wu, W., Yaw Ameyaw, C., Doty, M. F., & Jungfleisch, M. B. (2021) · Journal of Applied Physics · doi:10.1063/5.0057536 · Cited by 84
Metadata
- Authors
- Ennen, I., Kappe, D., Rempel, T., Glenske, C., & Hütten, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-06-17
- Volume
- 16
- Issue
- 6
- Pages
- 904
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2422623101
- Cited by
- 194
- References
- 32
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.