The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview
Open accessAbstract
During recent decades, minimally invasive thermal treatments (i.e., Radiofrequency ablation, Laser ablation, Microwave ablation, High Intensity Focused Ultrasound ablation, and Cryo-ablation) have gained widespread recognition in the field of tumor removal. These techniques induce a localized temperature increase or decrease to remove the tumor while the surrounding healthy tissue remains intact. An accurate measurement of tissue temperature may be particularly beneficial to improve treatment outcomes, because it can be used as a clear end-point to achieve complete tumor ablation and minimize recurrence. Among the several thermometric techniques used in this field, fiber optic sensors (FOSs) have several attractive features: high flexibility and small size of both sensor and cabling, allowing insertion of FOSs within deep-seated tissue; metrological characteristics, such as accuracy (better than 1 °C), sensitivity (e.g., 10 pm·°C−1 for Fiber Bragg Gratings), and frequency response (hundreds of kHz), are adequate for this application; immunity to electromagnetic interference allows the use of FOSs during Magnetic Resonance- or Computed Tomography-guided thermal procedures. In this review the current status of the most used FOSs for temperature monitoring during thermal procedure (e.g., fiber Bragg Grating sensors; fluoroptic sensors) is presented, with emphasis placed on their working principles and metrological characteristics. The essential physics of the common ablation techniques are included to explain the advantages of using FOSs during these procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ranjan, A., Jacobs, G. C., Woods, D. L., Negussie, A. H., Partanen, A., Yarmolenko, P. S., Gacchina, C. E., Sharma, K. V., Frenkel, V., Wood, B. J., et al. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.12.011 · Cited by 267 · cited 2×
“, 2012 [92] Fluoroptic sensors HIFU in vivo rabbit Vx2 tumor models Neoptix T1 probe, Fluoroptic sensors”
Cited by
Lanthanide‐Based Thermometers: At the Cutting‐Edge of Luminescence Thermometry
Brites, C. D. S., Balabhadra, S., & Carlos, L. D. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801239 · Cited by 1,173
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Self-citationFiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Lo Presti, D., Massaroni, C., Jorge Leitão, C. S., De Fátima Domingues, M., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3019138 · Cited by 377
Self-citation
Metadata
- Authors
- Schena, E., Tosi, D., Saccomandi, P., Lewis, E., & Kim, T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-07-22
- Volume
- 16
- Issue
- 7
- Pages
- 1144
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2491889723
- Cited by
- 238
- References
- 1
- FWCI
- 12.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview. https://app.cochat.ai/papers/10.3390/s16071144
- The paper
- Schena, E., Tosi, D., Saccomandi, P., Lewis, E., & Kim, T. (2016). Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview. Sensors. https://doi.org/10.3390/s16071144
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.