Contact-Based Methods for Measuring Respiratory Rate
Open accessAbstract
There is an ever-growing demand for measuring respiratory variables during a variety of applications, including monitoring in clinical and occupational settings, and during sporting activities and exercise. Special attention is devoted to the monitoring of respiratory rate because it is a vital sign, which responds to a variety of stressors. There are different methods for measuring respiratory rate, which can be classed as contact-based or contactless. The present paper provides an overview of the currently available contact-based methods for measuring respiratory rate. For these methods, the sensing element (or part of the instrument containing it) is attached to the subject’s body. Methods based upon the recording of respiratory airflow, sounds, air temperature, air humidity, air components, chest wall movements, and modulation of the cardiac activity are presented. Working principles, metrological characteristics, and applications in the respiratory monitoring field are presented to explore potential development and applicability for each method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Micromachined inertial sensors
Yazdi, N., Ayazi, F., & Najafi, K. (1998) · Proceedings of the IEEE · doi:10.1109/5.704269 · Cited by 1,823
Humidity Sensors Principle, Mechanism, and Fabrication Technologies: A Comprehensive Review
Farahani, H., Wagiran, R., & Hamidon, M. (2014) · Sensors · doi:10.3390/s140507881 · Cited by 1,286
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
The Measurement, Instrumentation and Sensors Handbook
Webster, J. G. (1998) · CRC Press eBooks · doi:10.1201/9781003040019 · Cited by 1,029
BERNTSON, G. G., CACIOPPO, J. T., & QUIGLEY, K. S. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb01731.x · Cited by 998
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 3×
“, the green-yellow region of the visible spectrum) at the tissue [233], and (ii) one photodetector, PD, to record the intensity of the non-absorbed light reflected from the tissue [246].”
BackgroundMethodRespiratory rate: the neglected vital sign
Cretikos, M. A., Bellomo, R., Hillman, K., Chen, J., Finfer, S., & Flabouris, A. (2008) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2008.tb01825.x · Cited by 889
Cited by
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Self-citationWearable System Based on Flexible FBG for Respiratory and Cardiac Monitoring
Lo Presti, D., Massaroni, C., D'Abbraccio, J., Massari, L., Caponero, M., Longo, U. G., Formica, D., Oddo, C. M., & Schena, E. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2916320 · Cited by 219
Self-citationFiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2988692 · Cited by 128
Self-citationLo Presti, D., Romano, C., Massaroni, C., D’Abbraccio, J., Massari, L., Caponero, M. A., Oddo, C. M., Formica, D., & Schena, E. (2019) · Sensors · doi:10.3390/s19163581 · Cited by 126
Self-citationKlum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75
Metadata
- Authors
- Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-02-21
- Volume
- 19
- Issue
- 4
- Pages
- 908
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2917388343
- Cited by
- 426
- References
- 180
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contact-Based Methods for Measuring Respiratory Rate. https://app.cochat.ai/papers/10.3390/s19040908
- The paper
- Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019). Contact-Based Methods for Measuring Respiratory Rate. Sensors. https://doi.org/10.3390/s19040908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.