The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Flexible and Highly Sensitive Pressure Sensor Based on a PDMS Foam Coated with Graphene Nanoplatelets
Open accessAbstract
The demand for high performance multifunctional wearable devices is more and more pushing towards the development of novel low-cost, soft and flexible sensors with high sensitivity. In the present work, we describe the fabrication process and the properties of new polydimethylsiloxane (PDMS) foams loaded with multilayer graphene nanoplatelets (MLGs) for application as high sensitive piezoresistive pressure sensors. The effective DC conductivity of the produced foams is measured as a function of MLG loading. The piezoresistive response of the MLG-PDMS foam-based sensor at different strain rates is assessed through quasi-static pressure tests. The results of the experimental investigations demonstrated that sensor loaded with 0.96 wt.% of MLGs is characterized by a highly repeatable pressure-dependent conductance after a few stabilization cycles and it is suitable for detecting compressive stresses as low as 10 kPa, with a sensitivity of 0.23 kPa−1, corresponding to an applied pressure of 70 kPa. Moreover, it is estimated that the sensor is able to detect pressure variations of ~1 Pa. Therefore, the new graphene-PDMS composite foam is a lightweight cost-effective material, suitable for sensing applications in the subtle or low and medium pressure ranges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · cited 2×
“The obtained results reporte in Figure 18 show that S assumes a constant value in each operating pressure range [36].”
ResultSolvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501
Cited by
Graphene-Paper Pressure Sensor for Detecting Human Motions
Tao, L.-Q., Zhang, K.-N., Tian, H., Liu, Y., Wang, D.-Y., Chen, Y.-Q., Yang, Y., & Ren, T.-L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02826 · Cited by 738
Theory, technology and applications of piezoresistive sensors: A review
Fiorillo, A. S., Critello, C. D., & Pullano, S. A. (2018) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2018.07.006 · Cited by 591
Wearable piezoresistive pressure sensors based on 3D graphene
Cao, M., Su, J., Fan, S., Qiu, H., Su, D., & Li, L. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126777 · Cited by 373
Ding, Y., Xu, T., Onyilagha, O., Fong, H., & Zhu, Z. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b20929 · Cited by 366
Graphene Nanoplatelets-Based Advanced Materials and Recent Progress in Sustainable Applications
Cataldi, P., Athanassiou, A., & Bayer, I. S. (2018) · Applied Sciences · doi:10.3390/app8091438 · Cited by 352
Metadata
- Authors
- Rinaldi, A., Tamburrano, A., Fortunato, M., & Sarto, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-12-16
- Volume
- 16
- Issue
- 12
- Pages
- 2148
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2566997854
- Cited by
- 194
- References
- 4
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.