The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index, and 1 are not checked yet.
Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection
Open accessAbstract
Long-term electrocardiogram (ECG) monitoring, as a representative application of cyber-physical systems, facilitates the early detection of arrhythmia. A considerable number of previous studies has explored monitoring techniques and the automated analysis of sensing data. However, ensuring patient privacy or confidentiality has not been a primary concern in ECG monitoring. First, we propose an intelligent heart monitoring system, which involves a patient-worn ECG sensor (e.g., a smartphone) and a remote monitoring station, as well as a decision support server that interconnects these components. The decision support server analyzes the heart activity, using the Pan–Tompkins algorithm to detect heartbeats and a decision tree to classify them. Our system protects sensing data and user privacy, which is an essential attribute of dependability, by adopting signal scrambling and anonymous identity schemes. We also employ a public key cryptosystem to enable secure communication between the entities. Simulations using data from the MIT-BIH arrhythmia database demonstrate that our system achieves a 95.74% success rate in heartbeat detection and almost a 96.63% accuracy in heartbeat classification, while successfully preserving privacy and securing communications among the involved entities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quinlan, J. R. (1986) · Machine Learning · doi:10.1007/bf00116251 · Cited by 21,439
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812 · cited 2×
“To evaluate our classifier in terms of accuracy, we used the MIT-BIH arrhythmia database [14], which contains 48 30-minute excerpts of two-channel ambulatory ECG recordings, obtained from 47 patients studied at the BIH Arrhythmia Laboratory between 1975 and 1979.”
MethodAuthors/Task Force Members, Van de Werf, F., Bax, J., Betriu, A., Blomstrom-Lundqvist, C., Crea, F., Falk, V., Filippatos, G., Fox, K., Huber, K., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn416 · Cited by 2,310 · cited 1×
“The position and distance of the PR interval and segment, the ST interval and segment and the QT interval and QRS complex can be used in a diagnosis [3].”
MethodGoldreich, O. (2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511546891 · Cited by 2,181
Goldreich, O. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511721656 · Cited by 1,805
Weaknesses in the Key Scheduling Algorithm of RC4
Fluhrer, S., Mantin, I., & Shamir, A. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45537-x_1 · Cited by 1,043 · cited 1×
“However, RC4 is known to be insecure, owing to a weakness of the key scheduling algorithm [38].”
BackgroundProbabilistic encryption & how to play mental poker keeping secret all partial information
Goldwasser, S., & Micali, S. (1982) · Proceedings of the fourteenth annual ACM symposium on Theory of computing - STOC '82 · doi:10.1145/800070.802212 · Cited by 883 · cited 1×
“To transfer the sensing signal securely, we use a stream cipher that consists of a pseudo-random generator (PRG) and a bitwise exclusive OR operator [32].”
MethodAnonymity, Unobservability, and Pseudonymity — A Proposal for Terminology
Pfitzmann, A., & Köhntopp, M. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-44702-4_1 · Cited by 763
Research works printed but not linked: 4
- Mitchell, T. (1997). Machine Learning, McGraw-Hill Inc.. MCGraw-Hill International Editions.
- Witten, I., and Frank, E. (2005). Practical Machine Learning Tools and Techniques, Morgan Kaufmann.
- Rao, J., and Rohatgi, P. (2000, January 14–17). Can pseudonyms really guarantee privacy?. Proceedings of the 9th USENIX Security Symposium, Denver, CO, USA.
- Prakash, 2005, How to tell heart rate from an ECG?, Am. Physiol. Soc., 29, 57
Cited by
Secure, privacy-preserving and federated machine learning in medical imaging
Kaissis, G. A., Makowski, M. R., Rückert, D., & Braren, R. F. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-0186-1 · Cited by 1,676
Internet of Medical Things (IoMT) - An overview
Vishnu, S., Ramson, S. R. J., & Jegan, R. (2020) · 2020 5th International Conference on Devices, Circuits and Systems (ICDCS) · doi:10.1109/icdcs48716.2020.243558 · Cited by 283
PrivacyProtector: Privacy-Protected Patient Data Collection in IoT-Based Healthcare Systems
Luo, E., Bhuiyan, M. Z. A., Wang, G., Rahman, M. A., Wu, J., & Atiquzzaman, M. (2018) · IEEE Communications Magazine · doi:10.1109/mcom.2018.1700364 · Cited by 266
“[9] J.”
MethodSelf-citationEvolution, Current Challenges, and Future Possibilities in ECG Biometrics
Ribeiro Pinto, J., Cardoso, J. S., & Lourenco, A. (2018) · IEEE Access · doi:10.1109/access.2018.2849870 · Cited by 195
“[159] proposed a signal scrambling method to secure transmitted data and anonymous identity schemes to preserve privacy in an intelligent arrhythmia detection system.”
MethodKhan, A., Ali, I., Ghani, A. K., Khan, N., Alsaqer, M., Rahman, A. U., & Mahmood, H. (2018) · Sensors · doi:10.3390/s18051619 · Cited by 142
Metadata
- Authors
- Son, J., Park, J., Oh, H., Bhuiyan, M., Hur, J., & Kang, K.
- Affiliations
- Kennesaw State University (US)
- Korea Expressway Corporation (South Korea) (KR)
- Hanyang University (KR)
- Fordham University (US)
- Korea University (KR)
- Corresponding author
- Hur, Junbeom
- Kang, Kyungtae
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-06-12
- Volume
- 17
- Issue
- 6
- Pages
- 1360
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC5492002
- OpenAlex
- W2624346713
- Cited by
- 25
- References
- 34
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 3 · 2022: 5 · 2021: 3 · 2020: 2 · 2019: 1 · 2018: 6 · 2017: 2
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministry of Science, ICT and Future Planning (MSIP), Korea, under the ITRC (Information Technology Research Center) (IITP-2017-2014-0-00636)
- ITP grant funded by the Korean government (MSIP) (2014-0-00065, 2017-0-00395)
- NRF (National Research Foundation of Korea) grant funded by the Korean government (MEST) (NRF-2015R1D1A1A09058200)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- ECG monitoring, arrhythmia detection, patient privacy, wearable ECG sensors, smartphone-based monitoring, remote patient monitoring, heartbeat detection, Pan-Tompkins algorithm, heartbeat classification, signal scrambling, anonymous identity, public-key cryptography, secure communication, MIT-BIH arrhythmia database
- MeSH terms
- Algorithms, Arrhythmias, Cardiac, Electrocardiography, Heart Rate, Humans, Signal Processing, Computer-Assisted, Privacy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection. https://app.cochat.ai/papers/10.3390/s17061360
- The paper
- Son, J., Park, J., Oh, H., Bhuiyan, M., Hur, J., & Kang, K. (2017). Privacy-Preserving Electrocardiogram Monitoring for Intelligent Arrhythmia Detection. Sensors. https://doi.org/10.3390/s17061360
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.