Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Indoor fire detection using gas chemical sensing has been a subject of investigation since the early nineties. This approach leverages the fact that, for certain types of fire, chemical volatiles appear before smoke particles do. Hence, systems based on chemical sensing can provide faster fire alarm responses than conventional smoke-based fire detectors. Moreover, since it is known that most casualties in fires are produced from toxic emissions rather than actual burns, gas-based fire detection could provide an additional level of safety to building occupants. In this line, since the 2000s, electrochemical cells for carbon monoxide sensing have been incorporated into fire detectors. Even systems relying exclusively on gas sensors have been explored as fire detectors. However, gas sensors respond to a large variety of volatiles beyond combustion products. As a result, chemical-based fire detectors require multivariate data processing techniques to ensure high sensitivity to fires and false alarm immunity. In this paper, we the survey toxic emissions produced in fires and defined standards for fire detection systems. We also review the state of the art of chemical sensor systems for fire detection and the associated signal and data processing algorithms. We also examine the experimental protocols used for the validation of the different approaches, as the complexity of the test measurements also impacts on reported sensitivity and specificity measures. All in all, further research and extensive test under different fire and nuisance scenarios are still required before gas-based fire detectors penetrate largely into the market. Nevertheless, the use of dynamic features and multivariate models that exploit sensor correlations seems imperative.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Logistic regression and Artificial Neural Network Classification models: A methodology review
Dreiseitl, S., & Ohno-Machado, L. (2002) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00034-0 · Cited by 2,177 · cited 2×
“However, other classification algorithms that usually show lower generalization error [68] have also been explored for reliable fire detection.”
BackgroundMetal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring
Fine, G. F., Cavanagh, L. M., Afonja, A., & Binions, R. (2010) · Sensors · doi:10.3390/s100605469 · Cited by 1,477
Amperometric Gas SensorsA Review
Stetter, J. R., & Li, J. (2008) · Chemical Reviews · doi:10.1021/cr0681039 · Cited by 485 · cited 1×
“We refer interested readers in the principle of operation of electrochemical cells to already published reviews [58,59].”
BackgroundCoburn, R. F., Forster, R. E., & Kane, P. B. (1965) · Journal of Clinical Investigation · doi:10.1172/jci105296 · Cited by 433 · cited 1×
“The Coburn-Forster-Kane (CFK) equation describes the dynamics of COHb formation from CO inhalation [25].”
TiO2 Nanotubes: Recent Advances in Synthesis and Gas Sensing Properties
Galstyan, V., Comini, E., Faglia, G., & Sberveglieri, G. (2013) · Sensors · doi:10.3390/s131114813 · Cited by 194
Pitts, W. M. (1995) · Progress in Energy and Combustion Science · doi:10.1016/0360-1285(95)00004-2 · Cited by 158 · cited 1×
“The emission of CO is related to the air-fuel ratio (equivalence ratio) [17]:”
BackgroundFire toxicity – The elephant in the room?
Stec, A. A. (2017) · Fire Safety Journal · doi:10.1016/j.firesaf.2017.05.003 · Cited by 126
Paabo, M., & Levin, B. C. (1987) · Fire and Materials · doi:10.1002/fam.810110203 · Cited by 81 · cited 1×
“Acrolein can be emitted, among other materials, from polyethylenes [24].”
BackgroundMulti-criteria fire detection systems using a probabilistic neural network
Rose‐Pehrsson, S. L., Shaffer, R. E., Hart, S. J., Williams, F. W., Gottuk, D. T., Strehlen, B. D., & Hill, S. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00481-0 · Cited by 71
Fire smoke toxicity: The effect of nitrogen oxides
Paul, K. T., Hull, T. R., Lebek, K., & Stec, A. A. (2008) · Fire Safety Journal · doi:10.1016/j.firesaf.2007.10.003 · Cited by 58
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Sensors for daily life: A review
Javaid, M., Haleem, A., Rab, S., Pratap Singh, R., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100121 · Cited by 430
Metadata
- Authors
- Fonollosa, J., Solórzano, A., & Marco, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-02-11
- Volume
- 18
- Issue
- 2
- Pages
- 553
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2792580111
- Cited by
- 189
- References
- 14
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.