CoChat

Hydrogel-Based Fluorescent Dual pH and Oxygen Sensors Loaded in 96-Well Plates for High-Throughput Cell Metabolism Studies

Wu, Shanshan, Wu, Siying, Yi, Zheyuan, Zeng, Fei, Wu, Weizhen, Qiao, Yuan, Zhao, Xingzhong, Cheng, Xing, Tian, Yanqing · 2018 · Sensors
Cited by 41

The DOI matches its Crossref record.

Abstract

In this study, we developed fluorescent dual pH and oxygen sensors loaded in multi-well plates for in-situ and high-throughput monitoring of oxygen respiration and extracellular acidification during microbial cell growth for understanding metabolism. Biocompatible PHEMA-co-PAM materials were used as the hydrogel matrix. A polymerizable oxygen probe (OS2) derived from PtTFPP and a polymerizable pH probe (S2) derived from fluorescein were chemically conjugated into the matrix to solve the problem of the probe leaching from the matrix. Gels were allowed to cure directly on the bottom of 96-well plates at room-temperature via redox polymerization. The influence of matrix’s composition on the sensing behaviors was investigated to optimize hydrogels with enough robustness for repeatable use with good sensitivity. Responses of the dual sensing hydrogels to dissolved oxygen (DO) and pH were studied. These dual oxygen-pH sensing plates were successfully used for microbial cell-based screening assays, which are based on the measurement of fluorescence intensity changes induced by cellular oxygen consumption and pH changes during microbial growth. This method may provide a real-time monitoring of cellular respiration, acidification, and a rapid kinetic assessment of multiple samples for cell viability as well as high-throughput drug screening. All of these assays can be carried out by a conventional plate reader.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s18020564

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 36

  1. Beal, 1993, Do defecs in mitochondrial energy metabolism underlie the pathology of neurodegenerative diseases?, Trends Neurosci., 16, 125, 10.1016/0166-2236(93)90117-5 · DOI · Paper page
  2. Rosas, 1999, The effect of dissolved oxygen and salinity on oxygen consumption, ammonia excretion and osmotic pressure of Penaeus setiferus (Linnaeus) juveniles, J. Exp. Mar. Biol. Ecol., 234, 41, 10.1016/S0022-0981(98)00139-7 · DOI
  3. Morrison, 2000, Culture in reduced levels of oxygen promotes clonogenic sympathoadrenal differentiation by isolated neural crest stem cells, J. Neurosci., 20, 7370, 10.1523/JNEUROSCI.20-19-07370.2000 · DOI · Paper page
  4. Amon, 1996, Photochemical and microbial consumption of dissolved organic carbon and dissolved oxygen in the Amazon River system, Geochim. Cosmochim. Acta, 60, 1783, 10.1016/0016-7037(96)00055-5 · DOI · Paper page
  5. Bandyopadhyay, 1999, Reactive oxygen species: Oxidative damage and pathogenesis, Curr. Sci., 77, 658
  6. Apel, 2004, Reactive oxygen species: Metabolism, oxidative stress, and signal transduction, Annu. Rev. Plant Biol., 55, 373, 10.1146/annurev.arplant.55.031903.141701 · DOI · Paper page
  7. Su, 2011, Catechol polymers for pH-responsive, targeted drug delivery to cancer cells, J. Am. Chem. Soc., 133, 11850, 10.1021/ja203077x · DOI · Paper page
  8. Hansen, 2016, Influence of extracellular pH on growth, viability, cell size, acidification activity, and intracellular pH of lactococcus lactis in batch fermentations, Appl. Microbiol. Biotechnol., 100, 5965, 10.1007/s00253-016-7454-3 · DOI
  9. Hainaut, 2013, Targeting the hallmarks of cancer: Towards a rational approach to next-generation cancer therapy, Curr. Opin. Oncol., 25, 50, 10.1097/CCO.0b013e32835b651e · DOI · Paper page
  10. Hanahan, 2011, Hallmarks of cancer: The next generation, Cell, 144, 646, 10.1016/j.cell.2011.02.013 · DOI · Paper page
  11. Wang, 2014, Optical methods for sensing and imaging oxygen: Materials, spectroscopies and applications, Chem. Soc. Rev., 43, 3666, 10.1039/C4CS00039K · DOI · Paper page
  12. Wolfbeis, 2005, Materials for fluorescence-based optical chemical sensors, J. Mater. Chem., 15, 2657, 10.1039/b501536g · DOI · Paper page
  13. Wolfbeis, 2000, Fiber-optic chemical sensors and biosensors, Anal. Chem., 72, 81, 10.1021/a1000013k · DOI · Paper page
  14. Zou, 2017, Luminescence materials for pH and oxygen sensing in microbial cells-structures, optical properties, and biological applications, Crit. Rev. Biotechnol., 37, 723, 10.1080/07388551.2016.1223011 · DOI
  15. Nagl, 2007, Optical multiple chemical sensing: Status and current challenges, Analyst, 132, 507, 10.1039/b702753b · doi:10.1039/b702753b
  16. Vasylevska, 2006, Indicator-loaded permeation-selective microbeads for use in fiber optic simultaneous sensing of pH and dissolved oxygen, Chem. Mater., 18, 4609, 10.1021/cm060967n · DOI
  17. Polerecky, 2007, Time-resolved pH/pO2 mapping with luminescent hybrid sensors, Anal. Chem., 79, 60, 10.1021/ac0606047 · DOI
  18. Nagl, 2008, Multiplex bacterial growth monitoring in 24-well microplates using a dual optical sensor for dissolved oxygen and pH, Biotechnol. Bioeng., 100, 430, 10.1002/bit.21793 · DOI
  19. Lu, 2011, New ratiometric optical oxygen and pH dual sensors with three emission colors for measuring photosynthetic activity in cyanobacteria, J. Mater. Chem., 21, 19293, 10.1039/c1jm13754a · DOI
  20. Wang, 2012, Ultra-small, highly stable, and sensitive dual nanosensors for imaging intracellular oxygen and pH in cytosol, J. Am. Chem. Soc., 134, 17011, 10.1021/ja308830e · DOI · Paper page
  21. Meier, 2011, Simultaneous photographing of oxygen and pH in vivo using sensor films, Angew. Chem. Int. Ed., 50, 10893, 10.1002/anie.201104530 · DOI
  22. Zhou, X.F., Su, F.Y., Tian, Y.Q., and Meldrum, D.R. (2014). Dually fluorescent core-shell microgels for ratiometric imaging in live antigen-presenting cells. PLoS ONE, 9. · DOI
  23. Borchert, 2011, O2/pH multisensor based on one phosphorescent dye, Anal. Chem., 83, 18, 10.1021/ac1025754 · doi:10.1021/ac1025754
  24. Wang, 2013, Fluorescent pH-sensitive nanoparticles in an agarose matrix for imaging of bacterial growth and metabolism, Angew. Chem. Int. Ed., 52, 406, 10.1002/anie.201205715 · DOI
  25. Birmele, 2006, Characterization of methods for determining sterilization efficacy and reuse efficiency of oxygen biosensor multiwell plates, J. Microbiol. Meth., 67, 619, 10.1016/j.mimet.2006.06.003 · doi:10.1016/j.mimet.2006.06.003
  26. Chen, 2002, Characterization of ormosil film for dissolved oxygen-sensing, Sens. Actuators B Chem., 87, 233, 10.1016/S0925-4005(02)00241-1 · DOI
  27. Strobl, 2016, Design and application of an optical sensor for simultaneous imaging of pH and dissolved O2 with low cross-talk, ACS Sens., 1, 681, 10.1021/acssensors.6b00071 · doi:10.1021/acssensors.6b00071
  28. Tian, 2010, A series of naphthalimide derivatives as intra and extracellular pH sensors, Biomaterials, 31, 7411, 10.1016/j.biomaterials.2010.06.023 · DOI
  29. Tian, 2010, Influence of matrices on oxygen sensing of three sensing films with chemically conjugated platinum porphyrin probes and preliminary application for monitoring of oxygen consumption of Escherichia coli (E. coli), Sens. Actuators B Chem., 150, 579, 10.1016/j.snb.2010.08.036 · DOI · Paper page
  30. Tian, 2010, A new cross-linkable oxygen sensor covalently bonded into poly(2-hydroxyethyl methacrylate)-co-polyacrylamide thin film for dissolved oxygen sensing, Chem. Mater., 22, 2069, 10.1021/cm903361y · doi:10.1021/cm903361y
  31. Tian, 2010, Dually fluorescent sensing of pH and dissolved oxygen using a membrane made from polymerizable sensing monomers, Sens. Actuators B Chem., 147, 714, 10.1016/j.snb.2010.03.029 · doi:10.1016/j.snb.2010.03.029
  32. Sarac, 1999, Redox polymerization, Prog. Polym. Sci., 24, 1149, 10.1016/S0079-6700(99)00026-X · DOI · Paper page
  33. Fornasiero, 2005, Steady-state diffusion of water through soft-contact-lens materials, Biomaterials, 26, 5704, 10.1016/j.biomaterials.2005.02.028 · doi:10.1016/j.biomaterials.2005.02.028
  34. Wang, 2008, Influence of water states in hydrogels on the transmissibility and permeability of oxygen in contact lens materials, Appl. Surf. Sci., 255, 604, 10.1016/j.apsusc.2008.06.178 · DOI
  35. Buckley, 2000, A cell viability assay based on monitoring respiration by optical oxygen sensing, Anal. Biochem., 278, 221, 10.1006/abio.1999.4431 · DOI
  36. West, 1974, Proton/sodium ion antiport in Escherichia coli, Biochem. J., 144, 87, 10.1042/bj1440087 · DOI · Paper page

Cited by

See all 41

Metadata

Authors
Wu, S., Wu, S., Yi, Z., Zeng, F., Wu, W., Qiao, Y., Zhao, X., Cheng, X., & Tian, Y.
Venue
Sensors
Publisher
MDPI AG
Published
2018-02-13
Volume
18
Issue
2
Pages
564
ISSN
1424-8220
Cited by
41
References
0
Language
en
Funders
  • National Science Foundation of China (21574061 and 21604036)
  • Shenzhen fundamental research programs (JCYJ20150630145302243)
  • start fund of SUSTech (FRG-SUSTC1501A-01, Y01256009)
  • Shenzhen Science and Technology Innovation Committee for key laboratory (ZDSYS20140509142721431)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydrogel-Based Fluorescent Dual pH and Oxygen Sensors Loaded in 96-Well Plates for High-Throughput Cell Metabolism Studies. https://app.cochat.ai/papers/10.3390/s18020564
The paper
Wu, S., Wu, S., Yi, Z., Zeng, F., Wu, W., Qiao, Y., Zhao, X., Cheng, X., & Tian, Y. (2018). Hydrogel-Based Fluorescent Dual pH and Oxygen Sensors Loaded in 96-Well Plates for High-Throughput Cell Metabolism Studies. Sensors. https://doi.org/10.3390/s18020564

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.