The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Wearable Hardware Design for the Internet of Medical Things (IoMT)
Open accessAbstract
As the life expectancy of individuals increases with recent advancements in medicine and quality of living, it is important to monitor the health of patients and healthy individuals on a daily basis. This is not possible with the current health care system in North America, and thus there is a need for wireless devices that can be used from home. These devices are called biomedical wearables, and they have become popular in the last decade. There are several reasons for that, but the main ones are: expensive health care, longer wait times, and an increase in public awareness about improving quality of life. With this, it is vital for anyone working on wearables to have an overall understanding of how they function, how they were designed, their significance, and what factors were considered when the hardware was designed. Therefore, this study attempts to investigate the hardware components that are required to design wearable devices that are used in the emerging context of the Internet of Medical Things (IoMT). This means that they can be used, to an extent, for disease monitoring through biosignal capture. In particular, this review study covers the basic components that are required for the front-end of any biomedical wearable, and the limitations that these wearable devices have. Furthermore, there is a discussion of the opportunities that they create, and the direction that the wearable industry is heading in.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Edge computing: Vision and challenges
Shi, W., Cao, J., Zhang, Q., Li, Y., & Xu, L. (2016) · IEEE Internet of Things Journal · doi:10.1109/jiot.2016.2579198 · Cited by 8,733
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Tavakoli, M., Benussi, C., Alhais Lopes, P., Osorio, L. B., & de Almeida, A. T. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.07.010 · Cited by 173
Wei, J. (2014) · IEEE Consumer Electronics Magazine · doi:10.1109/mce.2014.2317895 · Cited by 154 · cited 6×
“Furthermore, wearable devices are defined as devices that can be worn by an individual and can continuously monitor an individual’s activity without interruption [3,4].”
BackgroundInfluential
Cited by
The Internet of Things (IoT) in healthcare: Taking stock and moving forward
Rejeb, A., Rejeb, K., Treiblmaier, H., Appolloni, A., Alghamdi, S., Alhasawi, Y., & Iranmanesh, M. (2023) · Internet of Things · doi:10.1016/j.iot.2023.100721 · Cited by 448
Flexible Energy Storage Devices to Power the Future
He, J., Cao, L., Cui, J., Fu, G., Jiang, R., Xu, X., & Guan, C. (2024) · Advanced Materials · doi:10.1002/adma.202306090 · Cited by 286
Kumar, R., & Tripathi, R. (2021) · The Journal of Supercomputing · doi:10.1007/s11227-020-03570-x · Cited by 177
Metadata
- Authors
- Qureshi, F., & Krishnan, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-11-07
- Volume
- 18
- Issue
- 11
- Pages
- 3812
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2900009200
- Cited by
- 158
- References
- 4
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Hardware Design for the Internet of Medical Things (IoMT). https://app.cochat.ai/papers/10.3390/s18113812
- The paper
- Qureshi, F., & Krishnan, S. (2018). Wearable Hardware Design for the Internet of Medical Things (IoMT). Sensors. https://doi.org/10.3390/s18113812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.