Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 68

The DOI matches its Crossref record.

Wearable Hand Module and Real-Time Tracking Algorithms for Measuring Finger Joint Angles of Different Hand Sizes with High Accuracy Using FBG Strain Sensor

Kim, Jun, Kim, Byung, Jang, Minsu, Kang, Kyumin, Kim, Dae, Ju, Byeong-Kwon, Kim, Jinseok · 2020 · Sensors

Abstract

This paper presents a wearable hand module which was made of five fiber Bragg grating (FBG) strain sensor and algorithms to achieve high accuracy even when worn on different hand sizes of users. For real-time calculation with high accuracy, FBG strain sensors move continuously according to the size of the hand and the bending of the joint. Representatively, four algorithms were proposed; point strain (PTS), area summation (AREA), proportional summation (PS), and PS/interference (PS/I or PS/I_ α ). For more accurate and efficient assessments, 3D printed hand replica with different finger sizes was adopted and quantitative evaluations were performed for index~little fingers (77 to 117 mm) and thumb (68~78 mm). For index~little fingers, the optimized algorithms were PS and PS/I_ α . For thumb, the optimized algorithms were PS/I_ α and AREA. The average error angle of the wearable hand module was observed to be 0.47 ± 2.51° and mean absolute error (MAE) was achieved at 1.63 ± 1.97°. These results showed that more accurate hand modules than other glove modules applied to different hand sizes can be manufactured using FBG strain sensors which move continuously and algorithms for tracking this movable FBG sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20071921

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 41

  1. Nishiyama, 2009, Wearable sensing glove with embedded hetero-core fiber-optic nerves for unconstrained hand motion capture, IEEE Trans. Instrum. Meas., 58, 3995, 10.1109/TIM.2009.2021640 · doi:10.1109/tim.2009.2021640
  2. Cui, J., and Sun, Z. (2004, January 19). Visual hand motion capture for guiding a dexterous hand. Proceedings of the 2004 6th IEEE International Conference on Automatic Face and Gesture Recognition, Seoul, Korea.
  3. Li, 2015, Flexible CNT-array double helices strain sensor with high stretchability for motion capture, Sci. Rep., 5, 1
  4. Ma, 2010, Magnetic hand motion tracking system for human–machine interaction, Electron. Lett., 46, 621, 10.1049/el.2010.0220 · doi:10.1049/el.2010.0220
  5. Kim, D., Yoon, S., Park, Y., Jeon, K., Park, S., Jeon, J., and Seo, K. (2014, January 17–19). Design and Implementation of a Wearable Hand Rehabilitation Robot for spasticity patient. Proceedings of the 2014 Korean Society of Computer Information Conference, Jeju, Korea.
  6. Jha, 2019, An FBG-based sensing glove to measure dynamic finger flexure with an angular resolution of 0.1 up to speeds of 80/s, J. Lightwave Technol., 37, 4734, 10.1109/JLT.2019.2919496 · doi:10.1109/jlt.2019.2919496
  7. Park, W., Ro, K., Kim, S., and Bae, J. (2017). A soft sensor-based three-dimensional (3-D) finger motion measurement system. Sensors, 17. · DOI
  8. Sani, M.F., Abeywardena, S., Psomopoulou, E., Ascione, R., and Dogramadzi, S. (2019, January 26–28). Towards Finger Motion Tracking and Analyses for Cardiac Surgery. Proceedings of the 15th Mediterranean Conference on Medical and Biological Engineering and Computing (MEDICON 2019), Coimbra, Porutugal.
  9. Wang, L., Meydan, T., and Williams, P.I. (2017). A two-axis goniometric sensor for tracking finger motion. Sensors, 17. · DOI
  10. Gumpp, T., Azad, P., Welke, K., Oztop, E., Dillmann, R., and Cheng, G. (2006, January 4–6). Unconstrained Real-time Markerless Hand Tracking for Humanoid Interaction. Proceedings of the 6th IEEE-RAS International Conference on Humanoid Robots, Genova, Italy. · DOI
  11. Ballan, L., and Cortelazzo, G.M. (2008, January 18–20). Marker-less motion capture of skinned models in a four camera set-up using optical flow and silhouettes. Proceedings of the 3DPVT, Atlanta, GA, USA.
  12. Shimada, N., Shirai, Y., Kuno, Y., and Miura, J. (1998, January 14–16). Hand gesture estimation and model refinement using monocular camera-ambiguity limitation by inequality constraints. Proceedings of the IEEE International Conference on Automatic Face and Gesture Recognition, Nara, Japan.
  13. Erol, 2007, Vision-based hand pose estimation: A review, Comput. Vis. Image Underst., 108, 52, 10.1016/j.cviu.2006.10.012 · DOI · Paper page
  14. Ahmad, 2013, Reviews on various inertial measurement unit (IMU) sensor applications, Int. J. Signal Proc., 1, 256
  15. Esser, 2009, IMU: Inertial sensing of vertical CoM movement, J. Biomech., 42, 1578, 10.1016/j.jbiomech.2009.03.049 · DOI
  16. Bai, S., Lai, J., Lyu, P., Xu, X., Liu, M., and Huang, K. (2019). A System-Level Self-Calibration Method for Installation Errors in A Dual-Axis Rotational Inertial Navigation System. Sensors, 19. · doi:10.3390/s19184005
  17. Narasimhappa, 2019, MEMS Based IMU Drift Minimization: Sage Husa Adaptive Robust Kalman Filtering, IEEE Sens. J., 20, 250, 10.1109/JSEN.2019.2941273 · DOI
  18. Wittmann, F., Lambercy, O., and Gassert, R. (2019). Magnetometer-based drift correction during rest in IMU arm motion tracking. Sensors, 19. · doi:10.3390/s19061312
  19. Bravo-Illanes, G.P., Halvorson, R., Matthew, R., Lansdown, D., Ma, C., and Bajcsy, R. (2019, January 23–27). IMU Sensor Fusion Algorithm for Monitoring Knee Kinematics in ACL Reconstructed Patients. Proceedings of the 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany. · DOI
  20. Li, M.P., Zhuo, Y., He, B., Liang, Z., Xu, G., Xie, J., and Zhang, S. (2019, January 24–27). A 3D-printed soft hand exoskeleton with finger abduction assistance. Proceedings of the 16th International Conference on Ubiquitous Robots (UR), Jeju, Korea. · doi:10.1109/urai.2019.8768611
  21. Lu, 2019, A 3-D finger motion measurement system via soft strain sensors for hand rehabilitation, Sens. Actuators A, 285, 700, 10.1016/j.sna.2018.12.004 · DOI
  22. Li, 2018, A wearable detector for simultaneous finger joint motion measurement, IEEE Trans. Biomed. Circuits Syst., 12, 644, 10.1109/TBCAS.2018.2810182 · DOI
  23. Sato, 2019, Ferroelectric polymer-based fully printed flexible strain rate sensors and their application for human motion capture, Sens. Actuators A, 295, 93, 10.1016/j.sna.2019.05.022 · DOI
  24. Borghetti, 2013, Sensorized glove for measuring hand finger flexion for rehabilitation purposes, IEEE Trans. Instrum. Meas., 62, 3308, 10.1109/TIM.2013.2272848 · DOI
  25. Wise, 1990, Evaluation of a fiber optic glove for se-automated goniometric measurements, J. Rehabil. Res. Dev., 27, 411, 10.1682/JRRD.1990.10.0411 · DOI
  26. Najafi, 2003, Ambulatory system for human motion analysis using a kinematic sensor: Monitoring of daily physical activity in the elderly, IEEE Trans. Biomed. Eng., 50, 711, 10.1109/TBME.2003.812189 · DOI · Paper page
  27. Balogun, 1988, Factors affecting Caltrac® and Calcount® accelerometer output, Phys. Ther., 68, 1500
  28. Moreno, 2008, Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions, Physiol. Meas., 29, N21, 10.1088/0967-3334/29/4/N01 · DOI
  29. Gajdosik, 1987, Clinical measurement of range of motion review of goniometry emphasizing reliability and validity, Phys. Ther., 67, 1867, 10.1093/ptj/67.12.1867 · DOI · Paper page
  30. Hill, 1978, Photosensitivity in optical fiber waveguides: Application to reflection filter fabrication, Appl. Phys. Lett., 32, 647, 10.1063/1.89881 · DOI · Paper page
  31. Erdogan, 1997, Fiber grating spectra, J. Lightwave Technol., 15, 1277, 10.1109/50.618322 · DOI · Paper page
  32. Kuang, 2001, Embedded fibre bragg grating sensors in advanced composite materials, Compos. Sci. Technol., 61, 1379, 10.1016/S0266-3538(01)00037-9 · DOI · Paper page
  33. Trutzel, M.N.P., Wauer, K., Betz, D., Staudigel, L., Krumpholz, O., Muehlmann, H.-C., Muellert, T., and Gleine, W. (2000, January 6–9). Smart sensing of aviation structures with fiber optic bragg grating sensors. Proceedings of the Smart Structures and Materials 2000: Sensory Phenomena and Measurement Instrumentation for Smart Structures and Materials, Newport Beach, CA, USA. · doi:10.1117/12.388099
  34. Hopf, 2015, Temperature dependence of glue-induced birefringence in surface-attached FBG strain sensors, J. Lightwave Technol., 34, 1220, 10.1109/JLT.2015.2507621 · doi:10.1109/jlt.2015.2507621
  35. Ramalingam, 2014, Fiber bragg grating sensors for distributed torsional strain measurements in a (RE) BCO tape, IEEE Sens. J., 15, 2023, 10.1109/JSEN.2014.2370671 · doi:10.1109/jsen.2014.2370671
  36. Jin, 2005, An embedded FBG sensor for simultaneous measurement of stress and temperature, IEEE Photonics Technol. Lett., 18, 154, 10.1109/LPT.2005.860046 · DOI
  37. Betz, 2006, Advanced layout of a fiber bragg grating strain gauge rosette, J. Lightwave Technol., 24, 1019, 10.1109/JLT.2005.862442 · doi:10.1109/jlt.2005.862442
  38. Basumallick, 2012, Fiber bragg grating accelerometer with enhanced sensitivity, Sens. Actuators A, 173, 108, 10.1016/j.sna.2011.10.026 · doi:10.1016/j.sna.2011.10.026
  39. He, Y., Zhang, X., Zhu, L., Sun, G., Lou, X., and Dong, M. (2019). Optical Fiber Sensor Performance Evaluation in Soft Polyimide Film with Different Thickness Ratios. Sensors, 19. · DOI
  40. Ge, 2016, Bidirectional Soft Silicone Curvature Sensor Based on Off-Centered Embedded Fiber bragg Grating, IEEE Photonics Technol. Lett., 28, 2237, 10.1109/LPT.2016.2590984 · doi:10.1109/lpt.2016.2590984
  41. Park, Y.P., Lee, J., and Bae, J. (2014, January 8–11). Development of a Finger Motion Measurement System using Linear Potentiometers. Proceedings of the 2014 IEEE/ASME International Conference on Advanced Intelligent Mechatronics, Besacon, France. · doi:10.1109/aim.2014.6878066

Cited by

See all 68

Metadata

Authors
Kim, J., Kim, B., Jang, M., Kang, K., Kim, D., Ju, B.-K., & Kim, J.
Venue
Sensors
Publisher
MDPI AG
Published
2020-03-30
Volume
20
Issue
7
Pages
1921
ISSN
1424-8220
Cited by
68
References
0
Language
en
Funders
  • Korea Institute of Science and Technology Intramural Grant (2E30090)
  • National Research Foundation of Korea (2017M3C1B2085292)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable Hand Module and Real-Time Tracking Algorithms for Measuring Finger Joint Angles of Different Hand Sizes with High Accuracy Using FBG Strain Sensor. https://app.cochat.ai/papers/10.3390/s20071921
The paper
Kim, J., Kim, B., Jang, M., Kang, K., Kim, D., Ju, B.-K., & Kim, J. (2020). Wearable Hand Module and Real-Time Tracking Algorithms for Measuring Finger Joint Angles of Different Hand Sizes with High Accuracy Using FBG Strain Sensor. Sensors. https://doi.org/10.3390/s20071921

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.