The DOI matches its Crossref record; 171 of the 171 references it cites were found in a registry or an index.
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Open accessAbstract
The coupling of waves between the piezoelectric generators, detectors, and propagating media is challenging due to mismatch in the acoustic properties. The mismatch leads to the reverberation of waves within the transducer, heating, low signal-to-noise ratio, and signal distortion. Acoustic impedance matching increases the coupling largely. This article presents standard methods to match the acoustic impedance of the piezoelectric sensors, actuators, and transducers with the surrounding wave propagation media. Acoustic matching methods utilizing active and passive materials have been discussed. Special materials such as nanocomposites, metamaterials, and metasurfaces as emerging materials have been presented. Emphasis is placed throughout the article to differentiate the difference between electric and acoustic impedance matching and the relation between the two. Comparison of various techniques is made with the discussion on capabilities, advantages, and disadvantages. Acoustic impedance matching for specific and uncommon applications has also been covered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Locally Resonant Sonic Materials
Liu, Z., Zhang, X., Mao, Y., Zhu, Y. Y., Yang, Z., Chan, C. T., & Sheng, P. (2000) · Science · doi:10.1126/science.289.5485.1734 · Cited by 5,464
Ultrahigh strain and piezoelectric behavior in relaxor based ferroelectric single crystals
Park, S.-E., & Shrout, T. R. (1997) · Journal of Applied Physics · doi:10.1063/1.365983 · Cited by 4,157
Ferroelectric Ceramics: History and Technology
Haertling, G. H. (1999) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1999.tb01840.x · Cited by 4,051
Durnin, J., Miceli, J. J., & Eberly, J. H. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.1499 · Cited by 3,667
Recent advances in ZnO materials and devices
Look, D. C. (2001) · Materials Science and Engineering: B · doi:10.1016/s0921-5107(00)00604-8 · Cited by 2,831
A review of power harvesting using piezoelectric materials (2003–2006)
Anton, S. R., & Sodano, H. A. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/3/r01 · Cited by 2,652
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493
Observation of Accelerating Airy Beams
Siviloglou, G. A., Broky, J., Dogariu, A., & Christodoulides, D. N. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.213901 · Cited by 2,411
Controlling sound with acoustic metamaterials
Cummer, S. A., Christensen, J., & Alù, A. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.1 · Cited by 2,170
Nye, J. F., & Berry, M. V. (1974) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1974.0012 · Cited by 2,157
Research works printed but not linked: 302
- Win, K.K., Wang, J., Zhang, C., and Yang, R. (2010, January 15–17). Identification and Removal of Reverberation in Ultrasound Imaging. Proceedings of the 2010 5th IEEE Conference on Industrial Electronics and Applications, Taichung, Taiwan. · doi:10.1109/iciea.2010.5515209
- Scanlan, 1991, Sonographic artifacts and their origins, Am. J. Roentgenol., 156, 1267, 10.2214/ajr.156.6.2028876 · doi:10.2214/ajr.156.6.2028876
- Gibson, 2001, A computerised quality control testing system for B-mode ultrasound, Ultrasound Med. Biol., 27, 1697, 10.1016/S0301-5629(01)00479-3 · doi:10.1016/s0301-5629(01)00479-3
- Sunar, 1999, Recent advances in sensing and control of flexible structures via piezoelectric materials technology, Appl. Mech. Rev., 52, 1, 10.1115/1.3098923 · doi:10.1115/1.3098923
- Bent, A.A., and Pizzochero, A.E. (2000, January 12). Recent Advances in Active Fiber Composites for Structural Control. Proceedings of the Smart Structures and Materials 2000: Industrial and Commercial Applications of Smart Structures Technologies, Newport Beach, CA, USA. · doi:10.1117/12.388184
- Moheimani, 2003, A survey of recent innovations in vibration damping and control using shunted piezoelectric transducers, IEEE Trans. Control Syst. Technol., 11, 482, 10.1109/TCST.2003.813371 · doi:10.1109/tcst.2003.813371
- Jain, 2013, Sensitivity of polyvinylidene fluoride films to mechanical vibration modes and impact after optimizing stretching conditions, Polym. Eng. Sci., 53, 707, 10.1002/pen.23318 · doi:10.1002/pen.23318
- Rathod, 2010, Characterization of a large-area PVDF thin film for electro-mechanical and ultrasonic sensing applications, Sensors Actuators A Phys., 163, 164, 10.1016/j.sna.2010.08.017 · doi:10.1016/j.sna.2010.08.017
- Chakraborty, 2012, Guided wave based detection of damage in honeycomb core sandwich structures, NDT E Int., 49, 27, 10.1016/j.ndteint.2012.03.008 · doi:10.1016/j.ndteint.2012.03.008
- Rathod, 2011, Ultrasonic Lamb wave based monitoring of corrosion type of damage in plate using a circular array of piezoelectric transducers, NDT E Int., 44, 628, 10.1016/j.ndteint.2011.07.002 · doi:10.1016/j.ndteint.2011.07.002
- Giridhara, 2010, Rapid localization of damage using a circular sensor array and Lamb wave based triangulation, Mech. Syst. Signal Process., 24, 2929, 10.1016/j.ymssp.2010.06.002 · doi:10.1016/j.ymssp.2010.06.002
- Gruverman, 2006, Piezoresponse force microscopy and recent advances in nanoscale studies of ferroelectrics, J. Mater. Sci., 41, 107, 10.1007/s10853-005-5946-0 · doi:10.1007/s10853-005-5946-0
- Spanner, K., and Vorndran, S. (2003, January 20–24). Advances in Piezo-nanopositioning Technology. Proceedings of the 2003 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM 2003), Kobe, Japan.
- Ekinci, 2005, Electromechanical transducers at the nanoscale: Actuation and sensing of motion in nanoelectromechanical systems (NEMS), Small, 1, 786, 10.1002/smll.200500077 · doi:10.1002/smll.200500077
- Saarimaki, 2006, Novel heat durable electromechanical film: Processing for electromechanical and electret applications, IEEE Trans. Dielectr. Electr. Insul., 13, 963, 10.1109/TDEI.2006.247820 · doi:10.1109/tdei.2006.247820
- Ko, 2010, Use of 2-(6-mercaptohexyl) malonic acid to adjust the morphology and electret properties of cyclic olefin copolymer and its application to flexible loudspeakers, Smart Mater. Struct., 19, 55007, 10.1088/0964-1726/19/5/055007 · doi:10.1088/0964-1726/19/5/055007
- Rathod, V.T., Hiremath, S.R., and Roy Mahapatra, D. (2014, January 10). Strength and Fatigue Life Evaluation of Composite Laminate with Embedded Sensors. Proceedings of the SPIE—The International Society for Optical Engineering, San Diego, CA, USA. · doi:10.1117/12.2047323
- Feng, 2010, Acoustic emission sensor with structure-enhanced sensing mechanism based on micro-embossed piezoelectric polymer, Sensors Actuators A Phys., 162, 100, 10.1016/j.sna.2010.06.019 · doi:10.1016/j.sna.2010.06.019
- Lindahl, 2009, Tactile resonance sensors in medicine, J. Med. Eng. Technol., 33, 263, 10.1080/03091900802491188 · doi:10.1080/03091900802491188
- Jadidian, 2009, 25 MHz ultrasonic transducers with lead- free piezoceramic, 1-3 PZT fiber-epoxy composite, and PVDF polymer active elements, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 56, 368, 10.1109/TUFFC.2009.1046 · doi:10.1109/tuffc.2009.1046
- Bovtun, 2012, Piezoelectric and electrostrictive effects in ferroelectret ultrasonic transducers, J. Appl. Phys., 112, 84505, 10.1063/1.4759052 · doi:10.1063/1.4759052
- Zhou, 2011, Fabrication and performance of endoscopic ultrasound radial arrays based on PMN-PT single crystal/epoxy 1-3 composite, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 58, 477, 10.1109/TUFFC.2011.1825 · DOI
- Liu, C., Djuth, F., Hu, C., Chen, R., Zhang, X., Li, X., Zhou, Q., and Shung, K. (2010, January 11–14). Micromachined High Frequency PMN-PT/Epoxy 1–3 Composite Ultrasonic Annular Arrays. Proceedings of the 2010 IEEE International Ultrasonics Symposium, San Diego, CA, USA. · doi:10.1109/ultsym.2010.5936008
- Rathod, V.T., and Roy Mahapatra, D. (2014, January 10). Ultrasonic Guided Wave Sensing Properties of PVDF Thin Film With Inter Digital Electrodes. Proceedings of the SPIE - The International Society for Optical Engineering, San Diego, CA, USA. · doi:10.1117/12.2047314
- Rathod, V.T., Raju, G., Udpa, L., Udpa, S., and Deng, Y. (2018, January 28–31). Embedded Thin Film Sensors Based Multi-mode Guided Wave Filter. Proceedings of the 2018 IEEE Sensors, New Delhi, India. · doi:10.1109/icsens.2018.8589862
- Rathod, 2020, Multimode guided wave extraction capabilities using embedded thin film sensors in a composite laminated beam, Sensors Actuators A Phys., 309, 112040, 10.1016/j.sna.2020.112040 · doi:10.1016/j.sna.2020.112040
- Dias, 2004, Recent advances in ceramic-polymer composite electrets, IEEE Trans. Dielectr. Electr. Insul., 11, 35, 10.1109/TDEI.2004.1266314 · doi:10.1109/tdei.2004.1266314
- Iannacci, 2019, Microsystem based Energy Harvesting (EH-MEMS): Powering pervasivity of the Internet of Things (IoT)—A review with focus on mechanical vibrations, J. King Saud Univ. Sci., 31, 66, 10.1016/j.jksus.2017.05.019 · doi:10.1016/j.jksus.2017.05.019
- Shung, 1996, Ultrasonic transducers and arrays, IEEE Eng. Med. Biol. Mag., 15, 20, 10.1109/51.544509 · doi:10.1109/51.544509
- Smith, W.A. (1986, January 8–11). Composite Piezoelectric Materials for Medical Ultrasonic Imaging Transducers—A Review. Proceedings of the Sixth IEEE International Symposium on Applications of Ferroelectrics, Bethlehem, PA, USA. · doi:10.1109/isaf.1986.201136
- Callen, P.W. (2011). Ultrasonography in Obstetrics and Gynecology, Elsevier Health Sciences.
- Shung, K.K. (2015). Diagnostic Ultrasound: Imaging and Blood Flow Measurements, CRC Press. · doi:10.1201/b18323
- Lee, 2011, Targeted cell immobilization by ultrasound microbeam, Biotechnol. Bioeng., 108, 1643, 10.1002/bit.23073 · doi:10.1002/bit.23073
- Zhu, 2017, Self-focused AlScN film ultrasound transducer for individual cell manipulation, ACS Sensors, 2, 172, 10.1021/acssensors.6b00713 · doi:10.1021/acssensors.6b00713
- McKeighen, R.E. (1998, January 1). Design guidelines for medical ultrasonic arrays. Proceedings of the SPIE, Medical Imaging 1998: Ultrasonic Transducer Engineering, San Diego, CA, USA.
- Sinclair, 2015, Radiation endurance of piezoelectric ultrasonic transducers—A review, Ultrasonics, 57, 1, 10.1016/j.ultras.2014.10.024 · doi:10.1016/j.ultras.2014.10.024
- Desilets, 1978, The design of efficient broad-band piezoelectric transducers, IEEE Trans. Sonics Ultrason., 25, 115, 10.1109/T-SU.1978.31001 · doi:10.1109/t-su.1978.31001
- Rathod, V.T., and Deng, Y. (2019, January 21). Structural Compatibility of Thin Film Sensors Embedded in a Composite Laminate. Proceedings of the Active and Passive Smart Structures and Integrated Systems XIII, Denver, CO, USA. · doi:10.1117/12.2514393
- Rathod, V.T. (2014). Ultrasonic Guided Wave based Models, Devices and Methods for Integrated Structural Health Monitoring,. [Ph.D. Thesis, Indian Institute of Science].
- Smith, W.A., Shaulov, A.Y., and Auld, B.A. (1985, January 16–18). Tailoring the Properties of Composite Piezoelectric Materials for Medical Ultrasonic Transducers. Proceedings of the IEEE 1985 Ultrasonics Symposium, San Francisco, CA, USA. · doi:10.1109/ultsym.1985.198589
- 1989, Piezoelectric ceramics and ultrasonic transducers, J. Phys. E. Sci. Instrum., 22, 804, 10.1088/0022-3735/22/10/001 · doi:10.1088/0022-3735/22/10/001
- Umeda, K., Kawai, H., Honda, A., Akiyama, M., Kato, T., and Fukura, T. (2013, January 20–24). Piezoelectric properties of ScAlN thin films for piezo-MEMS devices. Proceedings of the 2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS), Taipei, Taiwan. · doi:10.1109/memsys.2013.6474347
- Baklouti, 2001, Binder burnout and evolution of the mechanical strength of dry-pressed ceramics containing poly(vinyl alcohol), J. Eur. Ceram. Soc., 21, 1087, 10.1016/S0955-2219(00)00305-8 · doi:10.1016/s0955-2219(00)00305-8
- Takahiro, 2000, Influence of poling conditions on the piezoelectric properties of PZT ceramics, J. Mater. Sci. Mater. Electron., 11, 425, 10.1023/A:1008975422782 · doi:10.1023/a:1008975422782
- Maeder, 2004, Lead free piezoelectric materials, J. Electroceramics, 13, 385, 10.1007/s10832-004-5130-y · doi:10.1007/s10832-004-5130-y
- Safari, 2010, Lead-free piezoelectric ceramics and thin films, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 57, 2165, 10.1109/TUFFC.2010.1674 · doi:10.1109/tuffc.2010.1674
- Rathod, 2017, Ultrasonic guided wave sensing characteristics of large area thin piezo coating, Smart Mater. Struct., 26, 105009, 10.1088/1361-665X/aa8254 · doi:10.1088/1361-665x/aa8254
- Rathod, V.T., Roy Mahapatra, D., Jeyaseelan, A., and Dutta, S. (2013, January 11). Large-area Piezoceramic Coating with IDT Electrodes for Ultrasonic Sensing Applications. Proceedings of the SPIE, San Diego, CA, USA. · doi:10.1117/12.2011495
- Hsu, 2012, PMN-PT–PZT composite films for high frequency ultrasonic transducer applications, Sensors Actuators A Phys., 179, 121, 10.1016/j.sna.2012.02.031 · doi:10.1016/j.sna.2012.02.031
- Zhenyi, 1994, High field electrostrictive response of polymers, J. Polym. Sci. Part B Polym. Phys., 32, 2721, 10.1002/polb.1994.090321618 · doi:10.1002/polb.1994.090321618
- Ohigashi, 1995, Formation of “single crystalline films” of ferroelectric copolymers of vinylidene fluoride and trifluoroethylene, Appl. Phys. Lett., 66, 3281, 10.1063/1.113730 · doi:10.1063/1.113730
- Lang, 1981, Bibliography on piezoelectricity and pyroelectricity of polymers 1961–1980, Ferroelectrics, 32, 191, 10.1080/00150198108238692 · doi:10.1080/00150198108238692
- Foster, 2000, A history of medical and biological imaging with polyvinylidene fluoride (PVDF) transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 47, 1363, 10.1109/58.883525 · doi:10.1109/58.883525
- Chen, 1995, Industrial applications of piezoelectric polymer transducers, Meas. Sci. Technol., 6, 249, 10.1088/0957-0233/6/3/001 · doi:10.1088/0957-0233/6/3/001
- Bowen, 1996, Design, fabrication, and properties of sonopanelTM 1–3 piezocomposite transducers, Ferroelectrics, 187, 109, 10.1080/00150199608244847 · doi:10.1080/00150199608244847
- Mhalgi, 2007, Stretching induced phase transformations in melt extruded poly(vinylidene fluoride) cast films: Effect of cast roll temperature and speed, Polym. Eng. Sci., 47, 1992, 10.1002/pen.20885 · doi:10.1002/pen.20885
- Ueno, 1999, Effect of crystalline phase, orientation and temperature on the dielectric properties of poly (vinylidene fluoride) (PVDF), J. Mater. Sci., 34, 4489, 10.1023/A:1004689205706 · doi:10.1023/a:1004689205706
- Jayasuriya, 2001, Crystal-structure dependence of electroactive properties in differently prepared poly(vinylidene fluoride/hexafluoropropylene) copolymer films, J. Polym. Sci. Part B Polym. Phys., 39, 2793, 10.1002/polb.10035 · doi:10.1002/polb.10035
- He, 2007, Ferroelectric poly(vinylidene fluoride-hexafluoropropylene) thin films on silicon substrates, Sensors Actuators A Phys., 139, 158, 10.1016/j.sna.2007.02.023 · doi:10.1016/j.sna.2007.02.023
- Vijayakumar, 2010, Studies on α to β phase transformations in mechanically deformed PVDF films, J. Appl. Polym. Sci., 117, 3491, 10.1002/app.32218 · doi:10.1002/app.32218
- 2006, Determination of the α, β, and γ crystalline phases of poly(vinylidene fluoride) films prepared at different conditions, J. Appl. Polym. Sci., 100, 3272, 10.1002/app.23137 · doi:10.1002/app.23137
- Kaura, 1991, Simultaneous stretching and corona poling of PVDF films, J. Phys. D. Appl. Phys., 24, 1848, 10.1088/0022-3727/24/10/020 · doi:10.1088/0022-3727/24/10/020
- Hadji, 2012, Preparation and characterization of P(VDF-TrFE)/Al2O3 nanocomposite, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 59, 163, 10.1109/TUFFC.2012.2168 · doi:10.1109/tuffc.2012.2168
- Harrison, J.S., and Ounaies, Z. (2002). Piezoelectric Polymers. Encyclopedia of Polymer Science and Technology, John Wiley & Sons Inc. · doi:10.1002/0471440264.pst427
- Wang, 1993, Piezoelectric, dielectric, and elastic properties of poly(vinylidene fluoride/trifluoroethylene), J. Appl. Phys., 74, 3394, 10.1063/1.354566 · doi:10.1063/1.354566
- Rathod, V.T., Roy Mahapatra, D., Jain, A., and Gayathri, A. (2012, January 28). Ultrasonic Performance of the PVDF Thin Film Sensors Under Thermal Fatigue. Proceedings of the SPIE, San Diego, CA, USA. · doi:10.1117/12.917603
- Rathod, 2018, Ultrasonic guided wave sensitivity of piezopolymer films subjected to thermal exposure, ISSS J. Micro Smart Syst., 7, 15, 10.1007/s41683-018-0019-1 · doi:10.1007/s41683-018-0019-1
- Klicker, 1981, Composites of PZT and epoxy for hydrostatic transducer applications, J. Am. Ceram. Soc., 64, 5, 10.1111/j.1151-2916.1981.tb09549.x · doi:10.1111/j.1151-2916.1981.tb09549.x
- Safari, 1997, Development of fine-scale piezoelectric composites for transducers, AIChE J., 43, 2849, 10.1002/aic.690431334 · doi:10.1002/aic.690431334
- Chapelon, 2000, New piezoelectric transducers for therapeutic ultrasound, Ultrasound Med. Biol., 26, 153, 10.1016/S0301-5629(99)00120-9 · doi:10.1016/s0301-5629(99)00120-9
- Pilgrim, 1987, An extension of the composite nomenclature scheme, Mater. Res. Bull., 22, 677, 10.1016/0025-5408(87)90117-6 · doi:10.1016/0025-5408(87)90117-6
- Levassort, 1999, Effective electroelastic moduli of 3-3(0-3) piezocomposites, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 46, 1028, 10.1109/58.775670 · doi:10.1109/58.775670
- Newnham, 1986, Composite electroceramics, Ferroelectrics, 68, 1, 10.1080/00150198608238734 · doi:10.1080/00150198608238734
- Halloran, 1999, Freeform fabrication of ceramics, Br. Ceram. Trans., 98, 299, 10.1179/096797899680633 · doi:10.1179/096797899680633
- Smith, W.A. (1989, January 3-6). The role of Piezocomposites in Ultrasonic Transducers. Proceedings of the IEEE Ultrasonics Symposium, Montreal, QC, Canada.
- Akdogan, 2005, Piezoelectric composites for sensor and actuator applications, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 52, 746, 10.1109/TUFFC.2005.1503962 · DOI
- Prashanthi, 2012, A novel photoplastic piezoelectric nanocomposite for MEMS applications, J. Microelectromechanical Syst., 21, 259, 10.1109/JMEMS.2011.2178118 · doi:10.1109/jmems.2011.2178118
- Egusa, 1998, Piezoelectric paints as one approach to smart structural materials with health-monitoring capabilities, Smart Mater. Struct., 7, 438, 10.1088/0964-1726/7/4/002 · doi:10.1088/0964-1726/7/4/002
- Bent, 1997, Piezoelectric fiber composites with interdigitated electrodes, J. Intell. Mater. Syst. Struct., 8, 903, 10.1177/1045389X9700801101 · doi:10.1177/1045389x9700801101
- Lees, 1977, Ultrasonic measurement of some mineral filled plastics, IEEE Trans. Sonics Ultrason., 24, 222, 10.1109/T-SU.1977.30933 · doi:10.1109/t-su.1977.30933
- Sabina, 2001, Overall properties of piezocomposite materials 1–3, Mater. Lett., 48, 93, 10.1016/S0167-577X(00)00285-8 · doi:10.1016/s0167-577x(00)00285-8
- Geng, 1997, Evaluation of piezocomposites for ultrasonic transducer applications influence of the unit cell dimensions and the properties of constituents on the performance of 2-2 piezocomposites, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 44, 857, 10.1109/58.655201 · doi:10.1109/58.655201
- Hossack, 1991, Finite-element analysis of 1-3 composite transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 38, 618, 10.1109/58.108860 · doi:10.1109/58.108860
- Gururaja, 1981, High frequency applications of PZT/polymer composite materials, Ferroelectrics, 39, 1245, 10.1080/00150198108219625 · doi:10.1080/00150198108219625
- Zhang, 2011, Fabrication of angle beam two-element ultrasonic transducers with PMN–PT single crystal and PMN–PT/epoxy 1–3 composite for NDE applications, Sensors Actuators A Phys., 168, 223, 10.1016/j.sna.2011.04.004 · DOI
- Rittenmyer, 1982, Piezoelectric 3–3 composites, Ferroelectrics, 41, 189, 10.1080/00150198208210623 · doi:10.1080/00150198208210623
- Safari, 1982, Perforated PZT-polymer composites for piezoelectric transducer applications, Ferroelectrics, 41, 197, 10.1080/00150198208210624 · doi:10.1080/00150198208210624
- Zhang, 1995, A new transverse piezoelectric mode 2-2 piezocomposite for underwater transducer applications, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 42, 774, 10.1109/58.393119 · doi:10.1109/58.393119
- Fei, 2015, Design of matching layers for high-frequency ultrasonic transducers, Appl. Phys. Lett., 107, 123505, 10.1063/1.4931703 · doi:10.1063/1.4931703
- Crecraft, 1983, Ultrasonic instrumentation: Principles, methods and applications, J. Phys. E: Sci. Instrum., 16, 181, 10.1088/0022-3735/16/3/001 · doi:10.1088/0022-3735/16/3/001
- Fang, 2016, Anodic aluminum oxide–epoxy composite acoustic matching layers for ultrasonic transducer application, Ultrasonics, 70, 29, 10.1016/j.ultras.2016.04.003 · doi:10.1016/j.ultras.2016.04.003
- Amoroso, L., Ramadas, S.N., Klieber, C., Gomez Alvarez-Arenas, T.E., and McNally, T. (2019, January 6–9). Novel Nanocomposite Materials for Improving Passive Layers in Air-coupled Ultrasonic Transducer Applications. Proceedings of the 2019 IEEE International Ultrasonics Symposium (IUS), Glasgow, UK. · doi:10.1109/ultsym.2019.8925712
- Lau, 2009, Multiple matching scheme for broadband 0.72Pb(Mg1/3Nb2/3)O3−0.28PbTiO3 single crystal phased-array transducer, J. Appl. Phys., 105, 94908, 10.1063/1.3065476 · doi:10.1063/1.3065476
- Whittingham, 1999, Broadband transducers, Eur. Radiol., 9, S298, 10.1007/PL00014060 · doi:10.1007/pl00014060
- Xiang, S.H., and Zhang, Y.T. (1995, January 20–23). Matching Layer Optimization Between Ultrasound Transducer and Human Tissues. Proceedings of the 17th International Conference of the Engineering in Medicine and Biology Society, Montreal, QC, Canada.
- Lu, 1994, Biomedical ultrasound beam forming, Ultrasound Med. Biol., 20, 403, 10.1016/0301-5629(94)90097-3 · doi:10.1016/0301-5629(94)90097-3
- Krautkramer, J., and Krautkramer, H. (1975). Ultrasonic Testing of Materials, Springer.
- Wang, 2013, Cylindrically shaped ultrasonic linear array fabricated using PIMNT/epoxy 1-3 piezoelectric composite, Sensors Actuators A Phys., 192, 69, 10.1016/j.sna.2012.12.020 · DOI
- Wang, 2011, An imaging model incorporating ultrasonic transducer properties for three-dimensional optoacoustic tomography, IEEE Trans. Med. Imaging, 30, 203, 10.1109/TMI.2010.2072514 · doi:10.1109/tmi.2010.2072514
- Yue, 2014, Fabrication of a PMN-PT single crystal-based transcranial doppler transducer and the power regulation of its detection system, Sensors, 14, 24462, 10.3390/s141224462 · doi:10.3390/s141224462
- Fei, 2016, Ultrahigh frequency (100 MHz–300 MHz) ultrasonic transducers for optical resolution medical imagining, Sci. Rep., 6, 28360, 10.1038/srep28360 · doi:10.1038/srep28360
- Kelly, S.P., Hayward, G., and Gomez, T.E. (2001, January 7–10). An Air-coupled Ultrasonic Matching Layer Employing Half Wavelength Cavity Resonance. Proceedings of the 2001 IEEE Ultrasonics Symposium, Atlanta, GA, USA.
- Haller, 1994, Micromachined 1–3 composites for ultrasonic air transducers, Rev. Sci. Instrum., 65, 2095, 10.1063/1.1145231 · doi:10.1063/1.1145231
- Hsu, 2012, Focused high frequency needle transducer for ultrasonic imaging and trapping, Appl. Phys. Lett., 101, 24105, 10.1063/1.4736731 · doi:10.1063/1.4736731
- Cannata, 2006, Development of a 35-MHz piezo-composite ultrasound array for medical imaging, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 53, 224, 10.1109/TUFFC.2006.1588408 · doi:10.1109/tuffc.2006.1588408
- Bezanson, 2014, Fabrication and performance of a miniaturized 64-element high-frequency endoscopic phased array, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 61, 33, 10.1109/TUFFC.2014.6689774 · doi:10.1109/tuffc.2014.6689774
- Kossoff, 1966, The effects of backing and matching on the performance of piezoelectric ceramic transducers, IEEE Trans. Sonics Ultrason., 13, 20, 10.1109/T-SU.1966.29370 · doi:10.1109/t-su.1966.29370
- Souquet, 1979, Design of low-loss wide-band ultrasonic transducers for noninvasive medical application, IEEE Trans. Sonics Ultrason., 26, 75, 10.1109/T-SU.1979.31070 · doi:10.1109/t-su.1979.31070
- Goll, 1979, The design of broad-band fluid-loaded ultrasonic transducers, IEEE Trans. Sonics Ultrason., 26, 385, 10.1109/T-SU.1979.31122 · doi:10.1109/t-su.1979.31122
- Szabo, T.L. (2014). Chapter 5 - Transducers. Diagnostic Ultrasound Imaging: Inside Out (Second Edition), Academic Press. · doi:10.1016/b978-0-12-396487-8.00005-7
- Goll, 1975, Multilayer impedance matching schemes for broadbanding of water loaded piezoelectric transducers and high Q electric resonators, IEEE Trans. Sonics Ultrason., 22, 52, 10.1109/T-SU.1975.30776 · doi:10.1109/t-su.1975.30776
- Manh, 2014, Microfabrication of stacks of acoustic matching layers for 15MHz ultrasonic transducers, Ultrasonics, 54, 614, 10.1016/j.ultras.2013.08.015 · doi:10.1016/j.ultras.2013.08.015
- Haller, M.I., and Khuri-Yakub, B.T. (November, January 31). Tapered Acoustic Matching Layers. Proceedings of the 1993 IEEE Ultrasonics Symposium, Baltimore, MD, USA. · doi:10.1109/ultsym.1993.339558
- Ma, 2015, An acoustic filter based on layered structure, Appl. Phys. Lett., 106, 111903, 10.1063/1.4915100 · doi:10.1063/1.4915100
- Sittig, 1968, High-speed ultrasonic digital delay line design: A restatement of some basic considerations, Proc. IEEE, 56, 1194, 10.1109/PROC.1968.6516 · doi:10.1109/proc.1968.6516
- Reeder, 1969, Characteristics of microwave acoustic transducers for volume wave excitation, IEEE Trans. Microw. Theory Tech., 17, 927, 10.1109/TMTT.1969.1127083 · doi:10.1109/tmtt.1969.1127083
- Mason, 1972, 5 - Design and Technology of Piezoelectric Transducers for Frequencies Above 100 MHz, Physical Acoustics, Vol. 9, 221, 10.1016/B978-0-12-395670-5.50010-6 · doi:10.1016/b978-0-12-395670-5.50010-6
- Leedom, 1971, Equivalent circuits for transducers having arbitrary even- or odd-symmetry piezoelectric excitation, IEEE Trans. Sonics Ultrason., 18, 128, 10.1109/T-SU.1971.29608 · doi:10.1109/t-su.1971.29608
- Rhee, S., Ritter, T.A., Shung, K.K., Wang, H., and Cao, W. (2001, January 7–10). Materials for Acoustic Matching in Ultrasound Transducers. Proceedings of the 2001 IEEE Ultrasonics Symposium, Atlanta, GA, USA.
- Stewart, 1922, Acoustic wave filters, Phys. Rev., 20, 528, 10.1103/PhysRev.20.528 · doi:10.1103/physrev.20.528
- Stewart, 1925, Acoustic wave filters: An extension of the theory, Phys. Rev., 25, 90, 10.1103/PhysRev.25.90 · doi:10.1103/physrev.25.90
- Lindsay, 1929, Note on the theory of acoustic wave filters, Phys. Rev., 34, 652, 10.1103/PhysRev.34.652 · doi:10.1103/physrev.34.652
- Myhre, 2017, Analysis of acoustic impedance matching in dual-band ultrasound transducers, J. Acoust. Soc. Am., 141, 1170, 10.1121/1.4976096 · doi:10.1121/1.4976096
- Toda, 2010, Novel multi-layer polymer-metal structures for use in ultrasonic transducer impedance matching and backing absorber applications, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 57, 2818, 10.1109/TUFFC.2010.1755 · doi:10.1109/tuffc.2010.1755
- Toda, 2012, Detailed investigations of polymer/metal multilayer matching layer and backing absorber structures for wideband ultrasonic transducers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 59, 231, 10.1109/TUFFC.2012.2183 · doi:10.1109/tuffc.2012.2183
- Brown, 2014, Mass-spring matching layers for high-frequency ultrasound transducers: A new technique using vacuum deposition, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 61, 1911, 10.1109/TUFFC.2014.006480 · doi:10.1109/tuffc.2014.006480
- Kinsler, L.E., and Frey, A.R. (1962). Fundamentals of Acoustics, Wiley.
- Edmonds, 1981, 1. Piezoelectric Transducers, Ultrasonics, Vol. 19, 29, 10.1016/S0076-695X(08)60332-4 · doi:10.1016/s0076-695x(08)60332-4
- Temkin, S. (1981). Elements of Acoustics, Wiley.
- Cannata, 2003, Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 50, 1548, 10.1109/TUFFC.2003.1251138 · doi:10.1109/tuffc.2003.1251138
- Nicolaides, 2010, The effect of backing material on the transmitting response level and bandwidth of a wideband underwater transmitting transducer using 1-3 piezocomposite material, Phys. Procedia, 3, 1041, 10.1016/j.phpro.2010.01.134 · doi:10.1016/j.phpro.2010.01.134
- Webster, R.A., Button, T.W., Meggs, C., MacLennan, D., and Cochran, S. (2007, January 28–31). P3K-5 Passive Materials for High Frequency Ultrasound Components. Proceedings of the 2007 IEEE Ultrasonics Symposium, New York, NY, USA. · doi:10.1109/ultsym.2007.484
- Grewe, 1990, Acoustic properties of particle/polymer composites for ultrasonic transducer backing applications, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 37, 506, 10.1109/58.63106 · doi:10.1109/58.63106
- Lutsch, 1962, Solid mixtures with specified impedances and high attenuation for ultrasonic waves, J. Acoust. Soc. Am., 34, 131, 10.1121/1.1909002 · doi:10.1121/1.1909002
- Karpelson, 2004, Operation of highly focussed immersion ultrasonic transducers at elevated temperatures, NDT.net, 9, 12
- Holmes-Siedle, A., and Adams, L. (1993). Handbook of Radiation Effects, Oxford Univ Press, Inc.
- Milkovich, 1986, Space radiation effects on the thermo-mechanical behavior of graphite-epoxy composites, J. Compos. Mater., 20, 579, 10.1177/002199838602000605 · doi:10.1177/002199838602000605
- Vandergriff, K.U. (1990). Designing Equipment for Use in Gamma Radiation Environments, Oak Ridge National Lab. · doi:10.2172/814580
- Parkinson, 1971, The use of plastics and elastomers in nuclear radiation, Nucl. Eng. Des., 17, 247, 10.1016/0029-5493(71)90026-4 · doi:10.1016/0029-5493(71)90026-4
- Bonin, 1998, Radiation effects on aluminum-epoxy adhesive joints, J. Appl. Polym. Sci., 67, 37, 10.1002/(SICI)1097-4628(19980103)67:1<37::AID-APP5>3.0.CO;2-P · doi:10.1002/(sici)1097-4628(19980103)67:1<37::aid-app5>3.0.co;2-p
- Schwank, 1990, Total-dose radiation-induced degradation of thin film ferroelectric capacitors, IEEE Trans. Nucl. Sci., 37, 1703, 10.1109/23.101180 · doi:10.1109/23.101180
- Clegg, D.W., and Collyer, A.A. (1991). Irradiation Effects on Polymers, Springer.
- Haider, 2018, Effects of Gamma radiation on resonant and antiresonant characteristics of piezoelectric wafer active sensors, ASME J. Nondestruct. Eval., 2, 011001, 10.1115/1.4041068 · doi:10.1115/1.4041068
- 2008, High temperature ultrasonic transducers: Review, Ultrasound, 63, 7
- Kazys, 2005, High temperature ultrasonic transducers for imaging and measurements in a liquid Pb/Bi eutectic alloy, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 52, 525, 10.1109/TUFFC.2005.1428033 · doi:10.1109/tuffc.2005.1428033
- Sinclair, A.N., and Malkin, R. (2020). Sensors for Ultrasonic Nondestructive Testing (NDT) in Harsh Environments. Sensors, 20. · doi:10.3390/s20020456
- Lee, 1992, Total-dose radiation effects on sol-gel derived PZT thin films, IEEE Trans. Nucl. Sci., 39, 2036, 10.1109/23.211401 · doi:10.1109/23.211401
- Boychenko, D.V., Nikiforov, A.Y., Skorobogatov, P.K., and Sogoyan, A.V. (2007, January 10–14). Radiation Effects in Pezoelectric Sensor. Proceedings of the 2007 9th European Conference on Radiation and its Effects on Components and Systems, Deauville, France. · doi:10.1109/radecs.2007.5205522
- Benedetto, 1990, The effect of ionizing radiation on sol-gel ferroelectric PZT capacitors, IEEE Trans. Nucl. Sci., 37, 1713, 10.1109/23.101181 · doi:10.1109/23.101181
- Smilie, 1983, Mechanisms of transducer failure in a gamma radiation field, Mater. Eval., 41, 1409
- Zhou, 2009, Alumina/epoxy nanocomposite matching layers for high-frequency ultrasound transducer application, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 56, 213, 10.1109/TUFFC.2009.1021 · doi:10.1109/tuffc.2009.1021
- Tiefensee, 2010, Nanocomposite cerium oxide polymer matching layers with adjustable acoustic impedance between 4 MRayl and 7 MRayl, Ultrasonics, 50, 363, 10.1016/j.ultras.2009.08.012 · doi:10.1016/j.ultras.2009.08.012
- Wang, 2004, Silicon oxide colloidal/polymer nanocomposite films, Appl. Phys. Lett., 85, 5998, 10.1063/1.1836018 · doi:10.1063/1.1836018
- Wang, 2009, Su-8-based nanocomposites for acoustical matching layer, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 56, 1483, 10.1109/TUFFC.2009.1204 · doi:10.1109/tuffc.2009.1204
- Manh, 2013, Microfabricated 1–3 composite acoustic matching layers for 15MHz transducers, Ultrasonics, 53, 1141, 10.1016/j.ultras.2013.02.010 · doi:10.1016/j.ultras.2013.02.010
- Manh, T., Jensen, G.U., Johansen, T.F., and Hoff, L. (2012, January 7–10). Modeling and Characterization of a Silicon-epoxy 2-2 Composite Material. Proceedings of the 2012 IEEE International Ultrasonics Symposium, Dresden, Germany. · doi:10.1109/ultsym.2012.0558
- Kim, 2010, Fabrication and comparison of PMN-PT single crystal, PZT and PZT-based 1-3 composite ultrasonic transducers for NDE applications, Ultrasonics, 50, 790, 10.1016/j.ultras.2010.04.001 · doi:10.1016/j.ultras.2010.04.001
- Chen, 2013, Endoscopic ultrasound radial array transducers fabricated with PZT tube by a rotate-and-dice method, Sensors Actuators A Phys., 201, 357, 10.1016/j.sna.2013.07.015 · doi:10.1016/j.sna.2013.07.015
- Vincent, 2015, Polymer foaming with chemical blowing agents: Experiment and modeling, Polym. Eng. Sci., 55, 2018, 10.1002/pen.24044 · doi:10.1002/pen.24044
- Chen, J., and Panda, R. (2005, January 18–21). Review: Commercialization of Piezoelectric Single Crystals for Medical Imaging Applications. Proceedings of the IEEE Ultrasonics Symposium, Rotterdam, The Netherlands.
- Ming Lu, X., and Proulx, T.L. (2005, January 18–21). Single Crystals vs. PZT Ceramics for Medical Ultrasound Applications. Proceedings of the IEEE Ultrasonics Symposium, Rotterdam, The Netherlands.
- Wang, 2011, Applications of antireflection coatings in sonic crystal-based acoustic devices, Phys. Lett. A, 375, 1348, 10.1016/j.physleta.2011.02.004 · doi:10.1016/j.physleta.2011.02.004
- Elliott, 2014, Omnidirectional acoustic absorber with a porous core and a metamaterial matching layer, J. Appl. Phys., 115, 204902, 10.1063/1.4876119 · doi:10.1063/1.4876119
- Jiang, 2014, Broadband field rotator based on acoustic metamaterials, Appl. Phys. Lett., 104, 83510, 10.1063/1.4866333 · doi:10.1063/1.4866333
- Shen, 2014, Anisotropic complementary acoustic metamaterial for canceling out aberrating layers, Phys. Rev. X, 4, 41033
- Wei, 2014, Symmetrical and anti-symmetrical coherent perfect absorption for acoustic waves, Appl. Phys. Lett., 104, 121902, 10.1063/1.4869462 · doi:10.1063/1.4869462
- Yang, 2015, Subwavelength total acoustic absorption with degenerate resonators, Appl. Phys. Lett., 107, 104104, 10.1063/1.4930944 · doi:10.1063/1.4930944
- Song, 2014, Acoustic coherent perfect absorbers, New J. Phys., 16, 33026, 10.1088/1367-2630/16/3/033026 · doi:10.1088/1367-2630/16/3/033026
- Ding, 2016, Emergence, coalescence, and topological properties of multiple exceptional points and their experimental realization, Phys. Rev. X, 6, 21007
- Lee, 2017, Acoustic wave science realized by metamaterials, Nano Converg., 4, 3, 10.1186/s40580-017-0097-y · doi:10.1186/s40580-017-0097-y
- Peng, 2011, Extraordinary acoustic shielding by a monolayer of periodical polymethyl methacrylate cylinders immersed in water, J. Appl. Phys., 110, 14509, 10.1063/1.3601746 · doi:10.1063/1.3601746
- Li, 2015, Metascreen-based acoustic passive phased array, Phys. Rev. Appl., 4, 24003, 10.1103/PhysRevApplied.4.024003 · doi:10.1103/physrevapplied.4.024003
- Tang, 2015, Focusing and directional beaming effects of airborne sound through a planar lens with zigzag slits, J. Appl. Phys., 117, 24503, 10.1063/1.4905910 · doi:10.1063/1.4905910
- Zigoneanu, 2011, Design and measurements of a broadband two-dimensional acoustic lens, Phys. Rev. B, 84, 24305, 10.1103/PhysRevB.84.024305 · doi:10.1103/physrevb.84.024305
- Le, 2012, Broadband metamaterial for nonresonant matching of acoustic waves, Sci. Rep., 2, 340, 10.1038/srep00340 · doi:10.1038/srep00340
- Xie, 2013, Tapered labyrinthine acoustic metamaterials for broadband impedance matching, Appl. Phys. Lett., 103, 201906, 10.1063/1.4831770 · doi:10.1063/1.4831770
- Fleury, 2014, Metamaterial buffer for broadband non-resonant impedance matching of obliquely incident acoustic waves, J. Acoust. Soc. Am., 136, 2935, 10.1121/1.4900567 · doi:10.1121/1.4900567
- Wu, 2016, High transmission acoustic focusing by impedance-matched acoustic meta-surfaces, Appl. Phys. Lett., 108, 31902, 10.1063/1.4939932 · doi:10.1063/1.4939932
- Tang, 2017, Total transmission of airborne sound by impedance-matched ultra-thin metasurfaces, J. Phys. D. Appl. Phys., 50, 105102, 10.1088/1361-6463/aa5a86 · doi:10.1088/1361-6463/aa5a86
- Ding, 2017, A broadband acoustic metamaterial with impedance matching layer of gradient index, Appl. Phys. Lett., 110, 241903, 10.1063/1.4986472 · doi:10.1063/1.4986472
- Pedersen, 1982, Impedance-matching properties of an inhomogeneous matching layer with continuously changing acoustic impedance, J. Acoust. Soc. Am., 72, 327, 10.1121/1.388085 · doi:10.1121/1.388085
- Guild, 2015, Acoustic metamaterial absorbers based on multilayered sonic crystals, J. Appl. Phys., 117, 114902, 10.1063/1.4915346 · doi:10.1063/1.4915346
- Yao, 2016, Photonic crystals with broadband, wide-angle, and polarization-insensitive transparency, Opt. Lett., 41, 5106, 10.1364/OL.41.005106 · doi:10.1364/ol.41.005106
- Liu, 2018, Acoustic metamaterials with broadband and wide-angle impedance matching, Phys. Rev. Mater., 2, 45201, 10.1103/PhysRevMaterials.2.045201 · DOI
- Ba, 2017, Soft porous silicone rubbers with ultra-low sound speeds in acoustic metamaterials, Sci. Rep., 7, 40106, 10.1038/srep40106 · doi:10.1038/srep40106
- 2000, Transverse elastic waves in superlattices: The Brewster acoustic angle, Phys. Rev. B, 61, 12877, 10.1103/PhysRevB.61.12877 · doi:10.1103/physrevb.61.12877
- Shen, 2011, Microscale 1–3-type (Na,K)NbO3-based Pb-free piezocomposites for high-frequency ultrasonic transducer applications, J. Am. Ceram. Soc., 94, 1346, 10.1111/j.1551-2916.2011.04508.x · doi:10.1111/j.1551-2916.2011.04508.x
- Sorokin, 2017, Excitation of hypersonic acoustic waves in diamond-based piezoelectric layered structure on the microwave frequencies up to 20GHz, Ultrasonics, 78, 162, 10.1016/j.ultras.2017.01.014 · doi:10.1016/j.ultras.2017.01.014
- Zhang, 2006, High-tone bulk acoustic resonators on sapphire, crystal quartz, fused silica, and silicon substrates, J. Appl. Phys., 99, 124911, 10.1063/1.2209029 · doi:10.1063/1.2209029
- Zhang, 2003, Resonant spectrum method to characterize piezoelectric films in composite resonators, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 50, 321, 10.1109/TUFFC.2003.1193626 · doi:10.1109/tuffc.2003.1193626
- Lakin, 2005, Thin film resonator technology, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 52, 707, 10.1109/TUFFC.2005.1503959 · doi:10.1109/tuffc.2005.1503959
- Akhbari, 2016, Bimorph piezoelectric micromachined ultrasonic transducers, J. Microelectromechanical Syst., 25, 326, 10.1109/JMEMS.2016.2516510 · doi:10.1109/jmems.2016.2516510
- Lee, W., Kim, S., Jung, J., Kang, W., Shin, E., Moon, C., and Choi, H. (2016, January 18–21). Mechanosensitive Channel Stimulation System Using Low-Intensity Ultrasound by Piezoelectric Micromachined Ultrasonic Transducer Array. Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS), Tours, France. · DOI
- Rupitsch, 2011, Ultrasound transducers based on ferroelectret materials, IEEE Trans. Dielectr. Electr. Insul., 18, 69, 10.1109/TDEI.2011.5704495 · doi:10.1109/tdei.2011.5704495
- Ealo, 2010, Ultrasonic air-coupled inspection of textile materials using ferroelectret-based phased arrays, AIP Conf. Proc., 1211, 933, 10.1063/1.3362529 · doi:10.1063/1.3362529
- Gaal, 2013, Ferroelectret transducers for air-coupled ultrasonic testing of fiber-reinforced polymers, AIP Conf. Proc., 1511, 1534, 10.1063/1.4789224 · doi:10.1063/1.4789224
- 2013, Shear waves in vegetal tissues at ultrasonic frequencies, Appl. Phys. Lett., 102, 103702, 10.1063/1.4795785 · doi:10.1063/1.4795785
- Gan, 2002, Preliminary studies of a novel air-coupled ultrasonic inspection system for food containers, J. Food Eng., 53, 315, 10.1016/S0260-8774(01)00172-8 · doi:10.1016/s0260-8774(01)00172-8
- Chimenti, 2014, Review of air-coupled ultrasonic materials characterization, Ultrasonics, 54, 1804, 10.1016/j.ultras.2014.02.006 · doi:10.1016/j.ultras.2014.02.006
- Dahl, 2014, Applications of airborne ultrasound in human–computer interaction, Ultrasonics, 54, 1912, 10.1016/j.ultras.2014.04.008 · doi:10.1016/j.ultras.2014.04.008
200 of 302 shown
Cited by
Nsengiyumva, W., Zhong, S., Lin, J., Zhang, Q., Zhong, J., & Huang, Y. (2021) · Composite Structures · doi:10.1016/j.compstruct.2020.112951 · Cited by 325
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Wireless power transfer: systems, circuits, standards, and use cases
Van Mulders, J., Delabie, D., Lecluyse, C., Buyle, C., Callebaut, G., Van der Perre, L., & De Strycker, L. (2022) · Sensors · doi:10.3390/s22155573 · Cited by 141
Capineri, L., & Bulletti, A. (2021) · doi:10.20944/preprints202103.0347.v2 · Cited by 131
Metadata
- Authors
- Rathod, V. T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-07-21
- Volume
- 20
- Issue
- 14
- Pages
- 4051
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3045443807
- Cited by
- 328
- References
- 171
- FWCI
- 15.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.