A Hybrid Deep CNN Model for Abnormal Arrhythmia Detection Based on Cardiac ECG Signal
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Electrocardiogram (ECG) signals play a vital role in diagnosing and monitoring patients suffering from various cardiovascular diseases (CVDs). This research aims to develop a robust algorithm that can accurately classify the electrocardiogram signal even in the presence of environmental noise. A one-dimensional convolutional neural network (CNN) with two convolutional layers, two down-sampling layers, and a fully connected layer is proposed in this work. The same 1D data was transformed into two-dimensional (2D) images to improve the model’s classification accuracy. Then, we applied the 2D CNN model consisting of input and output layers, three 2D-convolutional layers, three down-sampling layers, and a fully connected layer. The classification accuracy of 97.38% and 99.02% is achieved with the proposed 1D and 2D model when tested on the publicly available Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database. Both proposed 1D and 2D CNN models outperformed the corresponding state-of-the-art classification algorithms for the same data, which validates the proposed models’ effectiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Burden of Cardiovascular Disease and Stroke: Hypertension at the Core
Lackland, D. T., & Weber, M. A. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.01.009 · Cited by 352 · cited 1×
“The World Heart Federation report witness about three fourth of the total cardiovascular disease (CVD) patients reside inside low-income regions across the globe [1].”
BackgroundSatija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
Evans, G. F., Shirk, A., Muturi, P., & Soliman, E. Z. (2017) · Global Heart · doi:10.1016/j.gheart.2016.12.003 · Cited by 54 · cited 1×
“Although the electricity amount is, in fact, very small, it can be picked up reliably with ECG electrodes attached to the skin (in microvolts, or uV) [2].”
Background
Cited by
Javed, H., El-Sappagh, S., & Abuhmed, T. (2024) · Artificial Intelligence Review · doi:10.1007/s10462-024-11005-9 · Cited by 180
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Alam, M. S. B., Lameesa, A., Sharmin, S., Afrin, S., Ahmed, S. F., Nikoo, M. R., & Gandomi, A. H. (2025) · Digital Communications and Networks · doi:10.1016/j.dcan.2025.04.001 · Cited by 9
Metadata
- Authors
- Ullah, A., Rehman, S. U., Tu, S., Mehmood, R. M., Fawad, & Ehatisham-ul-haq, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-02-01
- Volume
- 21
- Issue
- 3
- Pages
- 951
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3129130955
- Cited by
- 175
- References
- 3
- FWCI
- 18.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Hybrid Deep CNN Model for Abnormal Arrhythmia Detection Based on Cardiac ECG Signal. https://app.cochat.ai/papers/10.3390/s21030951
- The paper
- Ullah, A., Rehman, S. U., Tu, S., Mehmood, R. M., Fawad, & Ehatisham-ul-haq, M. (2021). A Hybrid Deep CNN Model for Abnormal Arrhythmia Detection Based on Cardiac ECG Signal. Sensors. https://doi.org/10.3390/s21030951
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.