Abstract

The radiation captured in spectral imaging depends on both the complex light–matter interaction and the integration of the radiant light by the imaging system. In order to obtain material-specific information, it is important to define and invert an imaging process that takes into account both aspects. In this article, we investigate the use of several mixing models and evaluate their performances in the study of oil paintings. We propose an evaluation protocol, based on different features, i.e., spectral reconstruction, pigment mapping, and concentration estimation, which allows investigating the different properties of those mixing models in the context of spectral imaging. We conduct our experiment on oil-painted mockup samples of mixtures and show that models based on subtractive mixing perform the best for those materials.

Overview

CoChat Summary

TL;DR

This paper compares seven imaging/mixing models for spectral unmixing of oil-painted mockups and a mockup painting, evaluating spectral reconstruction, pigment mapping, and concentration estimation. Models based on subtractive mixing performed best overall for these materials.

Key findings

  • In the model expectation test, subtractive models fared best, followed by hybrid models, then additive models; among hybrids, subtractive-oriented M5 had better MSE than additive-oriented M4.
  • In prediction and full unmixing, the same ranking was confirmed, with the pure subtractive model most often selected; in unmixing, MSE scale was reduced by approximately a factor of 10, while concentration error Δα was slightly higher than in prediction.
  • For pigment identification, hybrid models M3, M4, and M5 had slightly better cut-off αT values than subtractive M2 and M7, but accuracy, precision, recall, and F1 differences indicated a preference for subtractive-based models.
  • On the validation mockup painting, subtractive-based models correctly identified Kremer White in the lower sky and correctly identified the absence of Carmine in the right face area, whereas additive-based models did not fully appreciate the white and detected Carmine where it was absent; Naples Yellow was strongly misidentified with Gold Ochre.

Methods

  • Seven mixing models were compared: additive linear M1; subtractive weighted geometric mean M2; hybrid Yule–Nielsen M3, Additive-Subtractive M4, and Subtractive-Additive M5; and logarithmic image processing (LIP) versions M6 and M7. Hybrid mixing constant τ was arbitrarily set to 0.5.
  • Mockup samples used seven Kremer pigments in an oil-painting Renaissance palette; mixtures included up to three pigments, with all two-pigment combinations at 1:1 and 2:1 ratios and three-pigment combinations at 2:1:1, totaling 175 mixtures on 2×2 cm patches. Hyperspectral images were captured with a HySpex VNIR-1800 pushbroom camera from 400 to 1000 nm, with 186 bands, 3.26 nm spectral sampling, and 166 data points after omitting the first and last 10 bands; a mockup painting served as validation.
  • Spectral unmixing used Nelder–Mead constrained optimization with non-negativity and sum-to-one constraints, minimizing MSE; concentration error Δα was the Euclidean distance between ground-truth and estimated concentration vectors, and a combined score w = MSE + Δα/√2 was used. Three tasks were run: model expectation, prediction, and full unmixing; pigment detection thresholds were derived from ROC curves using the Youden Index, with accuracy, precision, recall, and F1 reported.

Limitations

  • The paper states that all models assume diffuse reflections and do not handle specularities or BRDFs, and specularities were observed in the mockups. It also states that radiative transfer models such as Kubelka–Munk and four-flux were excluded because they require scattering and absorption coefficients and applicability conditions.
  • The paper states that the concentration error does not consider the scale of concentrations, only the magnitude of differences; false positives could be highly penalized; good unmixing does not imply good rendering; and future joint analysis of unmixing and rendering is needed. It also notes that the hybrid τ was set arbitrarily to 0.5 and that the αT values may be too high from a conservation standpoint, as concentrations around 10% might be significant but would be neglected.
  • Evident from the text: the study is limited to seven pigments, oil mockups, and the VNIR range (400–1000 nm), with no SWIR evaluation; the validation painting was spatially down-sampled by a factor of 10 without interpolation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/s21072471

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Three possible configurations of pigment mixing. (a): Optical blending occurs when two materials are physically separated but mixed at the camera level. (b): A layered structure assumes that light is transmitted and reflected according to the properties of the different layers. (c): In the intimate mixing the components are not physically discernible.
Figure 1 Three possible configurations of pigment mixing. (a): Optical blending occurs when two materials are physically separated but mixed at the camera level. (b): A layered structure assumes that light is transmitted and reflected according to the properties of the different layers. (c): In the intimate mixing the components are not physically discernible.CC BY · PubMed Central
Figure 2 Set of mockup samples realised for the experiment. The 175 painted patches are ordered according to a script, not considering perceptual similarities. Reproduced from [29] with permission from the International Colour Association (AIC).
Figure 2 Set of mockup samples realised for the experiment. The 175 painted patches are ordered according to a script, not considering perceptual similarities. Reproduced from [29] with permission from the International Colour Association (AIC).CC BY · PubMed Central
Figure 3 Mockup painting realised with the same set of pigments used for the composition of the mixture samples. Reproduced from [47] with permission from the AIC.
Figure 3 Mockup painting realised with the same set of pigments used for the composition of the mixture samples. Reproduced from [47] with permission from the AIC.CC BY · PubMed Central
Figure 4 Hyperspectral image acquisition setup. The light sources are placed at 45°, while the camera is at 0°. This allows avoiding specular reflection and shadows. In the push broom setup, the translator stage slides across the field of view of the camera at a speed synchronised with the integration time of the camera.
Figure 4 Hyperspectral image acquisition setup. The light sources are placed at 45°, while the camera is at 0°. This allows avoiding specular reflection and shadows. In the push broom setup, the translator stage slides across the field of view of the camera at a speed synchronised with the integration time of the camera.CC BY · PubMed Central
Figure 5 Experimental flow chart. The mockup samples are realised and acquired in a Hyperspectral Imaging (HSI) setup, then the reflectance factors of the patches are estimated (Section 2.2). Each imaging model is evaluated individually. Different features of the imaging models can be observed, depending on the task performed: the model expectation test allows to evaluate the spectral accuracy; the prediction task investigates spectral accuracy and concentration estimation, whereas spectral unmixing comprehends spectral accuracy, concentration estimation, and pigment identification.
Figure 5 Experimental flow chart. The mockup samples are realised and acquired in a Hyperspectral Imaging (HSI) setup, then the reflectance factors of the patches are estimated (Section 2.2). Each imaging model is evaluated individually. Different features of the imaging models can be observed, depending on the task performed: the model expectation test allows to evaluate the spectral accuracy; the prediction task investigates spectral accuracy and concentration estimation, whereas spectral unmixing comprehends spectral accuracy, concentration estimation, and pigment identification.CC BY · PubMed Central
Figure 6 Performances in the model expectation test. (a): Average MSE values and respective 95% confidence intervals. (b): Number of times each model has been selected as best or worst in terms of MSE.
Figure 6 Performances in the model expectation test. (a): Average MSE values and respective 95% confidence intervals. (b): Number of times each model has been selected as best or worst in terms of MSE.CC BY · PubMed Central
Figure 7 Performances in the prediction task. All error bars refer to 95% confidence intervals. (a): Mean w score. (b): Number of times each model has been selected as best or worst in terms of w score. (c): Average MSE. (d): Mean concentration error Δα.
Figure 7 Performances in the prediction task. All error bars refer to 95% confidence intervals. (a): Mean w score. (b): Number of times each model has been selected as best or worst in terms of w score. (c): Average MSE. (d): Mean concentration error Δα.CC BY · PubMed Central
Figure 8 Performances in the spectral unmixing task. All error bars refer to 95% confidence intervals. (a): Mean w score. (b): Number of times each model has been selected as best or worst in terms of w score. (c): Average MSE. (d): Mean concentration error Δα.
Figure 8 Performances in the spectral unmixing task. All error bars refer to 95% confidence intervals. (a): Mean w score. (b): Number of times each model has been selected as best or worst in terms of w score. (c): Average MSE. (d): Mean concentration error Δα.CC BY · PubMed Central
Figure 9 Performances of pigment detection. (a): The scores are calculated at the concentration thresholds reported in Table 3. (b): The scores are computed at a fixed αT=0.15. The overall detection performance is slightly poorer when a fixed αT is used, as it is observable by the small decreases in accuracy. At the same time, the trade-off between precision and recall yields very similar F1 scores in both conditions (a,b).
Figure 9 Performances of pigment detection. (a): The scores are calculated at the concentration thresholds reported in Table 3. (b): The scores are computed at a fixed αT=0.15. The overall detection performance is slightly poorer when a fixed αT is used, as it is observable by the small decreases in accuracy. At the same time, the trade-off between precision and recall yields very similar F1 scores in both conditions (a,b).CC BY · PubMed Central
Figure 10 Pseudo-colour concentration maps related to each pigment (by column) and investigated imaging models (by row). The best performances are obtained by the subtractive-based models, whereas the additive-based models reported the poorest results.
Figure 10 Pseudo-colour concentration maps related to each pigment (by column) and investigated imaging models (by row). The best performances are obtained by the subtractive-based models, whereas the additive-based models reported the poorest results.CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 2 Not valid · 11 Not checked · 31 Own results and interpretations

14 more claims

Create a free account to see all 44 claims and to verify the 17 references still open.

See all claims — free account
  • It may state two separate claims as one. 12
  • Probably not a substantial claim. 15

Create a free account to see these claims.

Citations

Cites

Show all 47 references

Research works printed but not linked: 2

  1. Grillini F. Thomas J.B. George S. Mixing models in close-range spectral imaging for pigment mapping in cultural heritage Proceedings of the International Colour Association (AIC) Conference 2020 Avignon, France 20, 26–27 November 2020 372 376
  2. Yule J. Nielsen W. The penetration of light into paper and its effect on halftone reproduction Proc. TAGA 1951 3 65 76

Cited by

See all 43

Metadata

Authors
Grillini, F., Thomas, J.-B., & George, S.
Affiliations
  • Norwegian University of Science and Technology (NO)
  • Université de Bourgogne (FR)
Corresponding author
Grillini, Federico
Venue
Sensors
Publisher
MDPI AG
Published
2021-04-02
Volume
21
Issue
7
Pages
2471
ISSN
1424-8220 (ISSN-L)
OpenAlex
W3142984983
Cited by
43
References
48
Citations by year
2026: 10 · 2025: 11 · 2024: 5 · 2023: 9 · 2022: 4 · 2021: 3
FWCI
16.84
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
Funders
Regional Research Council (RFF-Innlandet) of Norway (298914)
Topics
  • Social Sciences › Arts and Humanities › Archeology (arts and humanities) › Cultural Heritage Materials Analysis
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Color Science and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
Keywords
spectral unmixing, oil painting, imaging model, mixing models, spectral reconstruction, pigment mapping, concentration estimation, light-matter interaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-24, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-24 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Imaging Models for Spectral Unmixing in Oil Painting. https://app.cochat.ai/papers/10.3390/s21072471
The paper
Grillini, F., Thomas, J.-B., & George, S. (2021). Comparison of Imaging Models for Spectral Unmixing in Oil Painting. Sensors. https://doi.org/10.3390/s21072471

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.