Wearable IMU-Based Human Activity Recognition Algorithm for Clinical Balance Assessment Using 1D-CNN and GRU Ensemble Model
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
In this study, a wearable inertial measurement unit system was introduced to assess patients via the Berg balance scale (BBS), a clinical test for balance assessment. For this purpose, an automatic scoring algorithm was developed. The principal aim of this study is to improve the performance of the machine-learning-based method by introducing a deep-learning algorithm. A one-dimensional (1D) convolutional neural network (CNN) and a gated recurrent unit (GRU) that shows good performance in multivariate time-series data were used as model components to find the optimal ensemble model. Various structures were tested, and a stacking ensemble model with a simple meta-learner after two 1D-CNN heads and one GRU head showed the best performance. Additionally, model performance was enhanced by improving the dataset via preprocessing. The data were down sampled, an appropriate sampling rate was found, and the training and evaluation times of the model were improved. Using an augmentation process, the data imbalance problem was solved, and model accuracy was improved. The maximum accuracy of 14 BBS tasks using the model was 98.4%, which is superior to the results of previous studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761
A Survey on Human Activity Recognition using Wearable Sensors
Lara, O. D., & Labrador, M. A. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.110112.00192 · Cited by 2,662
Deep learning for sensor-based activity recognition: A survey
Wang, J., Chen, Y., Hao, S., Peng, X., & Hu, L. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2018.02.010 · Cited by 2,014
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
A Comparative Performance Analysis of Data Resampling Methods on Imbalance Medical Data
Khushi, M., Shaukat, K., Alam, T. M., Hameed, I. A., Uddin, S., Luo, S., Yang, X., & Reyes, M. C. (2021) · IEEE Access · doi:10.1109/access.2021.3102399 · Cited by 335
Chung, S., Lim, J., Noh, K. J., Kim, G., & Jeong, H. (2019) · Sensors · doi:10.3390/s19071716 · Cited by 215 · cited 2×
“In Chung’s HAR study [21], data from a multimodal nine degrees-of-freedom IMU was used, and an ensemble model comprising a long short-term memory (LSTM) for each head modality was proposed.”
MethodSelf-citationOptimising sampling rates for accelerometer-based human activity recognition
Khan, A., Hammerla, N., Mellor, S., & Plötz, T. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2016.01.001 · Cited by 171 · cited 1×
“According to a previous IMU-based HAR study, even when the sampling rate for 100–250 Hz data was decreased to 12–42 Hz [29], the performance reduction was small, and even the sampling rate of 10 Hz was sufficiently recognizable [21].”
MethodMekruksavanich, S., & Jitpattanakul, A. (2021) · Electronics · doi:10.3390/electronics10141685 · Cited by 138 · cited 1×
“Mekruksa-Vanich’s study [24] demonstrated a CNN-bidirectional gated recurrent unit (GRU) model that showed better classification performance than a machine-learning model, including a CNN with a GRU, against several IMU-based HAR open datasets.”
MethodMohammadian Rad, N., Van Laarhoven, T., Furlanello, C., & Marchiori, E. (2018) · Sensors · doi:10.3390/s18103533 · Cited by 76
Cited by
Deep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
“The proposed models were evaluated using different metrics, and the best results were observed when combining the CNN with the GRU in [55].”
MethodInertial-Measurement-Unit-Based Novel Human Activity Recognition Algorithm Using Conformer
Kim, Y.-W., Cho, W.-H., Kim, K.-S., & Lee, S. (2022) · Sensors · doi:10.3390/s22103932 · Cited by 31
Self-citationIMU2CLIP: Language-grounded Motion Sensor Translation with Multimodal Contrastive Learning
Moon, S., Madotto, A., Lin, Z., Saraf, A., Bearman, A., & Damavandi, B. (2023) · Findings of the Association for Computational Linguistics: EMNLP 2023 · doi:10.18653/v1/2023.findings-emnlp.883 · Cited by 18
“Various architectures (Kim et al., 2021; Ashry et al., 2020) have been explored for modeling IMU in downstream tasks, including Transformer-CNN based IMU models (Jiang et al., 2022).”
Method
Metadata
- Authors
- Kim, Y.-W., Joa, K.-L., Jeong, H.-Y., & Lee, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-11-17
- Volume
- 21
- Issue
- 22
- Pages
- 7628
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3212071041
- Cited by
- 67
- References
- 9
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.