Stepping towards More Intuitive Physical Activity Metrics with Wrist-Worn Accelerometry: Validity of an Open-Source Step-Count Algorithm
Open accessThe DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Stepping-based targets such as the number of steps per day provide an intuitive and commonly used method of prescribing and self-monitoring physical activity goals. Physical activity surveillance is increasingly being obtained from wrist-worn accelerometers. However, the ability to derive stepping-based metrics from this wear location still lacks validation and open-source methods. This study aimed to assess the concurrent validity of two versions (1. original and 2. optimized) of the Verisense step-count algorithm at estimating step-counts from wrist-worn accelerometry, compared with steps from the thigh-worn activPAL as the comparator. Participants (n = 713), across three datasets, had >24 h continuous concurrent accelerometry wear on the non-dominant wrist and thigh. Compared with activPAL, total daily steps were overestimated by 913 ± 141 (mean bias ± 95% limits of agreement) and 742 ± 150 steps/day with Verisense algorithms 1 and 2, respectively, but moderate-to-vigorous physical activity (MVPA) steps were underestimated by 2207 ± 145 and 1204 ± 103 steps/day in Verisense algorithms 1 and 2, respectively. In summary, the optimized Verisense algorithm was more accurate in detecting total and MVPA steps. Findings highlight the importance of assessing algorithm performance beyond total step count, as not all steps are equal. The optimized Verisense open-source algorithm presents acceptable accuracy for derivation of stepping-based metrics from wrist-worn accelerometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“External validation of the novel model outperformed both reference algorithms, including the Verisense algorithm, which was trained and tuned using the Clemson laboratory dataset10,25.”
From Development and Validation of a Machine Learning Wrist-worn Step Detection Algorithm with Deployment in the UK Biobank (2023) · cites this paper as [10]
Experimental — accuracy not yet measuredIn the citing paper
“many popular open-source step counting algorithms were not developed in accordance with, or lack validation against, direct observation ground truth step counts in a free-living environment8–10.”
From Development and Validation of a Machine Learning Wrist-worn Step Detection Algorithm with Deployment in the UK Biobank (2023) · cites this paper as [10]
In the citing paper
“External validation of the Verisense algorithm10,25, incorporated into recent UK Biobank papers14,26, produced a 63.5% MAPE, 7.2% underestimation bias, and r = 0.85 against free-living ground truth step counts (Supplemental Table 2).”
From Development and Validation of a Machine Learning Wrist-worn Step Detection Algorithm with Deployment in the UK Biobank (2023) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
World Health Organization 2020 guidelines on physical activity and sedentary behaviour
Bull, F. C., Al-Ansari, S. S., Biddle, S., Borodulin, K., Buman, M. P., Cardon, G., Carty, C., Chaput, J.-P., Chastin, S., Chou, R., et al. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102955 · Cited by 11,657 · cited 1×
“Current physical activity guidelines for adults recommend ≥150 min/week of moderate-tovigorous PA (MVPA) for optimal health benefits [5].”
BackgroundSelf-citationEkelund, U., Tarp, J., Steene-Johannessen, J., Hansen, B. H., Jefferis, B., Fagerland, M. W., Whincup, P., Diaz, K. M., Hooker, S. P., Chernofsky, A., et al. (2019) · BMJ · doi:10.1136/bmj.l4570 · Cited by 1,769 · cited 1×
“Physical activity (PA) of any intensity is associated with reduced all-cause mortality [1,2] and reduced risk of chronic disease, including type 2 diabetes [3] and cardiovascular disease [4].”
BackgroundSelf-citationDoherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250 · cited 6×
“Wrist-worn accelerometers are increasingly being used within large-scale population surveillance research [11,16].”
InfluentialMigueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
Self-citationvan Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Ferguson, T., Olds, T., Curtis, R., Blake, H., Crozier, A. J., Dankiw, K., Dumuid, D., Kasai, D., O'Connor, E., Virgara, R., et al. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(22)00111-x · Cited by 605 · cited 1×
“A recent systematic review showed that wearing a consumer physical activity device is effective at increasing physical activity [10].”
BackgroundAssociation of Step Volume and Intensity With All-Cause Mortality in Older Women
Lee, I.-M., Shiroma, E. J., Kamada, M., Bassett, D. R., Matthews, C. E., & Buring, J. E. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.0899 · Cited by 604 · cited 2×
“However, other findings have demonstrated benefits to health outcomes such as cardiovascular disease risk markers, cardiovascular events and all-cause mortality are markedly reduced beyond ~8000 steps a day in adults [2,8,14,15].”
BackgroundDaily steps and all-cause mortality: a meta-analysis of 15 international cohorts
Paluch, A. E., Bajpai, S., Bassett, D. R., Carnethon, M. R., Ekelund, U., Evenson, K. R., Galuska, D. A., Jefferis, B. J., Kraus, W. E., Lee, I.-M., et al. (2022) · The Lancet Public Health · doi:10.1016/s2468-2667(21)00302-9 · Cited by 582
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
Cited by
Ahmadi, M. N., Rezende, L. F. M., Ferrari, G., Cruz, B. D. P., Lee, I.-M. M., & Stamatakis, E. (2024) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-107221 · Cited by 79
Small, S. R., Chan, S., Walmsley, R., von Fritsch, L., Acquah, A., Mertes, G., Feakins, B. G., Creagh, A. P., Strange, A., Matthews, C. E., et al. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003478 · Cited by 57
Small, S. R., Chan, S., Walmsley, R., Fritsch, L. V., Acquah, A., Mertes, G., Feakins, B. G., Creagh, A., Strange, A., Matthews, C. E., et al. (2023) · doi:10.1101/2023.02.20.23285750 · Cited by 22
“…step counting rely on proprietary step counting methods without transparent evaluation 7 , and many popular open-source step counting algorithms were not developed in accordance with, or lack validation against, direct observation ground truth step counts in a free-living environment 8–10 .”
InfluentialToth, L. P., Paluch, A. E., Bassett, D. R., Rees‐Punia, E., EBERL, E. M., Park, S., & Evenson, K. R. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003282 · Cited by 22
Tynan, M. E., Virzi, N. E., Wooldridge, J. S., Morse, J. L., & Herbert, M. S. (2023) · Journal of Pain · doi:10.1016/j.jpain.2023.10.021 · Cited by 16
Schoenfelder, A., Metcalf, B. S., Langford, J., Stathi, A., Western, M. J., & Hillsdon, M. M. (2023) · Sensors · doi:10.3390/s23115122 · Cited by 11
Cruz, B. D. P., Ahmadi, M. N., Sabag, A., Saint‐Maurice, P. F., Lee, I.-M. M., & Stamatakis, E. (2025) · Annals of Internal Medicine · doi:10.7326/annals-25-01547 · Cited by 14
Koffman, L. J., & Muschelli, J. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0008 · Cited by 8
Buchan, D. S. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0026 · Cited by 7
Mendt, S., Zout, G., Rabuffetti, M., Gunga, H., Bunker, A., Barteit, S., & Maggioni, M. A. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1491401 · Cited by 5
Gao, S., Zhou, X., Koffman, L. J., Wanigatunga, A. A., Schrack, J. A., Crainiceanu, C. M., & Muschelli, J. (2025) · The Journals of Gerontology Series A · doi:10.1093/gerona/glaf034 · Cited by 6
Sensors for Human Physical Behaviour Monitoring
Granat, M. H., Holtermann, A., & Lyden, K. A. (2023) · Sensors · doi:10.3390/s23084091 · Cited by 3
Buchan, D. S. (2024) · Journal of Sports Sciences · doi:10.1080/02640414.2024.2404784 · Cited by 3
Using Metabolic Testing to Personalize Behavioral Obesity Treatment
Epstein, L. H., Apolzan, J. W., Moore, M., Neuwald, N. V., & Faith, M. S. (2025) · Obesity Science & Practice · doi:10.1002/osp4.70065 · Cited by 3
WEI, L., Ahmadi, M. N., Blodgett, J. M., Aguiar, E. J., Biswas, R. K., Koemel, N. A., Cruz, B. D. P., & Stamatakis, E. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003887 · Cited by 4
Pina, R., Matos, C. H. C., Cardoso, K., & de Oliveira, D. A. (2024) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2024.2383933 · Cited by 5
Hyde, E. T., Hayes, H. A., Matthews, C. E., Shreves, A. H., Ylarregui, K., Brennan, S., & Keadle, S. K. (2026) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003989 · Cited by 2
Paluch, A. E., Evenson, K. R., EBERL, E. M., Marcotte, S. P., Parvizi, P., Rees‐Punia, E., Toth, L. P., & Bassett, D. R. (2026) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2026.101162 · Cited by 1
Wei, L., Ahmadi, M. N., Blodgett, J. M., Aguiar, E. J., Biswas, R. K., Cruz, B. D. P., & Stamatakis, E. A. (2024) · medRxiv · doi:10.1101/2024.09.10.24313453 · Cited by 1
Marcotte, R. T., Bachman, S. L., Zhai, Y., Clay, I., & Lyden, K. A. (2024) · Digital Biomarkers · doi:10.1159/000542850 · Cited by 1
Lauer, C., Holowka, N. B., Worthington, S., Kraft, T. S., & Wallace, I. J. (2025) · The Anatomical Record · doi:10.1002/ar.25639 · Cited by 1
Benchmarking open-source step counting algorithms for wrist-worn devices
Salvi, D., Caramaschi, S., Sarmiento, C. A., Sekules, V., Olsson, C. M., Angelucci, A., & Aliverti, A. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253635
Forman, D. E., Perera, S., Shiva, S. S., Glynn, N. W., Stakich, T. S., Ramos, S. V., Distéfano, G., Wolf, C., Kendi, A., Sterczala, A. J., et al. (2026) · The Journals of Gerontology Series A · doi:10.1093/gerona/glag034
24-hour Movement Behaviours and Multimorbidity in Malawi: protocol for a cross-sectional study
Warner, B., Gray, S. R., Nkoka, O., Price, A., & Crampin, A. C. (2026) · Wellcome Open Research · doi:10.12688/wellcomeopenres.25945.1
Five-Domain Accelerometer-Derived Behavioral Exposome and Incident Cancer Risk in UK BiobankPreprint
Chin, M. N. C., & Berrio, J. A. (2026) · medRxiv · doi:10.64898/2026.04.07.26350369
Recovery of device‐measured physical activity after major abdominal surgery in older adults
Rubin, D. S., Tingling, K., Huisingh-Scheetz, M. J., & Glynn, N. W. (2026) · Anaesthesia · doi:10.1111/anae.70310
Goldney, J., Rowlands, A. V., Hamza, M., Hall, A. P., Misra, S., Wilmot, E. G., Edwardson, C. L., Khunti, K., Yates, T. E., Daynes, E., et al. (2026) · Metabologia · doi:10.1007/s44357-026-00007-5
Self-citationWei, L., Ahmadi, M. N., Koemel, N. A., Biswas, R. K., Cruz, B. D. P., & Stamatakis, E. (2026) · British Journal of Sports Medicine · doi:10.1136/bjsports-2025-111173
Translating Daily Step Count Targets From Research-Grade Approaches to a Consumer Wearable
Thomas, J. J. C., Edwardson, C. L., Taylor, S., Eckmann, H. R., Donoso, I. A. P., & Rowlands, A. V. (2026) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2026-0026
Self-citation
Metadata
- Authors
- Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V.
- Affiliations
- University of Leicester (GB)
- Baker Heart and Diabetes Institute (AU)
- The Realtime Building, Clonshaugh Business and Technology Park, Shimmer Research Ltd., D17 H262 Dublin, Ireland
- Assessment of Movement Behaviours Group (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE1 7RH, UK
- Corresponding author
- Maylor, Benjamin D.
- ORCID
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2022-12-18
- Volume
- 22
- Issue
- 24
- Pages
- 9984
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC9786909
- OpenAlex
- W4312210946
- Cited by
- 30
- References
- 40
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 8 · 2023: 5
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Apollo (cc-by)
- Apollo
- Funders
- NIHR Applied Research Collaboration East Midlands (ARC EM) (16/41/04, MR/K025090/1)
- National Institute for Health Research Public Health Research programme (16/41/04, MR/K025090/1)
- UK Medical Research Council Lifelong Health and Wellbeing Initiative (16/41/04, MR/K025090/1)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- step counting, wrist-worn accelerometry, concurrent validity, activPAL, moderate-to-vigorous physical activity, physical activity surveillance, physical activity goals
- MeSH terms
- Algorithms, Humans, Wrist, Wrist Joint, Exercise, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.