Using Deep Learning Architectures for Detection and Classification of Diabetic Retinopathy
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Diabetic retinopathy (DR) is a common complication of long-term diabetes, affecting the human eye and potentially leading to permanent blindness. The early detection of DR is crucial for effective treatment, as symptoms often manifest in later stages. The manual grading of retinal images is time-consuming, prone to errors, and lacks patient-friendliness. In this study, we propose two deep learning (DL) architectures, a hybrid network combining VGG16 and XGBoost Classifier, and the DenseNet 121 network, for DR detection and classification. To evaluate the two DL models, we preprocessed a collection of retinal images obtained from the APTOS 2019 Blindness Detection Kaggle Dataset. This dataset exhibits an imbalanced image class distribution, which we addressed through appropriate balancing techniques. The performance of the considered models was assessed in terms of accuracy. The results showed that the hybrid network achieved an accuracy of 79.50%, while the DenseNet 121 model achieved an accuracy of 97.30%. Furthermore, a comparative analysis with existing methods utilizing the same dataset revealed the superior performance of the DenseNet 121 network. The findings of this study demonstrate the potential of DL architectures for the early detection and classification of DR. The superior performance of the DenseNet 121 model highlights its effectiveness in this domain. The implementation of such automated methods can significantly improve the efficiency and accuracy of DR diagnosis, benefiting both healthcare providers and patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saeedi, P., Petersohn, I., Salpea, P., Malanda, B., Karuranga, S., Unwin, N., Colagiuri, S., Guariguata, L., Motala, A. A., Ogurtsova, K., et al. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.107843 · Cited by 10,792 · cited 1×
“In 2019, an estimated 463 million people worldwide were affected by diabetes [2].”
BackgroundThe potential for artificial intelligence in healthcare
Davenport, T., & Kalakota, R. (2019) · Future Healthcare Journal · doi:10.7861/futurehosp.6-2-94 · Cited by 3,800 · cited 1×
“In today’s healthcare systems, the role of artificial intelligence (AI) has become increasingly vital [13].”
BackgroundA deep learning system for detecting diabetic retinopathy across the disease spectrum
Dai, L., Wu, L., Li, H., Cai, C., Wu, Q., Kong, H., Liu, R., Wang, X., Hou, X., Liu, Y., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23458-5 · Cited by 620 · cited 1×
“On the other hand, multiclass classification approaches aim to grade the images into five different categories: Class 0—non DR, Class 1—mild DR, Class 2—moderate DR, Class 3—severe DR, and Class 4—proliferative DR [28,29].”
BackgroundZhao, K., Hu, J., Shao, H., & Hu, J. (2023) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2023.109246 · Cited by 149 · cited 1×
“Authors [46] proposed a federated learning framework that allows multiple users to collaboratively train models locally without sharing sensitive data, enhancing performance and avoiding data privacy concerns.”
Background
Metadata
- Authors
- Mohanty, C., Mahapatra, S., Acharya, B., Kokkoras, F., Gerogiannis, V. C., Karamitsos, I., & Kanavos, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2023-06-19
- Volume
- 23
- Issue
- 12
- Pages
- 5726
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W4381433571
- Cited by
- 212
- References
- 4
- FWCI
- 31.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.