The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Systematic Evaluation of IMU Sensors for Application in Smart Glove System for Remote Monitoring of Hand Differences
Abstract
Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation. However, current clinical methods rely on subjective observations and limited tests. Smart gloves with inertial measurement unit (IMU) sensors have emerged as tools for capturing digit movements, yet their sensor accuracy remains underexplored. This study developed and validated an IMU-based smart glove system for measuring finger joint movements in individuals with hand differences. The glove measured 3D digit rotations and was evaluated against an industrial robotic arm. Tests included rotations around three axes at 1°, 10°, and 90°, simulating extension/flexion, supination/pronation, and abduction/adduction. The IMU sensors demonstrated high accuracy and reliability, with minimal systematic bias and strong positive correlations (p > 0.95 across all tests). Agreement matrices revealed high agreement (<1°) in 24 trials, moderate (1–10°) in 12 trials, and low (>10°) in only 4 trials. The Root Mean Square Error (RMSE) ranged from 1.357 to 5.262 for the 90° tests, 0.094 to 0.538 for the 10° tests, and 0.129 to 0.36 for the 1° tests. Likewise, mean absolute error (MAE) ranged from 0.967 to 4.679 for the 90° tests, 0.073 to 0.386 for the 10° tests, and 0.102 to 0.309 for the 1° tests. The sensor provided precise measurements of digit angles across 0–90° in multiple directions, enabling reliable clinical assessment, remote monitoring, and improved diagnosis, treatment, and rehabilitation for individuals with hand differences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“or are worn on the back of the hand, leaving sensation intact, but are bulky and impractical for users to wear on their own [14,15,16,17].”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [14]
In the citing paper
“The previous literature has used the same IMUs that are in our system (BNO055) to track movements and has characterized the benchtop performance [14,15] as being <4 degrees of absolute angular error in benchtop tests and 8–15 degrees of angular error in on-hand tests [15].”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensor-based and vision-based human activity recognition: A comprehensive survey
Minh Dang, L., Min, K., Wang, H., Jalil Piran, M., Hee Lee, C., & Moon, H. (2020) · Pattern Recognition · doi:10.1016/j.patcog.2020.107561 · Cited by 730
Jones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Research works printed but not linked: 22
- Duruöz, M.T. (2014). Hand Function: A Practical Guide to Assessment, Springer. · doi:10.1007/978-1-4614-9449-2
- Arner, 2008, Hand Function in Cerebral Palsy. Report of 367 Children in a Population-Based Longitudinal Health Care Program, J. Hand Surg., 33, 1337, 10.1016/j.jhsa.2008.02.032 · DOI · Paper page
- Cioncoloni, 2013, Predictors of Long-Term Recovery in Complex Activities of Daily Living before Discharge from the Stroke Unit, NeuroRehabilitation, 33, 217
- Ghițan, A.F., Gheorman, V., Ciurea, M.E., Gheorman, V., Dinescu, V.C., Ciurea, A.M., Militaru, F., Popa, R., Țenea-Cojan, T.Ș., and Udriștoiu, I. (2023). Exploring the Prevalence of PTSD in Hand Trauma: A Comprehensive Study. Brain Sci., 13. · DOI
- Harris, 2007, Paretic Upper-Limb Strength Best Explains Arm Activity in People with Stroke, Phys. Ther., 87, 88, 10.2522/ptj.20060065 · DOI · Paper page
- Cederlund, 2010, Outcome and Clinical Changes in Patients 3, 6, 12 Months after a Severe or Major Hand Injury—Can Sense of Coherence Be an Indicator for Rehabilitation Focus?, BMC Musculoskelet. Disord., 11, 1, 10.1186/1471-2474-11-286 · DOI
- Sayyari, 2022, The Impact of Socioeconomic Status on Hand Injury Severity, Hand Surg. Rehabil., 41, 695, 10.1016/j.hansur.2022.08.010 · doi:10.1016/j.hansur.2022.08.010
- Fabbri, 2021, A Systematic Review of the Psychometric Properties of the Jebsen–Taylor Hand Function Test (JTHFT), Hand Surg. Rehabil., 40, 560, 10.1016/j.hansur.2021.05.004 · DOI
- Sollerman, 1995, Sollerman Hand Function Test: A Standardised Method and Its Use in Tetraplegic Patients, Scand. J. Plast. Reconstr. Surg. Hand Surg., 29, 167, 10.3109/02844319509034334 · DOI · Paper page
- Jebsen, 1969, An Objective and Standardized Test of Hand Function, Arch. Phys. Med. Rehabil., 50, 311
- Al Farid, F., Hashim, N., Abdullah, J., Bhuiyan, M.R., Shahida Mohd Isa, W.N., Uddin, J., Haque, M.A., and Husen, M.N. (2022). A Structured and Methodological Review on Vision-Based Hand Gesture Recognition System. J. Imaging, 8. · DOI
- Pathan, R.K., Biswas, M., Yasmin, S., Khandaker, M.U., Salman, M., and Youssef, A.A.F. (2023). Sign Language Recognition Using the Fusion of Image and Hand Landmarks through Multi-Headed Convolutional Neural Network. Sci. Rep., 13. · DOI
- Qi, 2024, Computer Vision-Based Hand Gesture Recognition for Human-Robot Interaction: A Review, Complex Intell. Syst., 10, 1581, 10.1007/s40747-023-01173-6 · DOI · Paper page
- Gu, C., Lin, W., He, X., Zhang, L., and Zhang, M. (2023). IMU-Based Motion Capture System for Rehabilitation Applications: A Systematic Review. Biomim. Intell. Robot., 3. · DOI
- Caeiro-Rodríguez, M., Otero-González, I., Mikic-Fonte, F.A., and Llamas-Nistal, M. (2021). A Systematic Review of Commercial Smart Gloves: Current Status and Applications. Sensors, 21. · DOI · Paper page
- Oudah, M., Al-Naji, A., and Chahl, J. (2020). Hand Gesture Recognition Based on Computer Vision: A Review of Techniques. J. Imaging, 6. · DOI · Paper page
- Jörg, S., Ye, Y., Mueller, F., Neff, M., and Zordan, V. (2020, January 4–13). Virtual Hands in VR: Motion Capture, Synthesis, and Perception. Proceedings of the SIGGRAPH Asia 2020 Courses, SA 2020, Virtual. · DOI
- Amin, M.S., Rizvi, S.T.H., and Hossain, M.M. (2022). A Comparative Review on Applications of Different Sensors for Sign Language Recognition. J. Imaging, 8. · DOI
- Mennella, C., Alloisio, S., Novellino, A., and Viti, F. (2022). Characteristics and Applications of Technology-Aided Hand Functional Assessment: A Systematic Review. Sensors, 22. · DOI
- Shin, S., Lee, H.J., Chang, W.H., Ko, S.H., Shin, Y.I., and Kim, Y.H. (2022). A Smart Glove Digital System Promotes Restoration of Upper Limb Motor Function and Enhances Cortical Hemodynamic Changes in Subacute Stroke Patients with Mild to Moderate Weakness: A Randomized Controlled Trial. J. Clin. Med., 11. · DOI
- Jung, H.T., Kim, H., Jeong, J., Jeon, B., Ryu, T., and Kim, Y. (2017, January 11–15). Feasibility of Using the RAPAEL Smart Glove in Upper Limb Physical Therapy for Patients after Stroke: A Randomized Controlled Trial. Proceedings of the Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, Jeju, Republic of Korea. · DOI
- Kang, M.G., Yun, S.J., Lee, S.Y., Oh, B.M., Lee, H.H., Lee, S.U., and Seo, H.G. (2020). Effects of Upper-Extremity Rehabilitation Using Smart Glove in Patients with Subacute Stroke: Results of a Prematurely Terminated Multicenter Randomized Controlled Trial. Front. Neurol., 11. · DOI
Cited by
A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System
Oppenheim, T., Schlegel, H., Xie, P. Y., Khokhar, Z., & Khanna, P. (2026) · Sensors · doi:10.3390/s26154795
Metadata
- Authors
- Harrison, A., Jester, A., Mouli, S., Fratini, A., & Jabran, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2024-12-24
- Volume
- 25
- Issue
- 1
- Pages
- 2
- ISSN
- 1424-8220
- Cited by
- 15
- References
- 2
- Language
- en
- Funders
- Engineering and Physical Sciences Research Council (EPSRC) Doctoral Training Partnership grant (EP/R512989/1)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.