The DOI matches its Crossref record; the references it cites are not checked yet.
Optimal Algorithms for Improving Pressure-Sensitive Mat Centre of Pressure Measurements
Abstract
The accurate measurement of human balance is required in numerous analysis and training applications. Force plates are frequently used but are too costly to be suitable for home-based systems such as balance training. A growing body of research and commercial products use Pressure-Sensitive Mats (PSMs) for balance measurement. Low-cost PSMs are constructed with a piezoresistive material and use copper tracks as conductors. However, these lack accuracy, as they often have a low resolution and suffer from noise, non-repeatable effects, and crosstalk. This paper proposes novel algorithms that enable the Centre of Pressure (CoP) to be computed using low-cost PSM designs with significantly higher accuracy than is currently achievable. A mathematical model of a general low-cost PSM was developed and used to select the design of the PSM (track width and placement) that maximises CoP accuracy. These yield new optimal PSM geometries that decrease the mean absolute CoP error from 17.37% to 5.47% for an 8 × 8 sensor layout. Then, knowledge of the footprint was used to further optimise accuracy, showing a decrease in absolute error from 17.37% to 3.93% for an 8 × 8 sensor layout. A third algorithm was derived using models of human movement to further reduce measurement error.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 5
Research works printed but not linked: 46
- Kwon, I.H., Shin, W.S., Choi, K.S., and Lee, M.S. (2024). Effects of Real-Time Feedback Methods on Static Balance Training in Stroke Patients: A Randomized Controlled Trial. Healthcare, 12. · doi:10.3390/healthcare12070767
- Azizi, 2015, Effect of balance training with Biodex Stability System on balance in diabetic neuropathy, Ther. Adv. Endocrinol. Metab., 6, 233, 10.1177/2042018815595566 · DOI
- Hyun, S.J., Lee, J., and Lee, B.H. (2021). The Effects of Sit-to-Stand Training Combined with Real-Time Visual Feedback on Strength, Balance, Gait Ability, and Quality of Life in Patients with Stroke: A Randomized Controlled Trial. Int. J. Environ. Res. Public Health, 18. · DOI
- Ayed, I., Jaume-i Capó, A., Martínez-Bueso, P., Mir, A., and Moyà-Alcover, G. (2021). Balance Measurement Using Microsoft Kinect v2: Towards Remote Evaluation of Patient with the Functional Reach Test. Appl. Sci., 11. · DOI
- Quijoux, 2020, Center of pressure displacement characteristics differentiate fall risk in older people: A systematic review with meta-analysis, Ageing Res. Rev., 62, 101117, 10.1016/j.arr.2020.101117 · DOI
- Onuma, 2020, Measurements of the centre of pressure of individual legs reveal new characteristics of reduced anticipatory postural adjustments during gait initiation in patients with post-stroke hemiplegia, J. Rehabil. Med., 53, 101117
- Celik, 2023, Using the center of pressure movement analysis in evaluating spontaneous movements in infants: A comparative study with general movements assessment, Ital. J. Pediatr., 49, 165, 10.1186/s13052-023-01568-8 · DOI
- Weizman, 2019, Benchmarking study of the forces and centre of pressure derived from a novel smart-insole against an existing pressure measuring insole and force plate, Measurement, 142, 48, 10.1016/j.measurement.2019.03.023 · DOI
- Daroudi, S., Arjmand, N., Mohseni, M., El-Rich, M., and Parnianpour, M. (2024). Evaluation of ground reaction forces and centers of pressure predicted by AnyBody Modeling System during load reaching/handling activities and effects of the prediction errors on model-estimated spinal loads. J. Biomech., 164. · DOI
- Dawson, 2018, Examining the reliability, correlation, and validity of commonly used assessment tools to measure balance, Health Sci. Rep., 1, e98, 10.1002/hsr2.98 · DOI · Paper page
- Bastos-Filho, T.F., de Oliveira Caldeira, E.M., and Frizera-Neto, A. (2020, January 26–30). Center of Mass Estimation Using Kinect and Postural Sway. Proceedings of the XXVII Brazilian Congress on Biomedical Engineering, Vitória, Brazil.
- Chung, 2016, Correlation between accelerometry and clinical balance testing in stroke, J. Phys. Ther. Sci., 28, 2260, 10.1589/jpts.28.2260 · DOI
- Hendrickson, 2014, Relationship between asymmetry of quiet standing balance control and walking post-stroke, Gait Posture, 39, 177, 10.1016/j.gaitpost.2013.06.022 · doi:10.1016/j.gaitpost.2013.06.022
- Goetschius, J., Feger, M.A., Hertel, J., and Hart, J.M. (2018). Validating Center-of-Pressure Balance Measurements Using the MatScan® Pressure Mat. J. Sport Rehabil., 27. · DOI
- Vanegas, 2021, Force-Sensitive Mat for Vertical Jump Measurement to Assess Lower Limb Strength: Validity and Reliability Study, JMIR mHealth uHealth, 9, e27336, 10.2196/27336 · DOI
- Li, W., Sun, C., Yuan, W., Gu, W., Cui, Z., and Chen, W. (2017, January 11–15). Smart mat system with pressure sensor array for unobtrusive sleep monitoring. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju, Republic of Korea. · DOI
- Zhou, 2022, Quali-Mat: Evaluating the Quality of Execution in Body-Weight Exercises with a Pressure Sensitive Sports Mat, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., 6, 89, 10.1145/3534610 · DOI
- Yuan, 2025, Smart Pressure E-Mat for Human Sleeping Posture and Dynamic Activity Recognition, IEEE J. Sel. Areas Sens., 2, 9
- Gao, L., and Lin, Z. (2022). Smart Mat Used for Prevention of Hospital-Acquired Pressure Injuries. arXiv.
- Caggiari, S., Jiang, L., Filingeri, D., and Worsley, P. (2023). Optimization of Spatial and Temporal Configuration of a Pressure Sensing Array to Predict Posture and Mobility in Lying. Sensors, 23. · doi:10.3390/s23156872
- 2024, The Applications of Artificial Intelligence for Assessing Fall Risk: Systematic Review, J. Med. Internet Res., 26, e54934, 10.2196/54934 · DOI
- Brahms, 2022, The acute effects of mental fatigue on balance performance in healthy young and older adults—A systematic review and meta-analysis, Acta Psychol., 225, 103540, 10.1016/j.actpsy.2022.103540 · DOI
- Chen, 2022, Gait balance control after fatigue: Effects of age and cognitive demand, Gait Posture, 95, 129, 10.1016/j.gaitpost.2022.04.020 · DOI
- Fung, A., Lai, E.C., and Lee, B.C. (2018, January 18–21). A new smart balance rehabilitation system technology platform: Development and preliminary assessment of the Smarter Balance System for home-based balance rehabilitation for individuals with Parkinson’s disease. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Honolulu, HI, USA. · doi:10.1109/embc.2018.8512528
- Kiselev, 2015, Implementation of a home-based interactive training system for fall prevention: Requirements and challenges, J. Gerontol. Nurs., 41, 14, 10.3928/00989134-20141201-01 · doi:10.3928/00989134-20141201-01
- Martinez-Cesteros, J., Medrano-Sanchez, C., Plaza-Garcia, I., Igual-Catalan, R., and Albiol-Pérez, S. (2021). A Velostat-Based Pressure-Sensitive Mat for Center-of-Pressure Measurements: A Preliminary Study. Int. J. Environ. Res. Public Health, 18. · DOI · Paper page
- Saenz-Cogollo, J.F., Pau, M., Fraboni, B., and Bonfiglio, A. (2016). Pressure Mapping Mat for Tele-Home Care Applications. Sensors, 16. · doi:10.3390/s16030365
- Fatema, 2024, Investigation of the Long-Term Reliability of a Velostat-Based Flexible Pressure Sensor Array for 210 Days, IEEE Trans. Device Mater. Reliab., 24, 41, 10.1109/TDMR.2023.3340711 · doi:10.1109/tdmr.2023.3340711
- Dzedzickis, A., Sutinys, E., Bucinskas, V., Samukaite-Bubniene, U., Jakstys, B., Ramanavicius, A., and Morkvenaite-Vilkonciene, I. (2020). Polyethylene-Carbon Composite (Velostat®) Based Tactile Sensor. Polymers, 12. · doi:10.3390/polym12122905
- 2019, Circuit Analysis of Matrix-Like Resistor Networks for Eliminating Crosstalk in Pressure Sensitive Mats, IEEE Sens. J., 19, 8027, 10.1109/JSEN.2019.2918592 · DOI
- 2023, Creep and Hysteresis Compensation in Pressure-Sensitive Mats for Improving Center-of-Pressure Measurements, IEEE Sens. J., 23, 29585, 10.1109/JSEN.2023.3324363 · DOI · Paper page
- Fatema, A., Kuriakose, I., Gupta, R., and Hussain, A.M. (2023, January 23–25). Analysis of Interpolation Techniques for a Flexible Sensor Mat for Plantar Pressure Measurement. Proceedings of the 2023 IEEE Applied Sensing Conference (APSCON), Bengaluru, India. · doi:10.1109/apscon56343.2023.10101098
- Müller, S., Seichter, D., and Gross, H.M. (2019, January 18–20). Cross-Talk Compensation in Low-Cost Resistive Pressure Matrix Sensors. Proceedings of the 2019 IEEE International Conference on Mechatronics (ICM), Ilmenau, Germany. · DOI
- Flash, 1985, The coordination of arm movements: An experimentally confirmed mathematical model, J. Neurosci., 5, 1688, 10.1523/JNEUROSCI.05-07-01688.1985 · DOI · Paper page
- Alexander, 1995, Simple Models of Human Movement, Appl. Mech. Rev., 48, 461, 10.1115/1.3005107 · DOI
- Verkerke, 2005, Determining the centre of pressure during walking and running using an instrumented treadmill, J. Biomech., 38, 1881, 10.1016/j.jbiomech.2004.08.015 · DOI
- Park, 2018, Assessment of Weight Shift Direction in Chronic Stroke Patients, Osong Public Health Res. Perspect., 9, 118, 10.24171/j.phrp.2018.9.3.06 · doi:10.24171/j.phrp.2018.9.3.06
- Hung, 2014, Randomized Comparison Trial of Balance Training by Using Exergaming and Conventional Weight-Shift Therapy in Patients With Chronic Stroke, Arch. Phys. Med. Rehabil., 95, 1629, 10.1016/j.apmr.2014.04.029 · DOI
- D’Silva, L.J., Phongsavath, T., Partington, K., Pickle, N.T., Marschner, K., Zehnbauer, T.P., Rossi, M., Skop, K., and Roos, P.E. (2023). A gaming app developed for vestibular rehabilitation improves the accuracy of performance and engagement with exercises. Front. Med., 10. · DOI
- Chang, 2012, Stochastic Nelder–Mead simplex method—A new globally convergent direct search method for simulation optimization, Eur. J. Oper. Res., 220, 684, 10.1016/j.ejor.2012.02.028 · DOI
- Suprapto, S., Setiawan, A., Zakaria, H., Adiprawita, W., and Supartono, B. (2017, January 6–7). Low-Cost Pressure Sensor Matrix Using Velostat. Proceedings of the 2017 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME), Bandung, Indonesia. · doi:10.1109/icici-bme.2017.8537720
- Hopkins, 2020, Examination of the Performance Characteristics of Velostat as an In-Socket Pressure Sensor, IEEE Sens. J., 20, 6992, 10.1109/JSEN.2020.2978431 · DOI
- Betker, 2006, Video Game–Based Exercises for Balance Rehabilitation: A Single-Subject Design, Arch. Phys. Med. Rehabil., 87, 1141, 10.1016/j.apmr.2006.04.010 · DOI · Paper page
- Srinivasan, P., Birchfield, D., Qian, G., and Kidané, A. (2005, January 15–17). A pressure sensing floor for interactive media applications. Proceedings of the 2005 ACM SIGCHI International Conference on Advances in Computer Entertainment Technology, New York, NY, USA. · doi:10.1145/1178477.1178526
- Pierce, R.M., Fedalei, E.A., and Kuchenbecker, K.J. (2014, January 23–26). A wearable device for controlling a robot gripper with fingertip contact, pressure, vibrotactile, and grip force feedback. Proceedings of the 2014 IEEE Haptics Symposium (HAPTICS), Houston, TX, USA. · DOI
- Wulandari, 2023, Center of Pressure Control for Balancing Humanoid Dance Robot Using Load Cell Sensor, Kalman Filter and PID Controller, Control Syst. Optim. Lett., 1, 75, 10.59247/csol.v1i2.22 · doi:10.59247/csol.v1i2.22
Metadata
- Authors
- Bincalar, A. D., Freeman, C., & schraefel, M. C.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2025-02-20
- Volume
- 25
- Issue
- 5
- Pages
- 1283
- ISSN
- 1424-8220
- Cited by
- 5
- Language
- en
- Funders
- UKRI EPSRC studentship (EP/W524621/1)
- UKRI EPSRC (EP/W524621/1)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Algorithms for Improving Pressure-Sensitive Mat Centre of Pressure Measurements. https://app.cochat.ai/papers/10.3390/s25051283
- The paper
- Bincalar, A. D., Freeman, C., & schraefel, M. C. (2025). Optimal Algorithms for Improving Pressure-Sensitive Mat Centre of Pressure Measurements. Sensors. https://doi.org/10.3390/s25051283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.