Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 5

The DOI matches its Crossref record; the references it cites are not checked yet.

Optimal Algorithms for Improving Pressure-Sensitive Mat Centre of Pressure Measurements

Bincalar, Alexander Dawid, Freeman, Chris, schraefel, m.c. · 2025 · Sensors

Abstract

The accurate measurement of human balance is required in numerous analysis and training applications. Force plates are frequently used but are too costly to be suitable for home-based systems such as balance training. A growing body of research and commercial products use Pressure-Sensitive Mats (PSMs) for balance measurement. Low-cost PSMs are constructed with a piezoresistive material and use copper tracks as conductors. However, these lack accuracy, as they often have a low resolution and suffer from noise, non-repeatable effects, and crosstalk. This paper proposes novel algorithms that enable the Centre of Pressure (CoP) to be computed using low-cost PSM designs with significantly higher accuracy than is currently achievable. A mathematical model of a general low-cost PSM was developed and used to select the design of the PSM (track width and placement) that maximises CoP accuracy. These yield new optimal PSM geometries that decrease the mean absolute CoP error from 17.37% to 5.47% for an 8 × 8 sensor layout. Then, knowledge of the footprint was used to further optimise accuracy, showing a decrease in absolute error from 17.37% to 3.93% for an 8 × 8 sensor layout. A third algorithm was derived using models of human movement to further reduce measurement error.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s25051283

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

Cited by 5

Research works printed but not linked: 46

  1. Kwon, I.H., Shin, W.S., Choi, K.S., and Lee, M.S. (2024). Effects of Real-Time Feedback Methods on Static Balance Training in Stroke Patients: A Randomized Controlled Trial. Healthcare, 12. · doi:10.3390/healthcare12070767
  2. Azizi, 2015, Effect of balance training with Biodex Stability System on balance in diabetic neuropathy, Ther. Adv. Endocrinol. Metab., 6, 233, 10.1177/2042018815595566 · DOI
  3. Hyun, S.J., Lee, J., and Lee, B.H. (2021). The Effects of Sit-to-Stand Training Combined with Real-Time Visual Feedback on Strength, Balance, Gait Ability, and Quality of Life in Patients with Stroke: A Randomized Controlled Trial. Int. J. Environ. Res. Public Health, 18. · DOI
  4. Ayed, I., Jaume-i Capó, A., Martínez-Bueso, P., Mir, A., and Moyà-Alcover, G. (2021). Balance Measurement Using Microsoft Kinect v2: Towards Remote Evaluation of Patient with the Functional Reach Test. Appl. Sci., 11. · DOI
  5. Quijoux, 2020, Center of pressure displacement characteristics differentiate fall risk in older people: A systematic review with meta-analysis, Ageing Res. Rev., 62, 101117, 10.1016/j.arr.2020.101117 · DOI
  6. Onuma, 2020, Measurements of the centre of pressure of individual legs reveal new characteristics of reduced anticipatory postural adjustments during gait initiation in patients with post-stroke hemiplegia, J. Rehabil. Med., 53, 101117
  7. Celik, 2023, Using the center of pressure movement analysis in evaluating spontaneous movements in infants: A comparative study with general movements assessment, Ital. J. Pediatr., 49, 165, 10.1186/s13052-023-01568-8 · DOI
  8. Weizman, 2019, Benchmarking study of the forces and centre of pressure derived from a novel smart-insole against an existing pressure measuring insole and force plate, Measurement, 142, 48, 10.1016/j.measurement.2019.03.023 · DOI
  9. Daroudi, S., Arjmand, N., Mohseni, M., El-Rich, M., and Parnianpour, M. (2024). Evaluation of ground reaction forces and centers of pressure predicted by AnyBody Modeling System during load reaching/handling activities and effects of the prediction errors on model-estimated spinal loads. J. Biomech., 164. · DOI
  10. Dawson, 2018, Examining the reliability, correlation, and validity of commonly used assessment tools to measure balance, Health Sci. Rep., 1, e98, 10.1002/hsr2.98 · DOI · Paper page
  11. Bastos-Filho, T.F., de Oliveira Caldeira, E.M., and Frizera-Neto, A. (2020, January 26–30). Center of Mass Estimation Using Kinect and Postural Sway. Proceedings of the XXVII Brazilian Congress on Biomedical Engineering, Vitória, Brazil.
  12. Chung, 2016, Correlation between accelerometry and clinical balance testing in stroke, J. Phys. Ther. Sci., 28, 2260, 10.1589/jpts.28.2260 · DOI
  13. Hendrickson, 2014, Relationship between asymmetry of quiet standing balance control and walking post-stroke, Gait Posture, 39, 177, 10.1016/j.gaitpost.2013.06.022 · doi:10.1016/j.gaitpost.2013.06.022
  14. Goetschius, J., Feger, M.A., Hertel, J., and Hart, J.M. (2018). Validating Center-of-Pressure Balance Measurements Using the MatScan® Pressure Mat. J. Sport Rehabil., 27. · DOI
  15. Vanegas, 2021, Force-Sensitive Mat for Vertical Jump Measurement to Assess Lower Limb Strength: Validity and Reliability Study, JMIR mHealth uHealth, 9, e27336, 10.2196/27336 · DOI
  16. Li, W., Sun, C., Yuan, W., Gu, W., Cui, Z., and Chen, W. (2017, January 11–15). Smart mat system with pressure sensor array for unobtrusive sleep monitoring. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju, Republic of Korea. · DOI
  17. Zhou, 2022, Quali-Mat: Evaluating the Quality of Execution in Body-Weight Exercises with a Pressure Sensitive Sports Mat, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., 6, 89, 10.1145/3534610 · DOI
  18. Yuan, 2025, Smart Pressure E-Mat for Human Sleeping Posture and Dynamic Activity Recognition, IEEE J. Sel. Areas Sens., 2, 9
  19. Gao, L., and Lin, Z. (2022). Smart Mat Used for Prevention of Hospital-Acquired Pressure Injuries. arXiv.
  20. Caggiari, S., Jiang, L., Filingeri, D., and Worsley, P. (2023). Optimization of Spatial and Temporal Configuration of a Pressure Sensing Array to Predict Posture and Mobility in Lying. Sensors, 23. · doi:10.3390/s23156872
  21. 2024, The Applications of Artificial Intelligence for Assessing Fall Risk: Systematic Review, J. Med. Internet Res., 26, e54934, 10.2196/54934 · DOI
  22. Brahms, 2022, The acute effects of mental fatigue on balance performance in healthy young and older adults—A systematic review and meta-analysis, Acta Psychol., 225, 103540, 10.1016/j.actpsy.2022.103540 · DOI
  23. Chen, 2022, Gait balance control after fatigue: Effects of age and cognitive demand, Gait Posture, 95, 129, 10.1016/j.gaitpost.2022.04.020 · DOI
  24. Fung, A., Lai, E.C., and Lee, B.C. (2018, January 18–21). A new smart balance rehabilitation system technology platform: Development and preliminary assessment of the Smarter Balance System for home-based balance rehabilitation for individuals with Parkinson’s disease. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Honolulu, HI, USA. · doi:10.1109/embc.2018.8512528
  25. Kiselev, 2015, Implementation of a home-based interactive training system for fall prevention: Requirements and challenges, J. Gerontol. Nurs., 41, 14, 10.3928/00989134-20141201-01 · doi:10.3928/00989134-20141201-01
  26. Martinez-Cesteros, J., Medrano-Sanchez, C., Plaza-Garcia, I., Igual-Catalan, R., and Albiol-Pérez, S. (2021). A Velostat-Based Pressure-Sensitive Mat for Center-of-Pressure Measurements: A Preliminary Study. Int. J. Environ. Res. Public Health, 18. · DOI · Paper page
  27. Saenz-Cogollo, J.F., Pau, M., Fraboni, B., and Bonfiglio, A. (2016). Pressure Mapping Mat for Tele-Home Care Applications. Sensors, 16. · doi:10.3390/s16030365
  28. Fatema, 2024, Investigation of the Long-Term Reliability of a Velostat-Based Flexible Pressure Sensor Array for 210 Days, IEEE Trans. Device Mater. Reliab., 24, 41, 10.1109/TDMR.2023.3340711 · doi:10.1109/tdmr.2023.3340711
  29. Dzedzickis, A., Sutinys, E., Bucinskas, V., Samukaite-Bubniene, U., Jakstys, B., Ramanavicius, A., and Morkvenaite-Vilkonciene, I. (2020). Polyethylene-Carbon Composite (Velostat®) Based Tactile Sensor. Polymers, 12. · doi:10.3390/polym12122905
  30. 2019, Circuit Analysis of Matrix-Like Resistor Networks for Eliminating Crosstalk in Pressure Sensitive Mats, IEEE Sens. J., 19, 8027, 10.1109/JSEN.2019.2918592 · DOI
  31. 2023, Creep and Hysteresis Compensation in Pressure-Sensitive Mats for Improving Center-of-Pressure Measurements, IEEE Sens. J., 23, 29585, 10.1109/JSEN.2023.3324363 · DOI · Paper page
  32. Fatema, A., Kuriakose, I., Gupta, R., and Hussain, A.M. (2023, January 23–25). Analysis of Interpolation Techniques for a Flexible Sensor Mat for Plantar Pressure Measurement. Proceedings of the 2023 IEEE Applied Sensing Conference (APSCON), Bengaluru, India. · doi:10.1109/apscon56343.2023.10101098
  33. Müller, S., Seichter, D., and Gross, H.M. (2019, January 18–20). Cross-Talk Compensation in Low-Cost Resistive Pressure Matrix Sensors. Proceedings of the 2019 IEEE International Conference on Mechatronics (ICM), Ilmenau, Germany. · DOI
  34. Flash, 1985, The coordination of arm movements: An experimentally confirmed mathematical model, J. Neurosci., 5, 1688, 10.1523/JNEUROSCI.05-07-01688.1985 · DOI · Paper page
  35. Alexander, 1995, Simple Models of Human Movement, Appl. Mech. Rev., 48, 461, 10.1115/1.3005107 · DOI
  36. Verkerke, 2005, Determining the centre of pressure during walking and running using an instrumented treadmill, J. Biomech., 38, 1881, 10.1016/j.jbiomech.2004.08.015 · DOI
  37. Park, 2018, Assessment of Weight Shift Direction in Chronic Stroke Patients, Osong Public Health Res. Perspect., 9, 118, 10.24171/j.phrp.2018.9.3.06 · doi:10.24171/j.phrp.2018.9.3.06
  38. Hung, 2014, Randomized Comparison Trial of Balance Training by Using Exergaming and Conventional Weight-Shift Therapy in Patients With Chronic Stroke, Arch. Phys. Med. Rehabil., 95, 1629, 10.1016/j.apmr.2014.04.029 · DOI
  39. D’Silva, L.J., Phongsavath, T., Partington, K., Pickle, N.T., Marschner, K., Zehnbauer, T.P., Rossi, M., Skop, K., and Roos, P.E. (2023). A gaming app developed for vestibular rehabilitation improves the accuracy of performance and engagement with exercises. Front. Med., 10. · DOI
  40. Chang, 2012, Stochastic Nelder–Mead simplex method—A new globally convergent direct search method for simulation optimization, Eur. J. Oper. Res., 220, 684, 10.1016/j.ejor.2012.02.028 · DOI
  41. Suprapto, S., Setiawan, A., Zakaria, H., Adiprawita, W., and Supartono, B. (2017, January 6–7). Low-Cost Pressure Sensor Matrix Using Velostat. Proceedings of the 2017 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME), Bandung, Indonesia. · doi:10.1109/icici-bme.2017.8537720
  42. Hopkins, 2020, Examination of the Performance Characteristics of Velostat as an In-Socket Pressure Sensor, IEEE Sens. J., 20, 6992, 10.1109/JSEN.2020.2978431 · DOI
  43. Betker, 2006, Video Game–Based Exercises for Balance Rehabilitation: A Single-Subject Design, Arch. Phys. Med. Rehabil., 87, 1141, 10.1016/j.apmr.2006.04.010 · DOI · Paper page
  44. Srinivasan, P., Birchfield, D., Qian, G., and Kidané, A. (2005, January 15–17). A pressure sensing floor for interactive media applications. Proceedings of the 2005 ACM SIGCHI International Conference on Advances in Computer Entertainment Technology, New York, NY, USA. · doi:10.1145/1178477.1178526
  45. Pierce, R.M., Fedalei, E.A., and Kuchenbecker, K.J. (2014, January 23–26). A wearable device for controlling a robot gripper with fingertip contact, pressure, vibrotactile, and grip force feedback. Proceedings of the 2014 IEEE Haptics Symposium (HAPTICS), Houston, TX, USA. · DOI
  46. Wulandari, 2023, Center of Pressure Control for Balancing Humanoid Dance Robot Using Load Cell Sensor, Kalman Filter and PID Controller, Control Syst. Optim. Lett., 1, 75, 10.59247/csol.v1i2.22 · doi:10.59247/csol.v1i2.22

Metadata

Authors
Bincalar, A. D., Freeman, C., & schraefel, M. C.
Venue
Sensors
Publisher
MDPI AG
Published
2025-02-20
Volume
25
Issue
5
Pages
1283
ISSN
1424-8220
Cited by
5
Language
en
Funders
  • UKRI EPSRC studentship (EP/W524621/1)
  • UKRI EPSRC (EP/W524621/1)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimal Algorithms for Improving Pressure-Sensitive Mat Centre of Pressure Measurements. https://app.cochat.ai/papers/10.3390/s25051283
The paper
Bincalar, A. D., Freeman, C., & schraefel, M. C. (2025). Optimal Algorithms for Improving Pressure-Sensitive Mat Centre of Pressure Measurements. Sensors. https://doi.org/10.3390/s25051283

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.