Safe Fall: Use of Predictive Modeling and Machine Vision Techniques for Fall Analysis and Fall Quality
Open accessThe DOI matches its Crossref record; 14 of the 20 references it cites were found in a registry or an index, and 4 are not checked yet; 34 of the 49 sources its claims cite were checked for support.
Abstract
Falls are a leading cause of paediatric injuries, yet school-based prevention relies heavily on subjective observation rather than objective biomechanical assessment. This paper introduces the Safe Fall framework, integrating a judo-inspired educational programme with an occlusion-robust computer vision pipeline to quantify safe falling strategies. We analysed video recordings of 285 schoolchildren using a multi-stage architecture combining YOLOv8 for detection, SAM 2 for segmentation, and MMPose for skeletal tracking. The intervention yielded significant improvements in 60% of kinematic metrics (p<0.05), most notably a +61.4% increase in descent rate and expanded rolling ranges, indicating a shift from hazardous “freezing” behaviours to controlled energy dissipation. Unsupervised clustering confirmed a migration of students towards safe motor profiles, while a Random Forest classifier achieved an accuracy of 98.3% and an AUC of 0.998 in distinguishing fall quality. These findings demonstrate that integrating pedagogical training with automated vision modelling provides a scalable and evidence-based approach for reducing injury risk in real-world school environments.
Verified 2026-11-22 · 4 references not checked yet
Overview
CoChat Summary
## TL;DR
Safe Fall combines a judo-inspired school intervention with a computer vision pipeline to objectively measure how children fall, using video from 285 schoolchildren. The program was associated with significant biomechanical improvements, and a Random Forest model distinguished safe from hazardous falls with 98.3% accuracy and an AUC of 0.998.
## Key findings
- In the pre/post comparison, 9 of 15 biomechanical metrics (60%) showed statistically significant differences (p < 0.05), indicating a shift from uncontrolled falls to managed backward rolling.
- The intervention increased Avg. Descent Rate by +61.4% and showed significant increases in Movement Range X (p < 10−4) and Movement Range Y (p = 0.0007).
- Unsupervised clustering on 415 fall observations identified 3 motor profiles; post-test participants were over-represented in the Controlled Protective Strategy cluster (n = 300), while pre-test participants predominated in the Chaotic (n = 20) and Passive/Freezing (n = 95) clusters.
- For fall-quality classification, the Random Forest model achieved 98.3% accuracy, F1 = 0.983, and AUC = 0.998 on a subject-independent 5-fold cross-validation.
## Methods
- Design: Quasi-experimental pre-test–post-test study of a six-week judo/Ukemi instructional unit in primary schools; fall quality was also modeled as a supervised binary classification problem.
- Sample and data: 285 schoolchildren aged 6–12 years (mean 9.4 ± 1.2), from five primary schools; video recorded at 60 fps and 1920×1080 resolution, with n = 130 post-intervention recordings and 415 total fall observations for some analyses.
- Analysis: Computer vision pipeline used YOLOv8 for detection, SAM 2 for segmentation, Norfair for tracking, and MMPose/RTMPose for pose estimation; extracted 15 kinematic descriptors and 313 frame-level features; statistics used Mann–Whitney U, k-means clustering with PCA, and machine learning with Random Forest, LSTM, ST-GCN, and subject-independent 5-fold cross-validation.
## Limitations
- The paper states that the sample was restricted to school-aged children (6–12 years), so generalization to other age groups was not assessed.
- It states that some fine-grained variables, especially exact cervical angles and complex rolling phases, remain hard to estimate reliably from 2D pose data because of severe self-occlusion.
- The paper notes the quasi-experimental design and lack of a randomized control group as limitations, meaning confounding from maturation or familiarity with the test environment cannot be ruled out.
- Evident from the text: post-test data were available for only 130 of 285 children, so attrition may affect comparability between pre- and post-intervention groups.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
25 Valid · 9 Not valid · 13 Not checked · 106 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Current validation relies on the INFOSECA observation scale, a clinical instrument that evaluates five biomechanical criteria (e.g., head protection, trunk rolling) [2].”
§ Safe Fall: Use of Predictive Modeling and Machine Vision Techniques for Fall Analysis and Fall Quality > 1. Introduction
What the sources say
- Partly supportedcites [2] Del Castillo-Andrés Ó. Toronjo-Hornillo L. Toronjo-Urquiza L. Effects of Fall Training Program on Automatization of Safe Motor Responses during Backwards Falls in School-Age Children Int. J. Environ. Res. Public Health 2019 16 4078 10.3390/ijerph16214078 31652771 PMC6862607 sourceExperimental — accuracy not yet measured
Section 2.5 (page unavailable) says the study used an observation scale to score fall responses in five body parts, including head and back. It does not describe the scale as a clinical instrument or establish that current validation relies on it; its back criterion is landing on a flat back, not trunk rolling. (LLM, conf=0.88)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“A rapid transition from 0∘ (vertical) to 90∘ (horizontal) served as a primary fall trigger [6].”
§ Safe Fall: Use of Predictive Modeling and Machine Vision Techniques for Fall Analysis and Fall Quality > 2. Materials and Methods > 2.3. Feature Extraction and Scoring System
What the sources say
- Partly supportedcites [6] Zobi M. Bolzani L. Tabii Y. Oulad Haj Thami R. Robust 3D Skeletal Joint Fall Detection in Occluded and Rotated Views Using Data Augmentation and Inference–Time Aggregation Sensors 2025 25 6783 10.3390/s25216783 41229006 PMC12609388 sourceExperimental — accuracy not yet measured
The Methodology (§3.3; page unavailable) identifies rapid changes in vertical displacement as fall indicators. Related Work (§2; page unavailable) describes trunk angle as a verification measure in an earlier system, but says that system first checks an accelerometer threshold. Neither passage supports a rapid 0°-to-90° trunk transition as the primary fall trigger. (LLM, conf=0.82)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“While clinically valid, manual observation is subjective, labour-intensive, and unscalable for large student populations.”
§ Safe Fall: Use of Predictive Modeling and Machine Vision Techniques for Fall Analysis and Fall Quality > 1. Introduction
What the sources say
- Partly supportedcites [2] Del Castillo-Andrés Ó. Toronjo-Hornillo L. Toronjo-Urquiza L. Effects of Fall Training Program on Automatization of Safe Motor Responses during Backwards Falls in School-Age Children Int. J. Environ. Res. Public Health 2019 16 4078 10.3390/ijerph16214078 31652771 PMC6862607 sourceExperimental — accuracy not yet measured
Methods §2.5 describes an observer scoring children’s fall responses with an observation scale, so the paper supports the use of manual observation in this school-based study. It does not say that school-based prevention relies heavily on that approach or assess whether observation is subjective, labour-intensive, or unscalable compared with biomechanical assessment. (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Standard pose estimation frameworks, such as OpenPose or MediaPipe, frequently suffer from tracking degradation in these high-velocity, non-linear scenarios, resulting in lost keypoints and identity switching [5,6].”
§ Safe Fall: Use of Predictive Modeling and Machine Vision Techniques for Fall Analysis and Fall Quality > 1. Introduction
What the sources say
- Partly supportedcites [5] Chung J.L. Ong L.Y. Leow M.C. Comparative Analysis of Skeleton-Based Human Pose Estimation Future Internet 2022 14 380 10.3390/fi14120380 sourceExperimental — accuracy not yet measured
The Discussion (p. 15) reports that OpenPose was weak at detecting keypoints in continuous video frames, and the Image Dataset results (p. 8) report poor keypoint-detection performance for MediaPipe Pose. But the Discussion says MediaPipe Pose performed well on video, and the cited passages do not establish frequent degradation in high-velocity, non-linear motion or identity switching. (LLM, conf=0.86)
- Could not verifycites [6] Zobi M. Bolzani L. Tabii Y. Oulad Haj Thami R. Robust 3D Skeletal Joint Fall Detection in Occluded and Rotated Views Using Data Augmentation and Inference–Time Aggregation Sensors 2025 25 6783 10.3390/s25216783 41229006 PMC12609388 sourceExperimental — accuracy not yet measured
Section 3.2 (page unavailable) discusses OpenPose’s computational cost and the choice of MMPose, but not tracking failures during high-velocity, non-linear motion. Searches for lost keypoints, identity switching, and fast-motion tracking found no passage addressing those claims for OpenPose or MediaPipe. (LLM, conf=0.73)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“An AR>1.0 typically indicated a transition to a lying state, distinguishing falls from daily activities like sitting [14].”
§ Safe Fall: Use of Predictive Modeling and Machine Vision Techniques for Fall Analysis and Fall Quality > 2. Materials and Methods > 2.3. Feature Extraction and Scoring System
What the sources say
- Partly supportedcites [14] Wang Y. Deng T. Enhancing elderly care: Efficient and reliable real-time fall detection algorithm Digit. Health 2024 10 10.1177/20552076241233690 38384367 PMC10880526 sourceExperimental — accuracy not yet measured
The Methodology sections on skeleton-based feature engineering and cascaded random forests (page unavailable) identify aspect ratio as a fall-related feature and describe a classifier that distinguishes lying, non-lying, and temporary poses. They do not state that AR>1.0 indicates a transition to lying or that this threshold distinguishes falls from sitting. (LLM, conf=0.86)
hedgedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
- Partly supported
78 more claims · 12 with their cited sources checked
Create a free account to see all 153 claims and to verify the 5 references still open.
- It may state two separate claims as one. 56
- Probably not a substantial claim. 17
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538 · cited 1×
“We prioritised Random Forest (RF) [15] as our primary baseline due to its high interpretability and resistance to overfitting in high-dimensional feature spaces.”
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318 · cited 2×
“The Multilayer Perceptron (MLP) provided a competitive neural baseline (93.2%), but the slight performance gap suggests that for structured tabular kinematic data, the hierarchical decision capability of trees is more sample-efficient than fully connected layers [17].”
InfluentialRTMPose: Real-Time Multi-Person Pose Estimation based on MMPosePreprint
Jiang, T., Lu, P., Zhang, L., Ma, N., Han, R., Lyu, C., Li, Y., & Chen, K. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2303.07399 · Cited by 757
SisFall: A Fall and Movement Dataset
Sucerquia, A., López, J., & Vargas-Bonilla, J. (2017) · Sensors · doi:10.3390/s17010198 · Cited by 530 · cited 3×
“Furthermore, unlike datasets such as SisFall [10] that rely on invasive wearable sensors (IMUs), which may alter motor behaviour, we employed a non-intrusive computer vision approach.”
InfluentialSAM 2: Segment Anything in Images and Videos
Ravi, N., Gabeur, V., Hu, Y.-T., Hu, R., Ryali, C., Ma, T., Khedr, H., Rädle, R., Rolland, C., Gustafson, L., et al. (2024) · arXiv · doi:10.48550/arxiv.2408.00714 · Cited by 300
Online Fall Detection Using Recurrent Neural Networks on Smart Wearable Devices
Musci, M., De Martini, D., Blago, N., Facchinetti, T., & Piastra, M. (2021) · IEEE Transactions on Emerging Topics in Computing · doi:10.1109/tetc.2020.3027454 · Cited by 128
Comparative Analysis of Skeleton-Based Human Pose Estimation
Chung, J.-L., Ong, L.-Y., & Leow, M.-C. (2022) · Future Internet · doi:10.3390/fi14120380 · Cited by 124 · cited 1×
“Standard pose estimation frameworks, such as OpenPose or MediaPipe, frequently suffer from tracking degradation in these high-velocity, non-linear scenarios, resulting in lost keypoints and identity switching [5,6].”
Safe landing strategies during a fall: Systematic review and meta-analysis
Moon, Y., & Sosnoff, J. J. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.08.460 · Cited by 79
Dataset for human fall recognition in an uncontrolled environment
Guerrero, J. C. E., España, E. M., Añasco, M. M., & Lopera, J. E. P. (2022) · Data in Brief · doi:10.1016/j.dib.2022.108610 · Cited by 45
Enhancing elderly care: Efficient and reliable real-time fall detection algorithm
Wang, Y., & Deng, T. (2024) · DIGITAL HEALTH · doi:10.1177/20552076241233690 · Cited by 28 · cited 7×
“An AR > 1.0 typically indicated a transition to a lying state, distinguishing falls from daily activities like sitting [14].”
Influential
Metadata
- Authors
- DelCastillo-Andrés, O., Fernández-García, R., Pastor-Vicedo, J. C., Lira, M. A., Campos-Mesa, M. C., Castañeda-Vázquez, C., Genovesi, E., Krstulović, S., Kuvačić, G., Morvay-Sey, K., & Sánchez-Reolid, R.
- Affiliations
- Department of Physical Education and Sport, Area of Didactics of Body Expression, Faculty of Educational Sciences, University of Seville, 41009 Seville, Spain
- Department of Electronic Engineering, Universitat Politècnica de Catalunya, 08222 Terrassa, Spain
- Facultad de Educación de Albacete, Universidad de Castilla-La Mancha, 02071 Albacete, Spain
- Universitat de Barcelona (ES)
- University of Milan (IT)
- University of Split (HR)
- University of Pecs (HU)
- University of Castilla-La Mancha (ES)
- Corresponding author
- Sánchez-Reolid, R.
- ORCID
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2026-04-17
- Volume
- 26
- Issue
- 8
- Pages
- 2491
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC13120547
- OpenAlex
- W7154695172
- Cited by
- 1
- References
- 20
- Citations by year
- 2026: 1
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- RUIdeRA - Institutional University Repository (University of Castilla-La Mancha) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Deposito de Investigacion Universidad de Sevilla (University of Seville) (submittedVersion, cc-by)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, cc-by-nc-nd)
- Funders
- European Judo Union (PRJ202405200)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Human Pose and Action Recognition
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- fall analysis, fall prevention, elementary school students, skeleton tracking, injury risk reduction
- MeSH terms
- Accidental Falls, Machine Learning, Random Forest, Predictive Learning Models, Biomechanical Phenomena, Child, Female, Humans, Video Recording
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.