The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Textile Pressure Sensor Made of Flexible Plastic Optical Fibers
Open accessAbstract
In this paper we report the successful development of pressure sensitive textile prototypes based on flexible optical fibers technology. Our approach is based on thermoplastic silicone fibers, which can be integrated into woven textiles. As soon as pressure at a certain area of the textile is applied to these fibers they change their cross section reversibly, due to their elastomeric character, and a simultaneous change in transmitted light intensity can be detected. We have successfully manufactured two different woven samples with fibers of 0.51 and 0.98 mm diameter in warp and weft direction, forming a pressure sensitive matrix. Determining their physical behavior when a force is applied shows that pressure measurements are feasible. Their usable working range is between 0 and 30 N. Small drifts in the range of 0.2 to 4.6%, over 25 load cycles, could be measured. Finally, a sensor array of 2 x 2 optical fibers was tested for sensitivity, spatial resolution and light coupling between fibers at intersections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Yetisen, A. K., Qu, H., Manbachi, A., Butt, H., Dokmeci, M. R., Hinestroza, J. P., Skorobogatiy, M., Khademhosseini, A., & Yun, S. H. (2016) · ACS Nano · doi:10.1021/acsnano.5b08176 · Cited by 752
Applications of nanotechnology in smart textile industry: A critical review
Shah, M. A., Pirzada, B. M., Price, G., Shibiru, A. L., & Qurashi, A. (2022) · Journal of Advanced Research · doi:10.1016/j.jare.2022.01.008 · Cited by 412
Highly Sensitive Pressure Sensor Based on Bioinspired Porous Structure for Real‐Time Tactile Sensing
Kang, S., Lee, J., Lee, S., Kim, S., Kim, J., Algadi, H., Al‐Sayari, S., Kim, D., Kim, D., & Lee, T. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201600356 · Cited by 363
Metadata
- Authors
- Rothmaier, M., Luong, M. P., & Clemens, F.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2008-07-25
- Volume
- 8
- Issue
- 7
- Pages
- 4318-4329
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2149389784
- Cited by
- 202
- References
- 1
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Textile Pressure Sensor Made of Flexible Plastic Optical Fibers. https://app.cochat.ai/papers/10.3390/s8074318
- The paper
- Rothmaier, M., Luong, M. P., & Clemens, F. (2008). Textile Pressure Sensor Made of Flexible Plastic Optical Fibers. Sensors. https://doi.org/10.3390/s8074318
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.