The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Highly Sensitive Pressure Sensor Based on Bioinspired Porous Structure for Real‐Time Tactile Sensing
Abstract
A flexible pressure sensor with high performances is one of the promising candidates for achieving electronic skins (E‐skin) related to various applications such as wearable devices, health monitoring systems, and artificial robot arms. The sensitive response for external mechanical stimulation is fundamentally required to develop the E‐skin which imitates the function of human skin. The performance of capacitive pressure sensors can be improved using morphologies and structures occurring in nature. In this work, highly sensitive capacitive pressure sensors based on a porous structure of polydimethylsiloxane (PDMS) thin film, inspired on the natural multilayered porous structures seen in mushrooms, diatoms, and spongia offilinalis, have been developed and evaluated. A bioinspired porous dielectric layer is used, resulting in high‐performance pressure sensors with high sensitivity (0.63 kPa−1), high stability over 10 000 cycles, fast response and relaxation times, and extremely low‐pressure detection of 2.42 Pa. Additionally, the resulting pressure sensors are demonstrated to fabricate multipixel arrays, thus achieving successful real‐time tactile sensing of various touch shapes. The developed high‐performance flexible pressure sensors may open new opportunities for innovative applications in advanced human‐machine interface systems, robotic sensory systems, and various wearable health monitoring devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Self-citationAn ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Tactile Sensing—From Humans to Humanoids
Dahiya, R. S., Metta, G., Valle, M., & Sandini, G. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2033627 · Cited by 1,851
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
A Rubberlike Stretchable Active Matrix Using Elastic Conductors
Sekitani, T., Noguchi, Y., Hata, K., Fukushima, T., Aida, T., & Someya, T. (2008) · Science · doi:10.1126/science.1160309 · Cited by 1,366
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Cited by
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Microengineering Pressure Sensor Active Layers for Improved Performance
Ruth, S. R. A., Feig, V. R., Tran, H., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003491 · Cited by 538
Ionic Skin with Biomimetic Dielectric Layer Templated from Calathea Zebrine Leaf
Qiu, Z., Wan, Y., Zhou, W., Yang, J., Yang, J., Huang, J., Zhang, J., Liu, Q., Huang, S., Bai, N., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201802343 · Cited by 319
Yuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180
Metadata
- Authors
- Kang, S., Lee, J., Lee, S., Kim, S., Kim, J., Algadi, H., Al‐Sayari, S., Kim, D., Kim, D., & Lee, T.
- Venue
- Advanced Electronic Materials
- Publisher
- Wiley
- Published
- 2016-11-07
- Volume
- 2
- Issue
- 12
- ISSN
- 2199-160X (ISSN-L)
- OpenAlex
- W2549908717
- Cited by
- 363
- References
- 38
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Pressure Sensor Based on Bioinspired Porous Structure for Real‐Time Tactile Sensing. https://app.cochat.ai/papers/10.1002/aelm.201600356
- The paper
- Kang, S., Lee, J., Lee, S., Kim, S., Kim, J., Algadi, H., Al‐Sayari, S., Kim, D., Kim, D., & Lee, T. (2016). Highly Sensitive Pressure Sensor Based on Bioinspired Porous Structure for Real‐Time Tactile Sensing. Advanced Electronic Materials. https://doi.org/10.1002/aelm.201600356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.