Effects of Inertial Measurement Unit Location on the Validity of Vertical Acceleration Time-Series Data and Jump Height in Countermovement Jumping
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Inertial measurement units (IMUs) are an example of practical technology for measuring countermovement jump (CMJ) performance, but there is a need to enhance their validity. One potential strategy to achieve this is advancing the literature on IMU placement. Many studies opt to position a single IMU on anatomical landmarks rather than determining placement based on anthropometric principles, despite the knowledge that linear mechanics act through the segmental centers of mass of the human body. The purpose of this study was to evaluate the impact of positioning IMU sensors to approximate the trunk and lower-extremity segmental centers of mass on the validity of vertical acceleration measurements and jump height (JH) estimation during CMJs. Thirty young adults (female n = 10, 21.3 (3.8) years, 166.1 (4.1) cm, 67.6 (11.3) kg; male n = 20, 22.0 (2.6) years, 179.2 (6.4) cm, 83.5 (17.1) kg) from a university setting participated in the study. Seven IMUs were positioned at the approximate centers of mass of the trunk, thighs, shanks, and feet. Using data from these sensors, 15 whole-body center of mass models were developed, including 1-, 2-, 3-, and 4-segment configurations derived from the trunk and three lower-body segments. The root mean square error (RMSE) of vertical acceleration was calculated for each IMU model by comparing its data against vertical acceleration measurements obtained from a force platform. JH estimates were calculated using the take-off velocity method and compared across IMU models and the force platform to evaluate for systematic bias. RMSE and JH values from the best-performing 1-, 2-, 3-, and 4-segment IMU models were analyzed for main effects using one-way analyses of variance. The best performing 2-segment (trunk and shanks; RMSE = 2.1 ± 1.3 m × s−2) and 3-segment (trunk, thighs, and feet; RMSE = 2.0 ± 1.2 m × s−2) IMU models returned significantly lower RMSE values compared to the 1- segment (trunk; RMSE = 3.0 ± 1.4 m × s−2) model (p = 0.021–0.041). No systematic bias was detected between the JH estimates derived from the best-performing IMU models and those obtained from the force platform (p = 0.91–0.99). Positioning multiple IMU sensors to approximate segmental centers of mass significantly improved the validity of vertical acceleration time-series data from CMJs. The findings highlight the importance of anthropometric-based IMU placement for enhancing measurement accuracy without introducing systematic bias.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By fusing data from these components, IMUs can estimate 2D or 3D linear acceleration and angular velocity relative to a global reference frame 103 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [103]
In the citing paper
“Joint motion is highly complex due to multiple degrees of freedom in major joints, making accurate motion capture and analysis more challenging 103 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [103]
Citations
Cites
Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters
de Leva, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00178-6 · Cited by 2,958 · cited 6×
“After signal alignment, the vertical acceleration signals from the IMUs were combined to create 1, 2-, 3-, and 4-segment IMU models of the WBCoM, using the segment-mass weighting coefficients from de Leva (Tables 2–5) [26,27].”
InfluentialReliability and Factorial Validity of Squat and Countermovement Jump Tests
Markovic, G., Dizdar, D., Jukic, I., & Cardinale, M. (2004) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200408000-00028 · Cited by 1,097
Accuracy of human motion capture systems for sport applications; state‐of‐the‐art review
van der Kruk, E., & Reijne, M. M. (2018) · European Journal of Sport Science · doi:10.1080/17461391.2018.1463397 · Cited by 522 · cited 1×
“Numerous devices are available for measuring CMJ performance, with force platform dynamometry and optical motion capture regarded as criterion tools in laboratory settings [8–10].”
Evaluation of Four Vertical Jump Tests: Methodology, Reliability, Validity, and Accuracy
Aragón, L. F. (2000) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0404_2 · Cited by 272 · cited 1×
“Numerous devices are available for measuring CMJ performance, with force platform dynamometry and optical motion capture regarded as criterion tools in laboratory settings [8–10].”
Validity of vertical jump measurement devices
Buckthorpe, M., Morris, J., & Folland, J. P. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2011.624539 · Cited by 198
Xu, J., Turner, A. N., Comfort, P., Harry, J. R., McMahon, J. J., Chavda, S., & Bishop, C. J. (2023) · Sports Medicine · doi:10.1007/s40279-023-01828-x · Cited by 177 · cited 1×
“Several practical technologies for measuring CMJ performance are widely used in the field, offering advantages over force platforms and optical motion capture [11].”
Countermovement jump performance assessment using a wearable 3D inertial measurement unit
Picerno, P., Camomilla, V., & Capranica, L. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2010.523089 · Cited by 124
Validation of an inertial measurement unit for the measurement of jump count and height
MacDonald, K., Bahr, R., Baltich, J., Whittaker, J. L., & Meeuwisse, W. H. (2016) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2016.12.001 · Cited by 102
Pavei, G., Seminati, E., Cazzola, D., & Minetti, A. E. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00129 · Cited by 101 · cited 1×
“Despite these limitations, the model remains widely used and effectively estimates the 3D trajectory of the WBCoM [28].”
Skazalski, C., Whiteley, R. J., Hansen, C., & Bahr, R. (2018) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13052 · Cited by 91
Holsgaard‐Larsen, A., Jensen, C., MORTENSEN, N. H. M., & Aagaard, P. (2013) · The Knee · doi:10.1016/j.knee.2013.06.002 · Cited by 81 · cited 1×
“It serves as a reliable measure of lower-extremity stretch-shortening cycle (SSC) function and mechanical power [3,4], a method for monitoring neuromuscular fatigue [5], and a benchmark for tracking post-injury rehabilitation progress [6,7].”
Lesinski, M., Muehlbauer, T., & Granacher, U. (2016) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-016-0061-x · Cited by 57 · cited 1×
“A majority of studies have investigated the validity of estimating CMJ JH using a single IMU, reporting errors ranging from 3% to 12% when compared to force plates or optical motion capture systems [14–19].”
Chaaban, C. R., Berry, N. T., Armitano‐Lago, C., Kiefer, A. W., Mazzoleni, M. J., & Padua, D. A. (2021) · Sensors · doi:10.3390/s21134383 · Cited by 51 · cited 2×
“%) to those observed in single-IMU estimations of JH using the flight time method [24,25].”
InfluentialEffect of Landing Posture on Jump Height Calculated from Flight Time
Yamashita, D., Murata, M., & Inaba, Y. (2020) · Applied Sciences · doi:10.3390/app10030776 · Cited by 42 · cited 1×
“For instance, variations in posture during takeoff and landing may significantly overestimate CMJ height [12].”
Jump height from inertial recordings: A tutorial for a sports scientist
Rantalainen, T., Finni, T. J., & Walker, S. (2019) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13546 · Cited by 37
Pérez‐Castilla, A., Fernandes, J. F. T., Rojas, F. J., & García‐Ramos, A. (2021) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2021.1872578 · Cited by 37
Souissi, S., Wong, D. P., Dellal, A., Croisier, J., Ellouze, Z., & Chamari, K. (2011) · Europe PMC (PubMed Central) · Cited by 36
Validation of an inertial measurement unit to determine countermovement jump height
Petersen, E. T., Jørgensen, P. B., Mechlenburg, I., & Sørensen, H. (2018) · Asia-Pacific Journal of Sports Medicine Arthroscopy Rehabilitation and Technology · doi:10.1016/j.asmart.2018.09.002 · Cited by 36 · cited 1×
“It serves as a reliable measure of lower-extremity stretch-shortening cycle (SSC) function and mechanical power [3,4], a method for monitoring neuromuscular fatigue [5], and a benchmark for tracking post-injury rehabilitation progress [6,7].”
Physiologic Effects of Caffeine on Crosscountry Runners
Birnbaum, L. J., & Herbst, J. D. (2004) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200408000-00012 · Cited by 32
Can IMU Provide an Accurate Vertical Jump Height Estimate?
Marković, S., Dopsaj, M., Tomažič, S., Kos, A., Nedeljković, A., & Umek, A. (2021) · Applied Sciences · doi:10.3390/app112412025 · Cited by 27
Fathian, R., Khandan, A., Chiu, L. Z. F., & Rouhani, H. (2022) · Sports Biomechanics · doi:10.1080/14763141.2022.2032296 · Cited by 23 · cited 2×
“…small systematic bias observed in this investigation is consistent with biases reported in recent research using the flight time method [20–22, 33 ], systematic bias When RMSE is expressed as a percentage of the average vertical acceleration, the top-performing IMU models showed RMSE…”
Louder, T. J., Thompson, B. J., & Bressel, E. (2021) · Sports · doi:10.3390/sports9070097 · Cited by 21 · cited 1×
“The take-off point was determined using a rate of GRF development method previously described [26,32].”
Self-citationMiranda-Oliveira, P., Branco, M., & Fernandes, O. (2022) · Sensors · doi:10.3390/s22197186 · Cited by 19 · cited 2×
“…relatively small systematic bias observed in this investigation is consistent with biases reported in recent research using the flight time method [20–22, 33 ], systematic bias When RMSE is expressed as a percentage of the average vertical acceleration, the top-performing IMU models showed RMSE…”
A method for monitoring reactive strength index
Patterson, M., & Caulfield, B. (2010) · Procedia Engineering · doi:10.1016/j.proeng.2010.04.120 · Cited by 18 · cited 1×
“It serves as a reliable measure of lower-extremity stretch-shortening cycle (SSC) function and mechanical power [3,4], a method for monitoring neuromuscular fatigue [5], and a benchmark for tracking post-injury rehabilitation progress [6,7].”
Determining jumping performance from a single body-worn accelerometer using machine learning
White, M., Bezodis, N. E., Neville, J., Summers, H. D., & Rees, P. C. T. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263846 · Cited by 17 · cited 2×
“For example, White et al. [24] reported a 5.1% error in measuring peak power during CMJ using a single-IMU setup and machine learning compared to a force platform criterion.”
InfluentialA Mixed-Methods Approach to Evaluating the Internal Validity of the Reactive Strength Index
Louder, T. J., Thompson, B. J., Banks, N. F., & Bressel, E. (2019) · Sports · doi:10.3390/sports7070157 · Cited by 15 · cited 1×
“Additionally, there are inherent concerns regarding the internal validity of estimating JH from flight time, particularly when making comparisons across individuals [23].”
Self-citationManor, J., Bunn, J. A., & Bohannon, R. W. (2018) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0000000000000205 · Cited by 12
A Wearable Inertial Sensor Unit for Jump Diagnosis in Multiple Athletes
Schmidt, M., Jaitner, T., Nolte, K., Rheinländer, C. C., Wille, S., & Wehn, N. (2014) · International Conference on Sport Sciences Research and Technology Support (icSPORTS) · doi:10.5220/0005145902160220 · Cited by 8 · cited 1×
“Among these, the countermovement jump (CMJ) is a widely adopted performance test across multiple disciplines [1,2].”
Villa, G., Bonfiglio, A., Galli, M., & Cimolin, V. (2024) · Sensors · doi:10.3390/s24247877 · Cited by 8
Amin Mohammadian, M., Mozayyany, H., Bagheri Koudakani, S., & Maloney, S. J. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112338 · Cited by 5 · cited 1×
“A majority of studies have investigated the validity of estimating CMJ JH using a single IMU, reporting errors ranging from 3% to 12% when compared to force plates or optical motion capture systems [14–19].”
Villa, G., Cerfoglio, S., Galli, M., & Cimolin, V. (2024) · IEEE International Workshop on Sport, Technology and Research (STAR) · doi:10.1109/star62027.2024.10635965 · Cited by 4 · cited 1×
“…small systematic bias observed in this investigation is consistent with biases reported in recent research using the flight time method [20–22, 33 ], systematic bias When RMSE is expressed as a percentage of the average vertical acceleration, the top-performing IMU models showed RMSE values…”
Villa, G., Bonfiglio, A., Galli, M., et al. (2024) · Preprints.org · doi:10.20944/preprints202410.1153.v1 · Cited by 3
Althouse, D. (2022) · Digital Commons - USU (Utah State University) · doi:10.26076/88a9-d1c3 · Cited by 3
Self-citationAssessing the validity of an instrumented medicine ball for measuring throw speed
Trunt, A., Reed, C., & MacFadden, L. N. (2023) · Sports Engineering · doi:10.1007/s12283-023-00413-9 · Cited by 2 · cited 2×
“For each IMU, angular velocity and acceleration data were fused using an error-state Kalman filter [13], which provided an estimate of vertical acceleration aligned with the global reference frame [26].”
InfluentialMohammadian, M. A., Mozayyany, H., Koudakani, S. B., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4668096 · Cited by 1
Research works printed but not linked: 1
- Winter, D. (1990). Biomechanics and Motor Control of Human Movement, John Wiley & Sons. [4th ed.].
Cited by
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
A High-Frequency Wearable IMU-Based System for Countermovement Jump Assessment
Pousibet-Garrido, A., Benavente, C., Moreno-Pérez, J. A., Pérez-Regalado, S., Carvajal, M. A., Ríos, I. J. C., & Escobedo, P. (2026) · Sensors · doi:10.3390/s26051408 · Cited by 2
“Although a limited number of recent studies have reported high sampling frequencies [26,32,33], these approaches are generally based on multi-sensor configurations or high-end commercial platforms primarily designed for laboratory biomechanical analyses.”
Emerging Trends in Deep Learning and Signal Processing for Wearable Biomedical Signal Analysis
Veeranki, Y. R., & Posada-Quintero, H. F. (2026) · Signals · doi:10.3390/signals7050100
Metadata
- Authors
- Althouse, D., Weeks, C., Spencer, S. B., Park, J., Thompson, B. J., & Louder, T.
- Affiliations
- Utah State University (US)
- University of Colorado Anschutz (US)
- Corresponding author
- Louder, Talin
- Venue
- Signals
- Publisher
- MDPI AG
- Published
- 2025-03-03
- Volume
- 6
- Issue
- 1
- Pages
- 11
- ISSN
- 2624-6120 (ISSN-L)
- OpenAlex
- W4408115957
- Cited by
- 3
- References
- 33
- Citations by year
- 2026: 3
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Signals (publishedVersion, cc-by)
- Digital Commons - USU (Utah State University) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Physical Education and Training Studies
- Keywords
- inertial measurement unit, countermovement jump, jump height, vertical acceleration, take-off velocity, wearable sensors, measurement validity, young adults, sex differences, limb dominance, limb length discrepancy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.