Countermovement jump performance assessment using a wearable 3D inertial measurement unit
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The aim of this study was to validate a wearable inertial measurement unit (IMU), containing a 3D accelerometer and gyroscope, for the estimation of countermovement jump height. The absolute vertical acceleration of the IMU positioned on the back of the participant at L5 level, compensated for trunk rotations, was used to obtain jump height by applying the equation of free-fall to the motion of the IMU. The methodology was tested on 28 participants performing five countermovement jumps each. A reference value for this quantity was obtained using stereophotogrammetry (35.4 cm, s = 4.9). Jump height scores obtained using the proposed methodology (35.9 cm, s = 5.5) presented no significant difference with respect to stereophotogrammetry (P = 0.61). A low bias of 0.6 cm confirmed the accuracy of the estimate, which also showed a high (r = 0.87) and significant (P < 0.0001) correlation with reference values. Furthermore, without compensating accelerations for trunk rotation, jump height was largely underestimated (P < 0.0001) (bias: -12.7 cm) and poorly associated (r = 0.31) with stereophotogrammetry. The results of this study show that the estimation of jump height using inertial sensors leads to accurate results when the measured accelerations are corrected for trunk rotations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
Association of Muscle Power With Functional Status in Community-Dwelling Elderly Women
Foldvari, M., Clark, M., Laviolette, L. C., Bernstein, M. A., Kaliton, D., Castaneda, C., Pu, C. T., Hausdorff, J. M., Fielding, R. A., & Singh, M. A. F. (2000) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/55.4.m192 · Cited by 653
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Cited by
Camomilla, V., Bergamini, E., Fantozzi, S., & Vannozzi, G. (2018) · Sensors · doi:10.3390/s18030873 · Cited by 591
Self-citationCiuti, G., Ricotti, L., Menciassi, A., & Dario, P. (2015) · Sensors · doi:10.3390/s150306441 · Cited by 172
Wearable inertial sensors in swimming motion analysis: a systematic review
Magalhaes, F. A. D., Vannozzi, G., Gatta, G., & Fantozzi, S. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2014.962574 · Cited by 164
Teufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213064 · Cited by 129
Amin Mohammadian, M., Mozayyany, H., Bagheri Koudakani, S., & Maloney, S. J. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112338 · Cited by 5
Metadata
- Authors
- Picerno, P., Camomilla, V., & Capranica, L.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2011-01
- Volume
- 29
- Issue
- 2
- Pages
- 139-146
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2102826848
- Cited by
- 124
- References
- 4
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Countermovement jump performance assessment using a wearable 3D inertial measurement unit. https://app.cochat.ai/papers/10.1080/02640414.2010.523089
- The paper
- Picerno, P., Camomilla, V., & Capranica, L. (2011). Countermovement jump performance assessment using a wearable 3D inertial measurement unit. Journal of Sports Sciences. https://doi.org/10.1080/02640414.2010.523089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.