Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index; 24 of the 46 sources its claims cite were checked for support.
Abstract
BACKGROUND: This study compared energy expenditure (EE), substrate metabolism, and excess post-exercise oxygen consumption (EPOC) during moderate-intensity continuous training (MICT), high-intensity interval training (HIIT), and high-intensity circuit training (HICT) isocaloric sessions. METHODS: Twelve trained male participants completed isocaloric exercise sessions equalized for EE and average power (AP) across the three modalities. Postexercise EE, carbohydrate and lipid oxidation rates, and EPOC were measured 30 and 60 min after training. RESULTS: Total EE and AP during exercise were similar between the protocols. However, EPOC was significantly higher for HIIT (319.0 ± 88.03 mL) and HICT (329.1 ± 27.79 mL) than for MICT (168.5 ± 21.84 mL), demonstrating greater post-exercise metabolic demand in high-intensity protocols. At 30 min post-exercise, carbohydrate oxidation remained elevated in the HIIT (3.70 ± 1.04 mg/kg/min) and HICT (4.06 ± 1.03 mg/kg/min) groups compared to that in the MICT group (1.42 ± 0.58 mg/kg/min), while lipid oxidation rates were also higher (HIIT: 1.08 ± 0.41; HICT: 1.20 ± 0.24 mg/kg/min; MICT: 0.61 ± 0.20 mg/kg/min). These effects persisted for 60 min, with HIIT and HICT maintaining significantly greater carbohydrate and lipid oxidation than MICT. Correlation analysis indicated a strong relationship between carbohydrate oxidation during exercise and lipid oxidation after 60 min of exercise. CONCLUSIONS: High-intensity protocols (HIIT and HICT) promote prolonged postexercise EE, enhance carbohydrate and lipid oxidation, and optimize metabolic recovery, making them effective strategies for maximizing energy utilization beyond the training session.
Overview
CoChat Summary
## TL;DR
In 12 healthy trained men, isocaloric HIIT and HICT produced greater excess post-exercise oxygen consumption (EPOC) and greater post-exercise carbohydrate and lipid oxidation than MICT. The study found no significant differences in total exercise energy expenditure or average power across the three protocols.
## Key findings
- EPOC was significantly higher after HIIT (319.0 ± 88.0 mL O2) and HICT (329.1 ± 83.4 mL O2) than after MICT (168.5 ± 21.84 mL O2); both differences were significant with p = 0.0004 and p = 0.0002, respectively.
- At 30 min post-exercise, carbohydrate oxidation was higher in HIIT (3.70 ± 1.04 mg·kg−1·min−1) and HICT (4.06 ± 1.03 mg·kg−1·min−1) than in MICT (1.42 ± 0.58 mg·kg−1·min−1), and lipid oxidation was also higher in HIIT (1.08 ± 0.41) and HICT (1.20 ± 0.24 mg·kg−1·min−1) than MICT (0.61 ± 0.20 mg·kg−1·min−1).
- At 60 min post-exercise, both HIIT and HICT still showed higher carbohydrate oxidation and higher lipid oxidation than MICT; the paper reports, for example, lipid oxidation of 0.74 mg·kg−1·min−1 (HIIT vs MICT) and 0.90 mg·kg−1·min−1 (HICT vs MICT), both p < 0.0001.
- During exercise, carbohydrate oxidation differed by condition (F(2,22) = 17.67, p = 0.0006, partial η2 = 0.60), with HIIT and HICT both higher than MICT; total exercise EE did not differ significantly between protocols.
## Methods
- Design: Counterbalanced, randomized, crossover, within-participant experiment comparing three isocaloric exercise bouts: MICT, HIIT, and HICT.
- Sample/data: 12 healthy male recreationally HICT-trained participants; all sessions were completed over four visits within seven days, with at least 48 hours between visits.
- Main analysis: VO2 and gas exchange were measured before and for 60 min after exercise; EPOC was estimated from the VO2 recovery curve, substrate oxidation was derived from VO2/VCO2 using stoichiometric equations, and comparisons used ANOVA with Tukey post hoc tests plus Pearson correlations.
## Limitations
- The paper itself says the study was an acute investigation, so any implications for long-term weight management or chronic adaptations are speculative and should be confirmed by longitudinal trials.
- The sample was small (n = 12) and limited to healthy trained men, which makes generalization to women, untrained people, or clinical populations uncertain; this is evident from the sample description.
- The post-exercise window was limited to 60 min, so longer recovery effects were not assessed; this is evident from the methods and outcomes reported.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
17 Valid · 3 Not valid · 20 Not checked · 74 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Post-exercise energy metabolism is closely tied to substrate mobilization during exercise”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 1. Introduction
What the sources say
- Partly supportedcites [8] Jung, 2023, Comparison of energy consumption and excess post-exercise oxygen consumption according to Taekwondo Taegeuk Poomsae performance in Taekwondo players, Phys. Act. Nutr. sourceExperimental — accuracy not yet measured
The Introduction explains that post-exercise oxygen consumption helps reverse exercise-induced metabolic changes, and the Discussion links it to ATP-PCr recovery and lactate removal. These passages support a connection between exercise and post-exercise metabolism, but they do not specifically establish a close tie to substrate mobilization during exercise. (LLM, conf=0.79)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“evidence indicates that high-intensity exercise significantly depletes glycogen reserves, thereby enhancing lipid oxidation during recovery [8].”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 1. Introduction
What the sources say
- Partly supportedcites [8] Jung, 2023, Comparison of energy consumption and excess post-exercise oxygen consumption according to Taekwondo Taegeuk Poomsae performance in Taekwondo players, Phys. Act. Nutr. sourceExperimental — accuracy not yet measured
The Results (page unavailable) report higher fatty-acid oxidation in Taegeuk 4–8 Jangs, and the Discussion says higher exercise intensity is associated with greater post-exercise oxygen consumption. The paper does not report glycogen depletion or establish that depleted glycogen causes increased lipid oxidation during recovery. (LLM, conf=0.82)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“These findings underscore the efficacy of high-intensity training modalities such as HIIT and HICT in enhancing post-exercise EE [29,30].”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 4. Discussion
What the sources say
- Could not verifycites [29] Ulupınar, S., Özbay, S., Gençoğlu, C., Ouergui, I., Öget, F., Kishalı, N.F., Kıyıcı, F., Yılmaz, H.H., and Ardigò, L.P. (2024). Evaluating bioenergetic pathway contributions from single to multiple sprints. Sci. Rep., 14. sourceExperimental — accuracy not yet measured
Ulupınar et al. (2024) studied energy-pathway contributions during repeated sprints in 12 amateur soccer players, not whether HIIT or HICT enhances post-exercise energy expenditure. Its methods use post-exercise oxygen consumption to estimate ATP-PCr contribution, but its results do not report the claimed enhancement. Two paper-scoped searches found no relevant support; the strongest unscoped match scored 0.647, below the threshold for a misattribution finding. The prior disputed verdict is not warranted because the cited paper does not make a contrary claim about post-exercise expenditure. (LLM, conf=0.83)
- Partly supportedcites [30] Queiroz, 2025, Multiple Shorter High-Intensity Interval Exercise Sessions During the Day Result in Greater Energy Expenditure With Less Exertion Than a Longer Single Session: A Randomized Crossover Clinical Trial, Eur. J. Sport Sci. sourceExperimental — accuracy not yet measured
The Results report greater post-exercise energy expenditure after three shorter high-intensity interval exercise sessions than after one longer session, and the Discussion describes HIIT as increasing excess post-exercise oxygen consumption. The paper does not address HICT, so it does not support the claim for both named modalities. Page numbers are unavailable in our copy. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Importantly, despite the suppression of fat oxidation during the exercise itself, recovery metabolism relies heavily on fat utilization, highlighting the significant contribution of lipids to post-exercise energy expenditure [25].”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 4. Discussion
What the sources say
- Partly supportedcites [25] Jiang, L., Zhang, Y., Wang, Z., and Wang, Y. (2024). Acute interval running induces greater excess post-exercise oxygen consumption and lipid oxidation than isocaloric continuous running in men with obesity. Sci. Rep., 14. sourceExperimental — accuracy not yet measured
The Results (Substrate metabolism after HIIT and MICT; page not provided) report that lipids supplied 37.94% of recovery energy after HIIT and 30.09% after MICT, supporting a substantial contribution to post-exercise energy expenditure. The Discussion reports lower fat oxidation during HIIT than MICT, followed by increasing lipid oxidation during recovery. But the claim's broad suggestion that recovery metabolism relies heavily on fat extends beyond these findings in men with obesity, and lipids supplied less than half of recovery energy in both conditions. (LLM, conf=0.85)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This phenomenon is closely linked to excess post-exercise oxygen consumption (EPOC), which is one of the main mechanisms of increased EE after intense activity [29].”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 4. Discussion
What the sources say
- Partly supportedcites [29] Ulupınar, S., Özbay, S., Gençoğlu, C., Ouergui, I., Öget, F., Kishalı, N.F., Kıyıcı, F., Yılmaz, H.H., and Ardigò, L.P. (2024). Evaluating bioenergetic pathway contributions from single to multiple sprints. Sci. Rep., 14. sourceExperimental — accuracy not yet measured
The Calculation of the energy pathway contributions section uses the fast phase of EPOC to estimate energy used in ATP-PCr replenishment during recovery between sprints. That supports a link between EPOC and recovery energy expenditure, but the paper does not establish that EPOC is one of the main mechanisms of increased energy expenditure after intense activity generally. (LLM, conf=0.82)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
74 more claims · 3 with their cited sources checked
Create a free account to see all 114 claims and every source verdict.
- Probably not a substantial claim. 18
- It may state two separate claims as one. 18
- The quote only partly states this claim. 1
Statistics that don’t add up
Each reported p-value recomputed from its test statistic and degrees of freedom.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“t(11) = 4.50, p = 0.0004”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 3. Results > 3.4. Total Substrate Metabolism During MICT, HIIT and HICT
Reported p = .0004 · recomputed p < .001
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“t(11) = 4.61, p = 0.0004”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 3. Results > 3.4. Total Substrate Metabolism During MICT, HIIT and HICT
Reported p = .0004 · recomputed p < .001
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“F(2,22) = 14.39, p < 0.0001”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 3. Results > 3.2. EPOC During MICT, HIIT, and HICT
Reported p < .0001 · recomputed p < .001
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“t(11) = 3.28, p = 0.008”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 3. Results > 3.4. Total Substrate Metabolism During MICT, HIIT and HICT
Reported p = .008 · recomputed p = .007
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“t(11) = 1.16, p = 0.268”
§ Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training > 3. Results > 3.4. Total Substrate Metabolism During MICT, HIIT and HICT
Reported p = .268 · recomputed p = .271
4 more findings
Create a free account to see every finding of this check.
Statistics recomputed
Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.
- Doesn’t add upF(2, 22) = 14.39reported p < .0001 · recomputed p < .001
“F(2,22) = 14.39, p < .0001”
- Doesn’t add upt(11) = 5.27reported p < .0001 · recomputed p < .001
“t(11) = 5.27, p < .0001”
- Doesn’t add upF(2, 22) = 8.24reported p < .0001 · recomputed p = .002
“F(2,22) = 8.24, p < .0001”
- Doesn’t add upt(11) = 5.64reported p < .0001 · recomputed p < .001
“t(11) = 5.64, p < .0001”
- Doesn’t add upt(11) = 4.94reported p = .0003 · recomputed p < .001
“t(11) = 4.94, p = .0003”
35 more recomputed tests
Create a free account to see every test the Stats check recomputed.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Self-check results appear here once an independent check has confirmed them.
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603 · cited 1×
“EE, which is the EE induced by an exercise bout (e.g., exercise EE–resting EE), was calculated individually from VO 2 and VCO 2 in L · min − 1 using the Weir Equation [18]: In addition, EE was calculated individually for the 60 min recovery period.”
Obesity: global epidemiology and pathogenesis
Blüher, M. (2019) · Nature Reviews Endocrinology · doi:10.1038/s41574-019-0176-8 · Cited by 5,126
Chooi, Y. C., Ding, C., & Magkos, F. (2019) · Metabolism · doi:10.1016/j.metabol.2018.09.005 · Cited by 2,737 · cited 1×
“Since 1980, there has been an increased global focus on strategies for effective weight loss and long-term weight maintenance, given the challenges faced by approximately one-third of the global population in achieving sustainable body weight management [1].”
Sample size determination and power analysis using the G*Power software
Kang, H. (2021) · Journal of Educational Evaluation for Health Professions · doi:10.3352/jeehp.2021.18.17 · Cited by 2,572 · cited 1×
“An a priori sample size calculation (effect size = 0.92; 1 − β = 0.80; α = 0.05; nonsphericity correction = 1.0) using G*Power indicated that 12 participants would be adequate to achieve statistical power [15].”
InfluentialSkeletal muscle energy metabolism during exercise
Hargreaves, M., & Spriet, L. L. (2020) · Nature Metabolism · doi:10.1038/s42255-020-0251-4 · Cited by 1,408 · cited 1×
“The greater disruption of homeostasis induced by high-intensity workouts also leads to increased hormonal responses, such as elevated catecholamine levels, which further enhances the metabolic rate during recovery [28].”
Monitoring training in athletes with reference to overtraining syndrome
FOSTER, C. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199807000-00023 · Cited by 1,229 · cited 1×
“The scale has mode-specific verbal and pictorial descriptors in numerical responses and a narrow range from 0 (extremely easy) to 10 (extremely difficult), as described by Foster [20].”
Table of nonprotein respiratory quotient: an update.
Péronnet, F., & Massicotte, D. (1991) · PubMed · Cited by 1,209
Effect of Exercise Intensity, Duration and Mode on Post-Exercise Oxygen Consumption
B??rsheim, E., & Bahr, R. (2003) · Sports Medicine · doi:10.2165/00007256-200333140-00002 · Cited by 466
Regulation of glucose and glycogen metabolism during and after exercise
Jensen, T. E., & Richter, E. A. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.224972 · Cited by 274 · cited 2×
“This process involves an increase in oxygen consumption and metabolic rate, increasing EPOC, and prolonging EE after exercise [31].”
Understanding the factors that effect maximal fat oxidation.
Purdom, T., Kravitz, L., Dokladny, K., & Mermier, C. (2018) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-018-0207-1 · Cited by 247
Research works printed but not linked: 1
- Feingold, K.R., Ahmed, S.F., Anawalt, B., Blackman, M.R., Boyce, A., Chrousos, G., Corpas, E., de Herder, W.W., Dhatariya, K., and Dungan, K. (2023, April 02). Control of Energy Expenditure in Humans. [Updated 2022 Mar 21], Endotext [Internet], Available online: https://www.ncbi.nlm.nih.gov/books/NBK278963.
Cited by
Ariffin, N. H. C. M., Fauzi, N. F. M., Yusof, H. A., Aziz, A. R., Nosaka, K., & Muhamed, A. M. C. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06178-w
“…that high-intensity exercise protocols elicit prolonged post-exercise energy expenditure alongside increased carbohydrate and fat oxidation (Faleiro et al. 2025 ), likely reflecting heightened mitochondrial respiration, substrate turnover, and metabolic recovery processes during early…”
Zhang, Z., Liu, C., Liu, T., & Xie, Y. (2026) · PLoS ONE · doi:10.1371/journal.pone.0354592
“The reduction in body fat may be partly related to the high energy demand of interval-and circuit-based training, including increased post-exercise oxygen consumption and lipid oxidation [33].”
Gao, Z., Han, Y., Wang, Y., Cheng, Z., Xiang, Z., & Han, Y. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1929244
Metadata
- Authors
- Faleiro, V., Gurgel, A. V., Guimarães, T. T., Figueiredo, T. C., Teixeira, F. G., Jotta, B., Monteiro, E. R., Meirelles, A. G., Caldas, C. C. A., de Almeida, M. T., Castiglione, R. C., & Marques-Neto, S. R.
- Affiliations
- Universidade Salgado de Oliveira (BR)
- Estácio (Brazil) (BR)
- University Center Augusto Motta (BR)
- Graduate Program in Rehabilitation Science (PPGCR/UNISUAM), Centro Universitário Augusto Motta, Rio de Janeiro 21032-060, Brazil
- Programa de Pós-graduação em Ciências da Atividade Física, Universidade Salgado de Oliveira (UNIVERSO), Niterói 24030-060, Brazil
- Universidade do Estado do Rio de Janeiro (BR)
- ORCID
- Venue
- Sports
- Publisher
- MDPI AG
- Published
- 2025-10-06
- Volume
- 13
- Issue
- 10
- Pages
- 355
- ISSN
- 2075-4663 (ISSN-L)
- PMC
- PMC12567725
- OpenAlex
- W4414874153
- Cited by
- 4
- References
- 35
- Citations by year
- 2026: 4
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Keywords
- high-intensity interval training, circuit training, moderate-intensity continuous training, excess post-exercise oxygen consumption, energy expenditure, substrate oxidation, carbohydrate oxidation, lipid oxidation, trained men
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training. https://app.cochat.ai/papers/10.3390/sports13100355
- The paper
- Faleiro, V., Gurgel, A. V., Guimarães, T. T., Figueiredo, T. C., Teixeira, F. G., Jotta, B., Monteiro, E. R., Meirelles, A. G., Caldas, C. C. A., de Almeida, M. T., Castiglione, R. C., & Marques-Neto, S. R. (2025). Isocaloric High-Intensity Interval and Circuit Training Increases Excess Post-Exercise Oxygen Consumption and Lipid Oxidation Compared to Moderate-Intensity Continuous Training. Sports. https://doi.org/10.3390/sports13100355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.